GPSEMI GC89SR Bar clamp for hockey puk device Datasheet

Phone: +39-010-659 1869
Fax: +39-010-659 1870
Web: www.gpsemi.it
E-mail: [email protected]
Green Power Solutions srl
Via Greto di Cornigliano 6R - 16152 Genova , Italy
GC89…R
BAR CLAMP FOR HOCKEY PUK DEVICES
Clamping total thikness of assembly from
11mm to 119mm
Pre-loaded to the specific clamping
force (12 ÷ 24 kN)
Maximum device diameter: 76mm
Surface passivation to provide extra protection
Hexagon head bolt partially
threaded M8x1.25, UNI5737, 8.8 steel
Various lengths of bolts and insulators
Round shaped clamping head for optimal clamping
force application
Four styles available
User friendly clamping force indicator
UL94 certified insulation material
Parameter
Weight
Clamping Force*
Unit
g
kN
Types
Testing conditions
Values
Notes
Min
GC89S…R
GC89B…R
730
1120
12
GC89…16R
16
GC89…20R
GC89…24R
20
24
*
± 10%
VRMS
1 min
3000
Insulating Material
Noryl  ∗∗
UL File
E121562
Max. working temperature
°C
Creepage distance:
mm
Clearance distance:
mm
Storage temperature
°C
Flammability
110
-30
28
20.3
110
-40
mm
UL94 V-1 Flame class rating
1.5
mm
UL94 V-0 Flame class rating
8.00
mm
CSA Flammability
1.00
Other clamping forces available: contact factory

** Noryl is a registered trade mark of General Electric
Document GC89…RT001
Max
860
1290
GC89…12R
Clamping Force tolerance
Insulation Voltage
Typ
GC89…R
BAR CLAMP FOR HOCKEY PUK DEVICES
ORDERING INFORMATION TABLE
GC89
Clamps can be ordered using the following part numbering system
(1) Construction type:
B
N
B
A
20
(1)
(2)
(3)
(4)
(5)
R
B = with double bar
S = with single bar
(2) Insulator position:
N = upper side
(3) Insulator code:
(4) Bolt code:
(5) Clamping force (in kN):
see table below
R = lower side
K
K
see table below
12
16
20
24
(6) Special accessories
blank = no accessories
S = extra bar spacer
D = pressure disc in place of
pressure bar
K: Total thickness of the assembly to be clamped
For thicknesses S' Min < K < S Min an additional 4mm thick bar spacer is needed (see list of special accessories)
Type GC89BN…R: suggested insulator/bolt types
Allowed clearance S
Insulator choice
Bolt choice
Max height
S' Min [mm]**
S Min [mm]
S Max [mm]
(3)
Ins. Length [mm]
(4)
Bolt Length [mm]
11
15
30
A
50
Z
100
115
21
25
40
A
50
A
110
125
31
35
50
B
70
B
120
135
41
45
60
B
70
C
130
145
51
55
70
C
95
D
140
155
61
71
65
75
80
90
C
C
95
95
E
F
150
160
165
175
T [mm]
** with additional bar spacer only
Type GC89BR…R: suggested insulator/bolt types
Allowed clearance S
Insulator choice
Max height
3
Bolt choice
S' Min [mm]**
S Min [mm]
S Max [mm]
(3)
Ins. Length [mm]
(4)
Bolt Length [mm]
11
15
30
A
50 ***
Z
100
129
21
25
40
A
50
A
110
139
31
35
50
A
50
B
120
149
41
45
60
B
70
C
130
159
51
55
70
B
70
D
140
169
61
71
65
75
80
90
B
C
70
95
E
F
150
160
179
189
** with additional bar spacer only
T [mm]
*** For S Max
Type GC89SN…R: suggested insulator/bolt types
Allowed clearance S
Insulator choice
Bolt choice
Max height
S Min [mm]
S Max [mm]
(3)
Ins. Length [mm]
(4)
Bolt Length [mm]
T [mm]
20
24
39
A
50
Z
100
110
30
34
49
B
70
A
110
120
40
44
59
B
70
B
120
130
50
54
69
C
95
C
130
140
60
64
79
C
95
D
140
150
70
80
74
84
89
99
C
D
95
120
E
F
150
160
160
170
4
S' Min [mm]**
** with additional bar spacer only
Type GC89SR…R: suggested insulator/bolt types
Allowed clearance S
Insulator choice
Bolt choice
Max height
S' Min [mm]**
S Min [mm]
S Max [mm]
(3)
Ins. Length [mm]
(4)
Bolt Length [mm]
T [mm]
40
44
59
B
70
Z
100
129
50
54
69
B
70
A
110
139
60
64
79
B
70
B
120
149
70
74
89
C
95
C
130
159
80
84
99
C
95
D
140
169
90
100
94
104
109
119
D
D
120
120
E
F
150
160
179
189
** with additional bar spacer only
Document GC89…RT001
S
(6)
GC89…R
BAR CLAMP FOR HOCKEY PUK DEVICES
BAR CLAMP OUTLINES
115
T
Ø12
50 up to 120
Ø12
43
77
14
20
29
4
S
77
S
T
24.5
63
20
20
24.5
50 up to 120
14
115
25
89
25
89
GC89BN...R
GC89BR...R
115
89
77
25
89
25
GC89SN...R
GC89SR...R
Dimensions in mm - Tolerances according to ISO 2768 MK
Document GC89…RT001
S
Ø12
14
50 up to 120
T
22 Min.
S
Ø12
77
T
24.5
20
20
24.5
50 up to 120
14
115
GC89…R
BAR CLAMP FOR HOCKEY PUK DEVICES
S' Min
S Max
OPTIONAL BAR SPACER
S Min
PRESSURE DISC
SPECIAL ACCESSORIES
The following special accessories are available on request (see ordering information table)
Bar spacer
4
Ø13
25
115
Ø24
4
Pressure disc
Useful for grooved heatsink
Suggested groove diameter 27mm +/- 0.5
Dimensions in mm - Tolerances according to ISO 2768 MK
In the interest of product improvement Green Power Solutions reserves the right to change any specification given in this data sheet without
notice.
Document GC89…RT001
Similar pages