Mean Well LRS-350-15 350w single output switching power supply Datasheet

350W Single Output Switching Power Supply
■ Features
AC input range selectable by switch
Withstand 300VAC surge input for 5 second
Protections: Short circuit / Overload / Over voltage /
Over temperature
Forced air cooling by built-in DC fan
Built-in cooling Fan ON-OFF control
1U low profile
Withstand 5G vibration test
LED indicator for power on
No load power consumption<0.75W
100% full load burn-in test
High operating temperature up to 70℃
Operating altitude up to 5000 meters (Note.8)
High efficiency, long life and high reliability
3 years warranty
LRS-350
series
■ Applications
Industrial automation machinery
Industrial control system
Mechanical and electrical equipment
Electronic instruments, equipments or
apparatus
■ Description
LRS-350 series is a 350W single-output enclosed type power supply with 30mm of low profile design. Adopting
the input of 115VAC or 230VAC (select by switch), the entire series provides an output voltage line of 3.3V,
4.2V, 5V, 12V, 15V, 24V, 36V and 48V.
In addition to the high efficiency up to 89%, with the built-in long life fan LRS-350 can work under -25~
+70℃ with full load. Delivering an extremely low no load power consumption (less than 0.75W), it allows
the end system to easily meet the worldwide energy requirement. LRS-350 has the complete protection
functions and 5G anti-vibration capability; it is complied with the international safety regulations such as
UL60950-1. LRS-350 series serves as a high price-to-performance power supply solution for various
industrial applications.
■ Model Encoding
LRS - 350 - 3.3
Output voltage
Output power
Series name
File Name:LRS-350-SPEC 2015-12-31
LRS-350
350W Single Output Switching Power Supply
series
SPECIFICATION
LRS-350-3.3
LRS-350-4.2 LRS-350-5
LRS-350-12
LRS-350-15 LRS-350-24 LRS-350-36 LRS-350-48
DC VOLTAGE
3.3V
4.2V
5V
12V
15V
24V
36V
48V
RATED CURRENT
60A
60A
60A
29A
23.2A
14.6A
9.7A
7.3A
CURRENT RANGE
0 ~ 60A
0 ~ 60A
0 ~ 60A
0 ~ 29A
0 ~ 23.2A
0 ~ 14.6A
0 ~ 9.7A
0 ~ 7.3A
RATED POWER
198W
252W
300W
348W
348W
350.4W
349.2W
350.4W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
3.6 ~ 4.4V
4.5 ~ 5.5V
10.2 ~ 13.8V 13.5 ~ 18V
VOLTAGE TOLERANCE Note.3 ±4.0%
±4.0%
±3.0%
±1.5%
±1.0%
±1.0%
±1.0%
±1.0%
LINE REGULATION Note.4 ±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
LOAD REGULATION Note.5 ±2.5%
±2.5%
±2.0%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
88.5%
89%
MODEL
OUTPUT
INPUT
SETUP, RISE TIME
1300ms, 50ms/230VAC
HOLD UP TIME (Typ.)
16ms/230VAC
VOLTAGE RANGE
90 ~ 132VAC / 180 ~ 264VAC by switch
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
79.5%
AC CURRENT (Typ.)
6.8A/115VAC
INRUSH CURRENT (Typ.)
60A/115VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVER LOAD
PROTECTION
2.97 ~ 3.6V
OVER VOLTAGE
OVER TEMPERATURE
FAN ON/OFF CONTROL
FUNCTION (Typ.)
21.6 ~ 28.8V 32.4 ~ 39.6V 43.2 ~ 52.8V
1300ms,50ms/115VAC at full load
12ms/115VAC at full load
81.5%
240 ~ 370VDC
85%
83.5%
(switch on 230VAC)
86%
88%
3.4A/230VAC
60A/230VAC
110 ~ 140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V
4.6 ~ 5.4V
5.75 ~ 6.75V 13.8 ~ 16.2V 18 ~ 21V
28.8 ~ 33.6V 41.4 ~ 46.8V 55.2 ~ 64.8V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
RTH3≧50℃ FAN ON, ≦40℃ FAN OFF
WORKING TEMP.
-25 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
SAFETY
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH
MTBF
OTHERS DIMENSION
PACKING
NOTE
327.9K hrs min.
MIL-HDBK-217F (25℃)
215*115*30mm (L*W*H)
0.76Kg; 15pcs/12.4Kg/0.78CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up
time.
7.The 150% peak load capability is built in for up to 1 second for 12~48V.LRS-350 will enter hiccup mode if the peak load is delivered
for over 1 second and will recover once it resumes to the rated current level(115VAC/230VAC).
8. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft).
File Name:LRS-350-SPEC 2015-12-31
LRS-350
350W Single Output Switching Power Supply
series
Block Diagram
RECTIFIERS
&
FILTER
115/230V(SW)
fosc : 65KHz
FAN
FAN ON/OFF CONTROL
EMI
FILTER
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
RECTIFIERS
+V
-V
O.T.P.
O.V.P.
FG
PWM
CONTROL
O.L.P.
Derating Curve
DETECTION
CIRCUIT
Static Characteristics
100
100
90
80
70
LOAD (%)
LOAD (%)
60
40
20
-25
180 ~ 264VAC
90 ~ 132VAC
80
60
50
40
-20
-10
0
10
20
30
40
AMBIENT TEMPERATURE (℃)
50
60
70
(HORIZONTAL)
90
180
95
190
100
200
105
210
110
220
115
230
120
240
125
250
132
264
INPUT VOLTAGE (VAC) 60Hz
File Name:LRS-350-SPEC 2015-12-31
LRS-350
350W Single Output Switching Power Supply
Mechanical Specification
Case No.207A
series
Unit:mm
215
32.5
150
36.7
LED
+V
ADJ.
9
4-M4 L=3mm
7
50
6
115
133
9.5
8
5
47.45
8
4
3
32.5
2
16
1
15
150
32.5
Terminal Pin No. Assignment :
6.5 6.5
12.5
30
12.8 6.9
2
Air flow
direction
4-M4(Both Sides) L=5mm
Pin No.
1
2
3
Assignment
AC/L
AC/N
FG
Pin No.
Assignment
4~6
DC OUTPUT -V
7~9
DC OUTPUT +V
Installation Manual
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html
File Name:LRS-350-SPEC 2015-12-31