GreenTech EC tubeaxial fans Ø 119 x 38 mm Possible special versions: - Speed signal - PWM speed control - Analog speed control - Moisture protection - Salt spray protection - Degree of protection: IP 65 - Compliance for use in systems with flammable refrigerant charge up to 150 g -40...+75 65,000 / 25,000 110,000 1 25 4.1 1.7 1,850 -40...+75 65,000 / 25,000 110,000 2 39 5.2 3.8 3,000 -40...+75 65,000 / 25,000 110,000 3 90...264 43 5.5 4.4 3,300 -40...+75 65,000 / 25,000 110,000 4 50 / 60 90...264 43 5.5 4.5 3,300 -40...+75 65,000 / 25,000 110,000 8 100...240 50 / 60 90...264 43 5.5 4.5 3,300 -40...+75 65,000 / 25,000 110,000 8 59 230 50 / 60 195...265 25 4.1 1.7 1,850 -40...+75 65,000 / 25,000 110,000 5 86 230 50 / 60 195...265 36 4.9 2.8 2,700 -40...+75 65,000 / 25,000 110,000 6 160 94 230 50 / 60 195...265 39 5.1 3.2 3,000 -40...+75 65,000 / 25,000 110,000 7 175 103 230 50 / 60 195...265 43 5.5 4.4 3,300 -40...+75 65,000 / 25,000 110,000 8 ACi4410HH 175 103 115 50 / 60 85...132 43 5.5 4.4 3,300 -40...+75 65,000 / 25,000 110,000 8 Subject to change * analog (5-10 VDC) speed control input, IP 65 VAC Hz VAC dB(A) Bel(A) 78 46 100...240 50 / 60 90...264 23 ACi4400MLR*** 100 59 100...240 50 / 60 90...264 ACi4400H 160 94 100...240 50 / 60 90...264 ACi4400HH 175 103 100...240 50 / 60 ACi4400HHAU* 175 103 100...240 ACi4400/2HHP** 175 103 ACi4420ML 100 ACi4420N 147 ACi4420H ACi4420HH ACi4400L ** PWM speed control input and 2ppr, open collector tach output *** moisture protection Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 10302 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/ general conditions 5 6 7 8 Rotor protrusion max. 0.6 mm. Curve 1,500 cfm Type Life ecpectancy L10IPC (40 °C) Temperature range 1.1 m3/h Nominal Data Service life L10 (Tmax) ebm-papst standard Nominal speed 3.7 Sound power level Hours Sound pressure level Hours Voltage range °C Frequency rpm-1 Nominal voltage Watts Air flow / Air flow Power consumption Service life L10 (40 °C) ebm-papst standard (1) Fiberglass-reinforced plastic Sintec sleeve bearings Ball bearings Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, looking towards rotor Connection: with 2 flat pins 2.8 x 0.5 (not with IP65) optional flying leads Highlights: Fully integrated converter and fan electronics. ACi4400 models are universally usable for all main voltages between 90 and 264 VAC. Compact design and lightweight. Weight: 275 g