Hirose MF17S-WPS01-0400 Harsh environment fiber optic connector Datasheet

Harsh Environment Fiber Optic Connectors
MU
MF 14 and MF 17 Series
SC
FC
Harsh
Environment
■Features
1. 2 Fibers (MF14 series), 4 Fibers (MF17 series), or Optical/Electrical Hybrids are available.
6 fibers (MF22 series) available.
2. Incorrect Insertion Prevention.
Guide key (plug) and key slot (receptacle) are designed for prevent incorrect insertion.
Attenuators
3. Plug, receptacle fully mated condition satisfy IP67 wateroof Performance.
4. For more than 10 years, MF series has been designed and installed in many harsh
environmental applications.
Please contact us if you have any requests.
HIROSE will offer excellent solutions to meet your requirements.
■Applications
Terminators
Outdoor optical transmission systems, LAN, CATV, ATM, Base station, industrial optical/electric lines.
55
■Product Specifications
Ratings
Operating temperature range
FC
Environmental
characteristics
SC
Mechanical
characteristics
Optical
characteristics
MU
Item
-25°C to +70°C
Storage temperature range
Test Method
Insertion Loss
Wavelength 1310nm (LD)
Durability
(cycles, mating/un-mating)
100 times
Vibration
Frequency: 10 to 55 Hz, single amplitude of 0.75 mm,
acceleration of 98.1m/s2, 2 hours in each of the 2 axis.
Shock
Acceleration of 981 m/s2, 6 ms duration, sine halfwave waveform, 3 cycles in each of the 2 axis.
Humidity
(Temperature/ humidity- cycles)
-10°C to 65°C, humidity: 90% to 96% 10 cycles
Change of temperature
-40°C to +75°C 42 cycles
Dry heat
960 hours at 85°C
Specifications
1.0dB max. (Note)
1) Insertion loss fluctuation after (test) : 0.3dB max.
2) No visible damage, dislocation of clamp or cable.
1) Insertion loss fluctuation after test: 0.3dB max.
2) No visible damage, dislocation of clamp or cable.
Cold
960 hours at -40°C
Salt Mist
1000 hours in a 5% concentration of salt mist
No visible corrosion.
Waterproof
Inside air pressure 4.90kPa for one minute
No air bubble leakege, IP67
Note: Insertion loss herein means only connection loss.
Attenuators
Harsh
Environment
■Materials
Part
Material
Plug and Receptacle Housing
Aluminum alloy
Ferrule case
Synthetic resin
Strain relief
Zinc alloy
Protective cap and clamp
Brass
Rubber boot and O-rings
Synthetic rubber
Screws, springs, and steel wire
Stainless steel
Washer
Brass
Split sleeve
Zirconia or Copper alloy
■ Important Notice
Terminators
1. Please ask HIROSE when you assemble the MF connectors for special cables.
Some cables can not be used for the connectors.
2. MF series use SC/PC zirconia ferrules. Please see page 33.
56
-25°C to +70°C
■Bayonet lock
●Plug Housing
C
ØD
ØA
MU
B
SC
E
Part Number
Number of Fibers
ØA
B
C
ØD
E
MF14B-WP*S01-0200
2
24
184.7
69
24
21
MF17B-WP*S01-0400
4
27
116.5
52
27
21
* indicates cable diameter. 8, 9 and 10mm, diameter cables are appicable.
C
●Square Flange Receptacle Housing
ME
B
3
A
ØD
FC
.3
Ø3
Harsh
Environment
ØF
4-
G
Part Number
Number of Fibers
MA
B
C
ØD
ME
ØF
G
MF14B-WRF01-0200
2
30
10
45.5
20.5
23
24
18.7
MF17B-WRF01-0400
4
35
10
51.5
25.5
27
27
18.7
Note: Up to 3 mm cables are applicable.
ØD
C
3
A
E HEX
B
Attenuators
●Bulk Head Receptacle Housing
ØF
Terminators
G
Part Number
Number of Fibers
MA
B
C
ØD
ME
ØF
G
MF14B-WRB01-0200
2
30
17.5
45.5
20.5
28
24
18.7
MF17B-WRB01-0400
4
34
17.5
51.5
25.5
32
27
18.7
Note: Up to 3 mm cables are applicable.
57
■Threaded lock
●Plug housing
C
ØA
MU
B
SC
ØD
F
E
Part Number
Number of Fibers
ØA
B
C
ØD
E
F
MF14S-WP*S01-0200
2
24
184.7
69
24
20.8
M20∞1
MF17S-WP*S01-0400
4
27
116.5
52
27
20.8
M22∞1
*indicates the cable diameter. 8, 9 and 10mm, diameter cables are applicable.
C
●Square Flange Receptacle Housing
MF
B
3
ØD
MA
FC
E
.3
Ø3
Harsh
Environment
ØG±0.3
4-
H
Part Number
Part Number
MA
B
C
ØD
E
MF
ØG
H
MF14S-WRF01-0200
2
30
10
45.5
20.5
M20∞1
23
24
18.5
MF17S-WRF01-0400
4
35
10
51.5
25.5
M22∞1
27
27
18.5
Attenuators
Note: Up to 3 mm cables are applicable.
●Bulk Head Receptacle Housing
C
3
A
ØD
B
ØG
Terminators
F HEX
E
H
Part Number
Part Number
MA
B
C
ØD
E
MF
ØG
H
MF14S-WRB01-0200
2
31
17.5
45.5
20.5
M20∞1
30
24
18.5
MF17S-WRB01-0400
4
34
17.5
51.5
25.5
M22∞1
32
27
18.5
Note: Up to 3 mm cables are applicable.
58
BPanel cut-out
●Square Flange Receptacle
MU
ØA
Ø3
.3
MB
A
B
21
23
MF14S-WRF01-0200
21
23
MF17B-WRF01-0400
26
27
MF17S-WRF01-0400
26
27
SC
4-
Part Number
MF14B-WRF01-0200
Panel thickness: 2mm to 4.5mm
●Bulk Head Receptacle
Harsh
Environment
B
FC
ØA
Panel thickness: 2mm to 4.5mm
Part Number
A
B
MF14B-WRB01-0200
22.2
21.2
MF14S-WRB01-0200
24.2
23.2
MF17B-WRB01-0400
24.2
23.2
MF17S-WRB01-0400
24.2
23.2
Attenuators
Terminators
59
Harsh Environment Fiber Optic Connector
MU
MF22 Series
SC
FC
Harsh
Environment
■Features
Receptacles
1. 6 Fibers or Optical /Electric Hybrids are
available
2 fibers (MF14), 4fibers (MF17) available.
Please contact us if you have any requests.
HIROSE will offer excellent solutions to meet your requirements.
Guide key slot
1
6
2
5
Five guide keys positioned at specific angles assure that the
connector will mate only with the corresponding assembly.
Attenuators
2. Incorrect Insertion Prevention
3
4
3. Plug, receptacle fully mated condition satisfy
IP67 waterproof performance.
4. Harsh environment applications
The connector’s outer surfaces are covered with heat
baked hard coating and all internal connections are
protected by seals.
Plugs
Terminators
Guide key
5. Cable Termination
The connector will terminate with a majority of cables having
outside diameter from 7mm to 12mm.
Please contact Hirose for other applicable cable.
1
6
2
5
3
■Applications
4
Outdoor optical transmission systems, LAN, CATV, ATM,
and other applications requiring environmentally protected
optical or electrical connections.
61
■Product Specifications
Ratings
Operating temperature range
FC
Environmental
characteristics
SC
Mechanical
characteristics
Optical
characteristics
MU
Item
-40°C to +75°C
Storage temperature range
Test Method
Insertion Loss
Wavelength 850nm (LD)
Durability
(cycles, mating/un-mating)
500 times
Vibration
Frequency: 10 to 55 Hz, single amplitude of 0.75 mm,
acceleration of 98.1m/s2, 2 hours in each of the 2 axis.
Shock
Acceleration of 981 m/s2, 6 ms duration, sine halfwave waveform, 3 cycles in each of the 2 axis.
Humidity
(Temperature/ humidity- cycles)
-10°C to 65°C, humidity: 90% to 96% 10 cycles
Change of temperatice
-40°C / +75°C 42 cycles
Dry heat
336 hours at 85°C
Specifications
0.7dB max. (Note)
1) Insertion loss fluctuation (after test): 0.3dB max.
2) No visible damage, dislocation of clamp or cable.
1) Insertion loss fluctuation after test: 0.3dB max.
2) No visible damage, dislocation of clamp or cable.
Cold
240 hours at -40°C
Salt mist
1000 hours in a 5% concentration of salt mist
No visible corrosion.
Waterproof
Inside air pressure 4.90kPa for one minute
No air bubble leakege, IP67
Note: Insertion loss herein means only connection loss.
Attenuators
Harsh
Environment
■Materials
Part
Material
Plug and Receptacle Housing
Aluminum alloy
Ferrule case
Synthetic resin
Strain relief components
Zinc alloy
Protective cap and clamp
Synthetic resin
Rubber boot and O-rings
Synthetic rubber
Screws, springs, and ball chain
Stainless steel
Washer
Brass
Split sleeve
Zirconia or Copper alloy
■ Important Notice
Terminators
1. Please ask HIROSE when you assemble the MF connectors for special cables.
Some cables can not be used for the connectors.
2. MF series use SC/PC zirconia ferrules. Please see page 33.
62
-40°C to +85°C
■Threaded lock
●Plug housing
MU
Ø34
126
121
Tr30∞2
SC
Part Number
Number of Fibers
MF22S-WDP*S01-0600
6
*indicates cable diameter.
●Bulk head receptacle housing
FC
BPanel cut-out
4
5
33 +0.5
0
Ø32
2
3
1
6
43
42 HEX
43
Ø34 +0
0
Ø4
.5
5
20
32.35
Harsh
Environment
Tr30∞2
Panel thickness: 1mm to 4mm
Part Number
Number of Fibers
Attenuators
MF22S-WDRB01-0600
6
Note: Up to 3 mm cables are applicable.
Terminators
63
■Tools
SC
MU
●Plug assembly tool
Part Number
CL No.
MF22S-T2
709-0065-0
Part Number
CL No.
HSC-T3
704-0287-0
Terminators
Attenuators
Harsh
Environment
FC
●Crimp tool for receptacle assembly
64
Similar pages