Embedded Power for Business-Critical Continuity Rev. 07.23.07 LPS60-M Series 1 of 3 LPS60-M Series 60 Watts RoHS Medical Total Power: Input Voltage: # of Outputs: 60 - 80 Watts 85 - 264 VAC 120 - 300VDC Single Electrical Specifications Special Features • • • • • • • • • • Medical safety approvals Universal input 3" x 5" footprint Remote sense Built in EMI filter Low output ripple Adjustable output voltage Overload protection 110 KHz switching frequency LPX60 enclosure kit available Input Input range 85 - 264 VAC (wide range) 120 - 300VDC Frequency 47-440 Hz Inrush current Input current <18A peak @ 115VAC, <36A peak @230 VAC, cold start @ 25°C 1.5A max. (RMS) @ 115 VAC Efficiency 70% typical at full load EMI filter FCC Class A conducted; CISPR22 Class A conducted; EN55022 Class A conducted; VDE0878 PT3 Class A conducted Safety ground leakage current <75μA @ 50/60Hz; 264VAC input Output Maximum power Adjustment range 60W for convection; 80W with 30CFM forced air -5, +10% minimum Hold-up time 20ms @ 60W load, 115VAC nominal line Overload protection Safety VDE UL CSA CE 0750/EN60950 (IEC601) 21310-3336-0015 UL2601 E182560 CSA 22.2 No.601.1 LR109492 Mark (LVD) Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating Overvoltage protection 5V output; 5.7 - 6.7VDC. Other outputs 10% to 25% above nominal output Remote sense Compensates for 0.5V lead drop min. Will operate without remote sense connected. Reverse connection protected. Rev. 07.23.07 LPS60-M Series 2 of 3 Environmental Specifications Operating temperature: 0° to 50°C ambient derate each output as 2.5% per degree from 50° to 70°C, -20°C startup Storage temperature: -40°C to +85°C Electromagnetic susceptibility: Humidity: Power Derating Curve 80W 30 CFM Forced Air Cooling designed to meet IEC801, -2, -3, -4, -5, -6, Level 3 Operating; non-condensing 5% to 95% RH Vibration: Three orthogonal axes, sweep at 1cot/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz, operational Temperature coefficient ±0.04% per °C MTBF demonstrated >550,000 hours at full load and 25°C ambient conditions Output Power (Watts) 60W 40W Natural Convection Cooling 20W 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C TA – Ambient Temperature – °C 0.22" (5.6) M2 GND SK201 3.00" (76.2) 1 2 3 4 5 6 2.55" (64.8) SK 1 1 N 3 L 4.56" (115.8) 0.22" (5.6) 1.69" (42.9) 0.12" (3) _+ Remote Sense Connector Voltage Adj. Pot SK 2 0.15" (4) DIA (4 places) 5.00" (127) 30W 0W Mechanical Drawing M1 40W Embedded Power for Business-Critical Continuity Ordering Information Americas LPS63-M 12V 0A 5A 6.7A 7.5A ±2% 120mV LPS64-M 15V 0A 4A 5.3A 6A ±2% 150mV 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 LPS65-M 24V 0A 2.5A 3.3A 3.8A ±2% 240mV Europe (UK) Model Number Maximum Load Minimum with Convection Load Cooling Output Voltage Maximum Load with 30CFM forced Air Peak Regulation2 Load1 Ripple P/P (PARD)3 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10μF (tantalum capacitor) in parallel with a 0. μF capacitor at rated line voltage and load ranges. Rev. 07.23.07 LPS60-M Series 3 of 3 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) Pin Assignments Connector LPS62-M LPS63-M LPS65-M SK1-1 SK1-3 Neutral Line Neutral Line Neutral Line SK2-1 SK2- 2 SK2- 3 SK2-4 SK2-5 SK2-6 SK201-1 SK201-2 +12V +12V +12V Common Common Common +Sense -Sense +15V +15V +15V Common Common Common +Sense -Sense +24 +24 +24 Common Common Common +Sense -Sense Mating Connectors AC Input: DC Outputs: Molex 09-50-8031 (USA) Not required for (-T) option 09-91-0300 (UK) PINS: 08-58-0111 Molex 09-50-8061 (USA) Not required for (-T) option 09-91-0600 (UK) PINS: 08-52-0113 Remote Sense: Molex 22-01-2025 PINS: 08-52-0113 Astec Connector Kit #70-841-006, includes all of the above 1. 2. Specifications subject to change without notice. All dimensions in inches (mm), tolerance is ±0.02" (±0.5mm) 3. 4. 5. Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is safety ground connection. Specifications are for convection rating at factory settings at 115 VAC input, 25°C unless otherwise stated. 6. 7. Warranty: 2 year Weight: 0.75lbs/0.34kg 16th - 17th Floors, Lu Plaza 2 Wing Yip Street, Kwun Tong Kowloon, Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.astecpower.com www.artesyn.com [email protected] [email protected] While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2007 Emerson Electric Co.