CLARE LCA127LSTR Single pole optomos relay Datasheet

LCA127L
SINGLE POLE OptoMOS Relay
Load Voltage
Load Current
Max RON
LCA127L
250
200
10
Description
LCA127L is a 250V, 200mA, 10W 1-Form-A relay. It features low on-resistance.
Units
V
mA
Ω
Features
• Small 6 Pin DIP Package
• Low Drive Power Requirements (TTL/CMOS
Compatible)
• No Moving Parts
• High Reliability
• Arc-Free With No Snubbing Circuits
• 3750VRMS Input/Output Isolation
• FCC Compatible
• VDE Compatible
• No EMI/RFI Generation
• Machine Insertable, Wave Solderable
• Current Limiting, Surface Mount and Tape & Reel
Versions Available
Approvals
• UL Recognized: File Number E76270
• CSA Certified: File Number LR 43639-10
• BSI Certified:
• BS EN 60950:1992 (BS7002:1992)
Certificate #:7344
• BS EN 41003:1993
Certificate #:7344
Ordering Information
Applications
• Telecommunications
• Telecom Switching
• Tip/Ring Circuits
• Modem Switching (Laptop, Notebook, Pocket Size)
• Hookswitch
• Dial Pulsing
• Ground Start
• Ringer Injection
• Instrumentation
• Multiplexers
• Data Acquisition
• Electronic Switching
• I/O Subsystems
• Meters (Watt-Hour, Water, Gas)
• Medical Equipment-Patient/Equipment Isolation
• Security
• Aerospace
• Industrial Controls
Part #
LCA127L
LCA127LS
LCA127LSTR
Description
6 Pin DIP (50/Tube)
6 Pin Surface Mount (50/Tube)
6 Pin Surface Mount (1000/Reel)
Pin Configuration
LCA127/L127L Pinout
LCA127/LCA127L Pinout
AC/DC Configuration
DC Only Configuration
+ Control
– Control
Do Not Use
1
6
2
5
3
4
Load
+ Control
Do Not Use
– Control
Load
Do Not Use
1
6
2
5
3
4
+ Load
– Load
Switching Characteristics of
Normally Open (Form A) Devices
10ms
CONTROL
LOAD 10%+
+90%
TON
DS-LCA127L-R2
www.clare.com
10%+
TOFF
1
LCA127L
Absolute Maximum Ratings (@ 25o C)
Parameter
Min
Input Power Dissipation
Input Control Current
Peak (10ms)
Reverse Input Voltage
Total Power Dissipation
Capacitance
Input to Output
Isolation Voltage
Input to Output
3750
Operational Temperature
-40
Storage Temperature
-40
Soldering Temperature
DIP Package
Flatpack/Surface Mount Pkg (10 Seconds Max.)
1
Derate Linearly 1.33 mw/oC
2
Derate Linearly 6.67 mw/oC
Absolute Maximum Ratings are stress ratings. Functional
operation of the device at these or any other conditions
beyond those indicated in the operational sections of this
data sheet is not implied. Exposure of the device to the
absolute maximum ratings for an extended period may
degrade the device and effect its reliability.
Typ Max Units
-
1501
50
1
5
8002
mW
mA
A
V
mW
3
-
pF
-
VRMS
°C
+85
+125 °C
+260 °C
+220 °C
Electrical Characteristics
PARAMETER
Output Characteristics @ 25°C
Load Voltage (Peak)
Load Current* (Continuous)
AC/DC Configuration
DC Configuration
Peak Load Current
On-Resistance
AC/DC Configuration
DC Configuration
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Load Current Limiting
Input Characteristics @ 25°C
Input Control Current
Input Dropout Current
Input Voltage Drop
Reverse Input Voltage
Reverse Input Current
Input to Output Capacitance
Input to Output Isolation
CONDITIONS
SYMBOL
MIN
TYP
MAX
UNITS
-
VL
-
-
250
V
10ms
IL
IL
ILPK
-
-
170
250
-
mA
mA
mA
IL=200mA
IL=200mA
VL=250V
RON
RON
ILEAK
-
13
5
-
15
6
1
Ω
Ω
µA
IF=5mA, VL=10V
IF=5mA, VL=10V
50V; f=1MHz
-
TON
TOFF
COUT
ICL
190
50
235
5
5
280
ms
ms
pF
IL= 200mA
IF= 5mA
VR=5V
-
IF
IF
VF
VR
IR
CI/O
VI/O
5
0.4
0.9
3750
0.7
1.2
3
-
50
1.4
5
10
-
mA
mA
V
V
µA
pF
VRMS
*NOTE: If both poles operate simultaneously load current must be derated so as not to exceed the package power dissipation value.
2
www.clare.com
Rev. 9
LCA127L
Performance Data
LCA127L
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 5mADC)
Device Count (N)
25
20
15
10
35
35
30
30
25
20
15
10
5
5
0
0
1.17
1.19
1.21
1.23
11.25
15
10
11.75
12.25
12.75 13.25
13.75
262.5
LCA127L
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
20
20
5
0
Device Count (N)
20
Device Count (N)
25
10
15
10
5
0.99
1.17
1.35
0.45
0.63
0.81
LED Current (mA)
5
0.99
1.17
1.35
0.33
1.53
Load Current (mA)
20
15
10
5
350
0.018
300
0.016
0.08
0.11
0.14
0.17
200
150
20mA
10mA
5mA
100
350
3.000
300
2.500
Turn-On (ms)
150
100
0
0
20
40
60
80
100
20
40
-40
120
-20
0
60
Temperature (°C)
80
100
20
40
60
80
100
Temperature (°C)
LCA127L
Typical Turn-Off vs. Temperature
(Load Current = 170mADC)
0.180
0.160
0.140
2.000
1.500
1.000
5mA
20mA 10mA
0
0
0.006
0.004
0.500
50
-20
0.01
0.008
LCA127L
Typical Turn-On vs. Temperature
(Load Current = 170mADC)
LCA127L
Typical Blocking Voltage vs. Temperature
-40
0.012
Temperature (°C)
200
1.43
0
-20
Turn-Off (ms)
250
1.21
0.002
-40
0.20
0.99
0.014
250
0
0
0.77
LCA127L
Typical Leakage vs. Temperature
(Measured across Pins 4 & 6)
50
0.05
0.55
Turn-On (ms)
LCA127L
Typical Load Current vs. Temperature
25
Blocking Voltage (VRMS)
10
LED Current (mA)
LCA127L
Typical Turn-Off Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 5mADC)
287.5
0
1.53
Leakage (µA)
0.81
282.5
15
0
0.63
277.5
LCA127L
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 5mADC)
25
15
272.5
Blocking Voltage (V)
25
0.45
267.5
On-Resistance (Ω)
LCA127L
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
Device Count (N)
20
0
1.25
LED Forward Voltage Drop (V)
Device Count (N)
25
5
-40
-20
0
20
40
60
Temperature (°C)
80
100
Turn-Off (ms)
Device Count (N)
30
LCA127L
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
Device Count (N)
35
LCA127L
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25°C)
IF = 5mADC
0.120
0.100
0.080
0.060
5mA
0.040
0.020
0
-40
-20
0
20
40
60
80
100
Temperature (°C)
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
Rev. 2
www.clare.com
3
LCA127L
Performance Data
LCA127L
Typical Turn-On vs. LED Forward Current
(Load Current = 170mADC)
1.6
1.4
50mA
30mA
20mA
10mA
5mA
1.2
1.0
0.700
0.140
0.600
0.120
0.500
0.100
0.400
0.300
0.200
0.100
-20
0
20
40
60
80
100
5
LCA127L
Typical On-Resistance vs. Temperature
(Load Current = 170mADC; IF = 5mADC)
20
25
30
35
40
45
50
0
40.000
30.000
20.000
10.000
1.500
1.000
0.500
60
80
100
Temperature (°C)
Load Current (A)
100
50
0
-50
-100
-20
0
20
40
60
80
-200
-2.5 -2.0 -1.5 -1.0 -0.5
0
0.5 1.0 1.5 2.0 2.5
Load Voltage (V)
35
40
45
50
1.000
0.500
-20
0
20
40
60
80
100
Temperature (°C)
LCA127L
Typical Current Limiting vs. Temperature
IF = 5mADC
1.2
300.00
1.0
250.00
0.8
0.6
0.4
200.00
150.00
100.00
50.00
0.2
-150
30
1.500
-40
100
LCA127L
Energy Rating Curve
150
25
2.000
Temperature (°C)
LCA127L
Typical Load Current vs. Load Voltage
(Ambient Temperature = 25°C)
IF = 5mADC
20
0
-40
Current (mA)
40
15
LCA127L
Typical IF for Switch Dropout vs. Temperature
(Load Current = 170mADC)
0
20
10
2.500
2.000
0
0
5
LED Forward Current (mA)
Operate Current (mA)
Operate Current (mA)
On-Resistance (Ω)
15
2.500
50.000
200
10
LCA127L
Typical IF for Switch Operation vs. Temperature
(Load Current = 170mADC)
60.000
-20
0.040
LED Forward Current (mA)
Temperature (°C)
-40
0.060
0
0
120
0.080
0.020
0
0.8
-40
Load Current (mA)
LCA127L
Typical Turn-Off vs. LED Forward Current
Load Current = 170mADC)
Turn-Off (ms)
1.8
Turn-On (ms)
LED Forward Voltage Drop (V)
LCA127L
Typical LED Forward Voltage Drop
vs. Temperature
0
10µs 100µs 1ms 10ms 100ms
0
1s
Time
10s 100s
-40
-20
0
20
40
60
80
100
Temperature (°C)
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
4
www.clare.com
Rev. 2
LCA127L
Mechanical Dimensions
8.382 ± .635
(.330 ± .025)
6 Pin DIP Through Hole (Standard)
2.540 ± .127
(.100 ± .005)
7.620 ± .254
(.300 ± .010)
7.239 TYP.
(.285)
3.302
(.130)
6.350 ± .127
(.250 ± .005)
9.144 ± .508
(.360 ± .020)
PC Board Pattern
(Top View)
2.540 ± .127
(.100 ± .005)
9.525 ± .254
(.375 ± .010)
6.350 ± .127
(.250 ± .005)
.254 TYP.
(.010)
7.620 ± .127
(.300 ± .005)
5.080 ± .127
(.200 ± .005)
2.540 ± .127
(.100 ± .005)
3.302
(.130)
2.540 ± .127
(.100 ± .005)
6.350 ± .127
(.250 ± .005)
9.144
(.360)
8.382 ± .635
(.330 ± .025)
7.620 ± .254
(.300 ± .010)
.635 TYP.
(.025)
6-.800 DIA.
(6-.031 DIA.)
.457 ± .076
(.018 ± .003)
6 Pin DIP Surface Mount (“S” Suffix)
4.445 ± .127
(.175 ± .005)
PC Board Pattern
(Top View)
8.305 ± .127
(.327 ± .005)
1.905 ± .127
(.075 ± .005)
.457 ± .076
(.018 ± .003)
1.499 ± .127
(.059 ± .005)
Tape and Reel Packaging for 6 Pin Surface Mount Package
330.2 DIA.
(13.00)
Top Cover
Tape Thickness
.102 MAX.
(.004)
6.731 MAX.
1.753 ± .102
(.265)
(.069 ± .004)
.406 MAX.
(.016)
2.007 ± .102 1.498 ± .102 3.987 ± .102
(.079 ± .004) (.059 ± .004) (.157 ± .004)
7.493 ± .102
(.295 ± .004)
1
6
12.090
(.476)
10.100
(.398)
4.877
(.192)
Top Cover
Tape
Embossed Carrier
Embossment
16.002 ± .305
(.630 ± .012)
.050R TYP.
11.989 ± .102
(.472 ± .004)
10.100 ± .102
(.398 ± .004)
1.549 ± .102
(.061 ± .004)
User Direction of Feed
Dimensions
mm
(inches)
Rev. 2
5
www.clare.com
Rev. 2
5
Worldwide Sales Offices
CLARE LOCATIONS
EUROPE
ASIA PACIFIC
Clare Headquarters
78 Cherry Hill Drive
Beverly, MA 01915
Tel: 1-978-524-6700
Fax: 1-978-524-4900
Toll Free: 1-800-27-CLARE
European Headquarters
CP Clare nv
Bampslaan 17
B-3500 Hasselt (Belgium)
Tel: 32-11-300868
Fax: 32-11-300890
Clare Micronix Division
145 Columbia
Aliso Viejo, CA 92656-1490
Tel: 1-949-831-4622
Fax: 1-949-831-4628
France
Clare France Sales
Lead Rep
99 route de Versailles
91160 Champlan
France
Tel: 33 1 69 79 93 50
Fax: 33 1 69 79 93 59
Asian Headquarters
Clare
Room N1016, Chia-Hsin, Bldg II,
10F, No. 96, Sec. 2
Chung Shan North Road
Taipei, Taiwan R.O.C.
Tel: 886-2-2523-6368
Fax: 886-2-2523-6369
SALES OFFICES
AMERICAS
Americas Headquarters
Clare
78 Cherry Hill Drive
Beverly, MA 01915
Tel: 1-978-524-6700
Fax: 1-978-524-4900
Toll Free: 1-800-27-CLARE
Eastern Region
Clare
P.O. Box 856
Mahwah, NJ 07430
Tel: 1-201-236-0101
Fax: 1-201-236-8685
Toll Free: 1-800-27-CLARE
Central Region
Clare Canada Ltd.
3425 Harvester Road, Suite 202
Burlington, Ontario L7N 3N1
Tel: 1-905-333-9066
Fax: 1-905-333-1824
Western Region
Clare
1852 West 11th Street, #348
Tracy, CA 95376
Tel: 1-209-832-4367
Fax: 1-209-832-4732
Toll Free: 1-800-27-CLARE
Canada
Clare Canada Ltd.
3425 Harvester Road, Suite 202
Burlington, Ontario L7N 3N1
Tel: 1-905-333-9066
Fax: 1-905-333-1824
Germany
Clare Germany Sales
ActiveComp Electronic GmbH
Mitterstrasse 12
85077 Manching
Germany
Tel: 49 8459 3214 10
Fax: 49 8459 3214 29
Italy
C.L.A.R.E.s.a.s.
Via C. Colombo 10/A
I-20066 Melzo (Milano)
Tel: 39-02-95737160
Fax: 39-02-95738829
Sweden
Clare Sales
Comptronic AB
Box 167
S-16329 Spånga
Tel: 46-862-10370
Fax: 46-862-10371
United Kingdom
Clare UK Sales
Marco Polo House
Cook Way
Bindon Road
Taunton
UK-Somerset TA2 6BG
Tel: 44-1-823 352541
Fax: 44-1-823 352797
http://www.clare.com
Clare cannot assume responsibility for use of any circuitry other
than circuitry entirely embodied in this Clare product. No circuit
patent licenses nor indemnity are expressed or implied. Clare
reserves the right to change the specification and circuitry, without notice at any time. The products described in this document
are not intended for use in medical implantation or other direct life
support applications where malfunction may result in direct physical harm, injury or death to a person.
Specification: DS-LCA127L-R2
©Copyright 2001, Clare, Inc.
All rights reserved. Printed in USA.
02/02/01
Similar pages