Online data sheet M40S-032200AR0, M40E-032220RT0 M4000 Standard MULTIPLE LIGHT BEAM SAFETY DEVICES M40S-032200AR0, M40E-032220RT0 | M4000 Standard MULTIPLE LIGHT BEAM SAFETY DEVICES A B C D E F Ordering information System part Type Part no. Sender M40S-032200AR0 1200002 M40E-032220RT0 On request Receiver Other models and accessories www.sick.com/M4000_Standard Detailed technical data Features H I J K L M N O P Q R S T Scanning range 0.5 m ... 70 m, configurable Low scanning range 0.5 m ... 20 m Great scanning range 9 m ... 70 m Number of beams 3 Beam separation 220 mm Response time 10 ms Synchronization Optical synchronisation End cap with integrated LED ✔ Safety-related parameters Type Type 4 (IEC 61496) Safety integrity level SIL3 (IEC 61508) SILCL3 (EN 62061) Category Category 4 (EN ISO 13849) Performance level PL e (EN ISO 13849) PFHD (mean probability of a dangerous failure per hour) 6.6 x 10-9 (EN ISO 13849) TM (mission time) 20 years (EN ISO 13849) Safe state in the event of a fault At least one OSSD is in the OFF state. Functions Functions Delivery status Restart interlock ✔ Internal External device monitoring (EDM) ✔ Activated Beam coding ✔ Uncoded Sender test ✔ Deactivated Configurable scanning range ✔ 0.5 m ... 20 m Configurable application diagnostic output ✔ Contamination (OWS) 2 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-08-24 18:11:25 Subject to change without notice M40S-032200AR0, M40E-032220RT0 | M4000 Standard MULTIPLE LIGHT BEAM SAFETY DEVICES Interfaces System connection Connection type Male connector M12, 8-pin Permitted cable length ≤ 15 m 1) Permitted cross-section ≥ 0.25 mm² Configuration method Configuration buttons Display elements LEDs 7-segment display Fieldbus, industrial network Integration via Flexi Soft safety controller CANopen, DeviceNet™, EtherCAT®, EtherNet/IP™, Modbus TCP, PROFIBUS DP, PROFINET 2) 1) 2) Depending on load, power supply and wire cross-section. The technical specifications must be observed. For additional information on Flexi Soft -> www.sick.com/Flexi_Soft. Electrical data Protection class III (EN 50178) Supply voltage VS 24 V DC (19.2 V DC ... 28.8 V DC) 1) Residual ripple ≤ 10 % 2) Power consumption ≤ 0.2 A: ≤ 0.6 A (depending on type) Safety outputs (OSSD) Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored 3) Switching voltage HIGH 24 V DC (VS – 2.25 V DC ... VS) Switching voltage LOW ≤ 2 V DC Switching current ≤ 500 mA Diagnostic outputs Type of output PNP semiconductor, short-circuit protected Switching voltage HIGH 24 V DC (VS – 4.2 V DC ... VS) Switching voltage LOW High resistance Switching current ≤ 100 mA 1) The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as accessories from SICK. 2) 3) Within the limits of VS. Applies to the voltage range between –30 V and +30 V. Mechanical data Housing cross-section 52 mm x 55.5 mm Housing material Aluminum alloy ALMGSI 0.5 Surface treatment Powder coated Front screen material Polycarbonate, scratch-resistant coating Ambient data Enclosure rating IP65 (EN 60529) Ambient operating temperature –30 °C ... +55 °C Storage temperature –30 °C ... +70 °C Air humidity 15 % ... 95 %, Non-condensing Vibration resistance 5 g, 10 Hz ... 55 Hz (IEC 60068-2-6) 2017-08-24 18:11:25 | Online data sheet Subject to change without notice OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 3 M40S-032200AR0, M40E-032220RT0 | M4000 Standard MULTIPLE LIGHT BEAM SAFETY DEVICES A B C D E F H I J K L M N O P Q R S T Shock resistance 10 g, 16 ms (IEC 60068-2-29) Other information Wave length 950 nm Classifications ECl@ss 5.0 27272703 ECl@ss 5.1.4 27272703 ECl@ss 6.0 27272703 ECl@ss 6.2 27272703 ECl@ss 7.0 27272703 ECl@ss 8.0 27272703 ECl@ss 8.1 27272703 ECl@ss 9.0 27272703 ETIM 5.0 EC001832 ETIM 6.0 EC001832 UNSPSC 16.0901 46171620 4 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-08-24 18:11:25 Subject to change without notice M40S-032200AR0, M40E-032220RT0 | M4000 Standard MULTIPLE LIGHT BEAM SAFETY DEVICES 25 55.5 (2.19) 27.5 52 (2.05) (0.98) Dimensional drawing (Dimensions in mm (inch)) >20 (0.79) (1.08) 1 S1 2 Optional (receiver only): Design with integrated LED Laser warning label (receiver with integrated alignment aid only) 2 L2 L1 1 Mounting ranges for the brackets Laser output opening (receiver with integrated alignment aid only) 14 (0.55) 3.5 (0.14) 1 2.2 (0.09) 10.5 (0.41) 13 Sliding nut groove for side mounting (0.51) >20 (0.79) 12.5 23.5 (0.93) (0.49) 71.2 (2.80) 14.4 (0.57) 99.8 (3.93) S1 2 1 (0.04) 6 (0.24) Cable socket M12 angled (only with AS-Interface: aligned) 2017-08-24 18:11:25 | Online data sheet Subject to change without notice AS-Interface clip M12 (aligned) 47.5 (1.87) (1.97) Ca. 83 (3.27) (connector range) 50 (1.30) Ca. 43 (1.69) (connector range) 33 (1.22) Ca. 47 (1.85) (connector range) 31 90° Cable socket M12 with cable (left) and cable plug M12 with cable (right, optional, only on receiver) OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 5 M40S-032200AR0, M40E-032220RT0 | M4000 Standard MULTIPLE LIGHT BEAM SAFETY DEVICES A B C D E F Number of beams Beam separation S1 L1 L2 2 500 (19.69) 643 (25.31) 672 (26.46) 600 (23.62) 743 (29.25) 772 (30.39) 220 (8.66) 583 (22.95) 612 (24.09) 400 (15.75) 943 (37.13) 972 (38.27) 450 (17.72) 1,043 (41.06) 1,072 (42.20) 220 (8.66) 803 (31.61) 832 (32.76) 300 (11.81) 1,043 (41.06) 1,072 (42.20) 220 (8.66) 1,023 (40.28) 1,052 (41.42) 6 1,243 (48.94) 1,272 (50.08) 7 1,462 (57.56) 1,491 (58.70) 8 1,682 (66.22) 1,711 (67.36) 3 4 5 Connection diagram M4000 Standard connected to UE10-3OS safety relay H I J K L M N O P Q R S T +24 V M4000S Standard M4000R Standard 2 +24 V +24 V 2 BN 5 Test RES 1 WH S1 BN ADO 3 GN n.c. n.c. EDM 4 YE n.c. OSSD1 5 GR 6 n.c. OSSD2 6 PK 7 GND GND 7 BU FE SH 1 3 BU 4 SH FE FE B1 B3 Y1 13 23 33 41 Y2 14 24 34 42 1) H3 UE10-3OS B2 B4 0V E119914/00/2014-07-29 2) PELV Task Connection of an M4000 Standard multiple light beam safety device to a UE10-3OS safety relay. Operating mode: with restart interlock and external device monitoring. Operating characteristics When the light path is clear and the UE10-3OS is de-energized and functioning correctly, the yellow LED on the receiver and the H3 lamp flash. The system is ready for switch-on and waits for an input signal/switch-on signal. The system is enabled by pressing and releasing the S1 button. The OSSD1 and OSSD2 outputs are live, the UE10-3OS is switched on. On interruption of one or several of the light beams, the UE10-3OS is de-energized by the OSSD1 and OSSD2 outputs. Fault analysis OSSD cross-circuits and short-circuits are detected and lead to the inhibited state (lock-out). The erroneous behavior of the UE10-3OS will be detected. The shutdown function is retained. On manipulation (e.g., jamming) of the S1 button, the system does not enable the output current circuits. Comments 1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z path) is only possible with a single-channel control and by taking the risk analysis into account. 2) PELV in accordance with the requirements in EN 60204-1 / 6.4 Take note of the operating instructions of the integrated devices. 6 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-08-24 18:11:25 Subject to change without notice M40S-032200AR0, M40E-032220RT0 | M4000 Standard MULTIPLE LIGHT BEAM SAFETY DEVICES Recommended accessories Other models and accessories www.sick.com/M4000_Standard Brief description Type Part no. BEF-3WNGBAST4 7021352 4 pieces, Mounting kit 6, side bracket, rotatable, Zinc diecast BEF-1SHABAZN4 2019506 4 pieces, Mounting kit 12, rotatable, swivel mount BEF-2SMGEAKU4 2030510 AR60 1015741 AR60 adapter, M4000 4040006 Mounting brackets and plates 4 pieces, Mounting kit 1, mounting bracket, rigid, L-shaped, including fixing screws and washers Terminal and alignment brackets Alignment aids Laser alignment aid for various sensors, laser class 2 (IEC 60825). Do not look into the beam! Adapter AR60 for M4000 and M4000 Curtain 2017-08-24 18:11:25 | Online data sheet Subject to change without notice OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 7 Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” Worldwide presence: Contacts and other locations – www.sick.com SICK AG | Waldkirch | Germany | www.sick.com