Coto FR2S1015 Proximity sensing, smoke alarm Datasheet

Dyad®
SRC
FR2
DEVICES
Features
• Small size
• SMT-compatible
• Easily formed leads
• Sputtered ruthenium contacts
• Hermetically sealed contacts
• Fast switching speed — up to 500Hz
• Wide range of available magnetic sensitivities
Description
SRC Devices DYAD® dry reed switches are ideally suited
for small switching signal applications. This switch has
sputtered ruthenium contacts and an extraordinary seal
strength, achieved by a patented laser sealing of the glass.
In low level or dry switching environments, both switches
typically provide >1 billion operations. The switches have
hermetically sealed contacts and offer a wide range of
available magnetic sensitivities.
Applications
• Security
• Proximity sensing
• Smoke alarms
• Automotive
• Level sensor
• Lamp current sensor
• Relays
Ordering Information
A complete part number is represented by the digits to the right. For example, FR2S1030 is a
DYAD® with a minimum operate value of 10 and a maximum of 30. Refer to the switch operating
specification charts for available ranges. Special ranges are available upon request.
FR2 S XX XX
Minimum Operate Value (NI)
Maximum Operate Value (NI)
Surface Mount Dyad
Refer to operating characteristics table for complete part number.
Approvals
• UL listed
DYAD®
Part #
Standard Test Coil
The magnetic force (expressed in NI, AT or Ampere Turns) required to cause the reed switch contacts to
close is called the pull-in or operate value.
FR2
Part #
Coil definition
Coil resistance
Number of turns
Wire size (nom. diameter)
Bobbin diameter (inside coil)
Winding length
Coil - 1
NARM1 CTC01
1200Ω
5,000
0.0399mm (AWG 46)
3.96mm
10.4mm
(1)
Consult factory for test procedure.
The reed switch shall be placed in the test coil with the gap centered in the core of the coil winding.
Test leads and their clips must be non-magnetic.
The longitudinal axis of the test coil and the test switch shall be vertical.
FR2S1015
FR2S1020
FR2S1030
FR2S1520
FR2S1525
FR2S2025
10 to 15
10 to 20
10 to 30
15 to 20
15 to 25
20 to 25
DYAD® Surface Mount
Part #
FR2024
FR2259
FR2282
FR2025
FR2249
FR2026
1
2
3
www.srcdevices.com
Operate Range (NI)1
Operate Range (NI)1,2,3
10 to 15
10 to 20
10 to 30
15 to 20
15 to 25
20 to 25
Tolerance = ± 1.5NI
Full Blade Sensitivity
Surface Mount Switches are packaged 3,000 parts per reel
1
SRC
Dyad®
DEVICES
FR2
Ratings (@ 25˚ C)
Parameter
Min
Switching Voltage
FR2 - DYAD®
Switching Current
FR2 - DYAD®
Carry Current
FR2 - DYAD®
Switching Frequency
FR2 - DYAD®
Contact Resistance
FR2 - DYAD®
Typ Max Units
200
Volts
0.5
Amps
1.5
Amps
500
Hz
150
mΩ
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for extended period may degrade the device and effect
its reliability.
(See detailed specifications for more information.)
Specifications
All parameters are at 25°C unless otherwise stated.
PARAMETER
Contact Ratings
Operate ampere turns range
Release ampere turns range
Switching Voltage
Switching Current
Carry Current
Contact Rating
Life Expectancy
Static Contact Resistance
Contact Material
Switch Specifications
Insulation Resistance(2)
Capacitance
Dielectric Strength(5)
Operate Time,
including bounce
Release Time
Environmental Ratings
Storage Temperature
Operating Temperature
Soldering Temperature
Vibration Resistance
Shock Resistance
Weight
CONDITIONS
SYMBOL
MIN
TYP
MAX
UNITS
Full Blade Tolerance = ± 1.5NI
Full Blade Tolerance = ± 1.5NI
Max DC/PeakAC Resistive
Max DC/PeakAC Resistive
Max DC/PeakAC Resistive
Max DC/PeakAC Resistive
1V, 10mA Signal Level
10V, 10mA Low Level
50V, 100mA Telecom Load
100V, 100mA Rated Loads
50mV, 10mA(1)
AT
AT
VL
IL
IC
CR
-
10
5
-
1000
500
2
2
80
Ru
30
30
200
500
1.5
10
150
-
NI
NI
VDC
mAmps
Amps
VA
x106 Ops
x106 Ops
x106Ops
x106 Ops
mΩ
-
100V, 25°C, 40% RH
Across Open Contacts
Between Contacts
At nominal coil voltage,
10Hz Square Wave
Zener-Diode Suppression(3)
IR
TOP
109
250
-
1011
0.3
300
-
0.5
Ω
pF
VDC/Peak AC
ms
TREL
-
-
0.2
ms
TA
TO
G
S
-
-40
-40
-
0.13
+125
+125
+240
20
100
-
°C
°C
°C
Gs
Gs
grams/unit
5Hz - 200Hz
11±1ms, 1/2 Sine Wave
(1)
Contact resistance measured with 4 terminal method, 1.1" between test leads
>1012 Ω is available upon request
A 24V zener in series with a diode across the coil
(4)
Use caution not to exceed vibration resistance limits while ultrasonically cleaning. Contact Clare Engineering for more details/recommendations
(5)
15 ampere turn minimum
(2)
(3)
USA 1-866-SRC-8668 Europe 32-89-328850
www.srcdevices.com
Far East 886-2-2698-8422
2
SRC
DEVICES
Dyad®
FR2
Performance Data*
DYAD®
CM15 Series
Operate NI vs. Release NI
Test Coil: NARM 1; Full Length Terminals
Percent Operate Increase
After Lead Cut
Release NI
20
15
10
5
0
10 12 14
1200
40
Minimum
Maximum
25
Dielectric Breakdown (VDC)
30
35
30
25
20
15
10
5
16 18 20 22 24 26 28 30
DYAD®
Capacitance Across Open Contacts
30
25
20
15
10
5
0
0.25
0.3
0.35
600
400
200
0.8
0.40
0.9
1
1.1
1.2
8-9
1.355
12-13
16-17
20-21
24-2526-32
Overall Length in Inches
Average Operate (NI)
DYAD®
Contact Resistance Throughout Life
10V, 12mA Resistive Load
DYAD®
Contact Resistance Throughout Life
50V, 100mA Resistive Load
60
Average Resistance (mOhms)
Average Resistance (mOhms)
Number of Units
35
0.2
800
0
0.7
40
Min.
Avg.
Max.
1000
0
Operate NI
0.15
DYAD®
Dielectric Breakdown vs.
Operate Sensitivity
DYAD®
Operate Shift After Lead Trimming
50
40
30
20
10
0
80
70
60
50
40
30
20
10
0
0 10 20 30 40 50 60 70 80 90 100 110 120
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0
Operations (Millions)
Operations (Millions)
Capacitance (pF)
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications,
please contact our application department.
Mechanical Dimensions
DIMENSIONS
mm
(inches)
DYAD®
DYAD® SMT
2.29 MAX.
2.29 MAX.
(0.090)
+ 7o
0.25 MAX.
(0.900)
0.18
(R 0.010)
(0.007)
15.24 MAX.
(0.600)
4 PLACES
2.03 MAX.
1.22
(0.048)
(0.080)
1.65 MAX.
(0.065)
1.20 TYP.
15.24 MAX.
(0.047)
(0.600)
1.32 MAX.
1.02
(0.052)
(0.040)
+ 10o
17.53
(0.690)
MAX. TWIST ALLOWED
9.65 REF.
TYP. BOTH ENDS
+ 5o
(0.380)
34.54 MAX.
1.32 MAX.
(1.360)
19.56 MAX.
(0.052)
(0.770)
Recommended Pad Sizes
DIMENSIONS
mm
(inches)
DYAD® SMT
2.54
(0.100)
2.79
(0.110)
16.01 MAX.
(0.63)
USA 1-866-SRC-8668 Europe 32-89-328850
www.srcdevices.com
Far East 886-2-2698-8422
3
SRC
Dyad®
DEVICES
FR2
Tape & Reel Packaging
DIMENSIONS
mm
(inches)
Tape and Reel Packaging for DYAD®-Gull Wing Terminals
2.00
.300 ± .013
(.012 ± .0005)
Top Cover
4.00
1.55 ± .05
(.079 )
1.75
(.061 ± .002)
(.157)
(.069)
Tape Thickness
.10 MAX.
(.004)
32.00 ± .31
14.20
(1.260 ± .012)
(.559)
23.01 MAX
(.906)
20.12
(.792)
Embossed Carrier
28.40
14.63
(1.118)
(.576)
2.29
(.090)
Embossment
.50
(.020)
Top Cover
Tape
8.00
2.49
(.315)
(.098)
2.00 MIN. DIA. TYP.
(.079)
User Direction of Feed
8¡ MAX
1.93
.28
(.076 )
(.011 )
2.49
(.098 )
USA 1-866-SRC-8668 Europe 32-89-328850
www.srcdevices.com
Far East 886-2-2698-8422
4
Similar pages