MORNSUN F0305S-1WR2 Dc/dc converter Datasheet

DC/DC Converter
E_S-1WR2 & F_S-1WR2 series
1W, Fixed input voltage , isolated & unregulated
dual/single output
FEATURES
 Miniature SIP package, International standard
pin-out
 Conversion efficiency high up to 81%
 Isolation voltage: 3K VDC
 Operating temperature range: -40℃ to +105℃
 EN60950,UL60950 Approval
Patent Protection RoHS
E_S-1WR2 & F_S-1WR2 series is specially designed for applications where an isolated voltage is required in a distributed power supply system.
It is suitable for:
1.Where the voltage of the input power supply is stable (voltage variation: ±10%Vin);
2.Where isolation is necessary between input and output (isolation voltage ≤3000VDC);
3.Where do not has high requirement of line regulation, load regulation and low ripple noise;
4.Such as: pure digital circuits, low frequency analog circuits and relay-driven circuits.etc.
Selection Guide
Input Voltage (VDC)
Certification
Nominal
Output Voltage
Output Current (mA)
Efficiency
(%,Min./Typ.)
(Range)
(VDC)
(Max./Min.)
@ Full Load
Max.
Capacitive
Load* (µF)
±12
±42/±5
72/76
100
3.3
303/30
69/73
5
200/20
74/78
F0324S-1WR2
24
42/5
74/78
E0505S-1WR2
±5
±100/±10
76/80
E0509S-1WR2
±9
±56/±6
76/80
E0512S-1WR2
±12
±42/±5
76/80
E0515S-1WR2
±15
±33/±4
77/81
±24
±21/±2
77/81
3.3
303/30
69/73
Part No.
E0312S-1WR2
--
UL/CE
F0303S-1WR2
F0305S-1WR2
E0524S-1WR2
--
F0503S-1WR2
F0505S-1WR2
UL/CE
--
UL/CE
3.3
(2.97-3.63)
5
(4.5-5.5)
5
200/20
76/80
F0509S-1WR2
9
111/12
76/80
F0512S-1WR2
12
83/9
76/80
F0515S-1WR2
15
67/7
77/81
-CE
100
220
F0524S-1WR2
24
42/5
77/81
±9
±56/±6
76/80
100
220
F0909S-1WR2
9
(8.1-9.9)
9
111/12
76/80
E1205S-1WR2
±5
±100/±10
76/80
E1212S-1WR2
±12
±42/±5
77/81
E1215S-1WR2
±15
±33/±4
77/81
±24
±21/±2
76/80
3.3
303/30
71/75
F1203S-1WR2
F1205S-1WR2
UL/CE
220
E0909S-1WR2
E1224S-1WR2
--
Output
12
(10.8-13.2)
5
200/20
76/80
F1209S-1WR2
9
111/12
76/80
F1212S-1WR2
12
83/9
76/80
F1215S-1WR2
15
67/7
77/81
F1224S-1WR2
24
42/5
77/81
±5
±100/±10
76/80
±15
±33/±4
77/81
5
200/20
76/80
E1505S-1WR2
E1515S-1WR2
F1505S-1WR2
15
(13.5-16.5)
2015.09.21-B/0
100
220
100
220
Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
E_S-1WR2 & F_S-1WR2 series
-CE
UL/CE
F1509S-1WR2
9
111/12
76/80
F1512S-1WR2
12
83/9
76/80
F1515S-1WR2
15
67/7
77/81
E2405S-1WR2
±5
±100/±10
76/80
E2409S-1WR2
±9
±56/±6
76/80
E2412S-1WR2
±12
±42/±5
77/81
E2415S-1WR2
±15
±33/±4
75/79
±24
±21/±2
76/80
3.3
303/30
71/75
5
200/20
75/79
F2409S-1WR2
9
111/12
76/80
F2412S-1WR2
12
83/9
77/81
F2415S-1WR2
15
67/7
77/81
F2424S-1WR2
24
42/5
77/81
E2424S-1WR2
--
F2403S-1WR2
F2405S-1WR2
UL/CE
24
(21.6-26.4)
100
220
Note:*The capacitive loads of positive and negative outputs are identical.
Input Specifications
Item
Input Current (full load / no-load)
Surge Voltage (1sec. max.)
Operating Conditions
Min.
Typ.
Max.
3.3 VDC input
--
415/25
--/70
5 VDC input
--
274/20
--/60
9 VDC input
--
139/20
--/55
12 VDC input
--
114/15
--/50
15 VDC input
--
84/10
--/35
24 VDC input
--
58/7
--/30
3.3 VDC input
-0.7
--
5
5 VDC input
-0.7
--
9
9 VDC input
-0.7
--
12
12 VDC input
-0.7
--
18
15 VDC input
-0.7
--
21
24 VDC input
-0.7
--
30
Input Filter
Unit
mA
VDC
Capacitor filter
Hot Plug
Unavailable
Output Specifications
Item
Operating Conditions
Min.
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise*
Temperature Drift Coefficient
Short Circuit Protection
Typ.
Max.
Unit
See tolerance envelope curve(Fig. 1)
Input voltage
change: ±1%
10%-100%
load
20MHz
bandwidth
3.3 VDC output
--
--
±1.5
Other output
--
--
±1.2
3.3VDC output
--
18
--
5VDC output
--
12
--
9VDC output
--
9
--
12VDC output
--
8
--
15VDC output
--
7
--
24VDC output
--
6
--
--
30
--
--
60
--
--
--
±0.03
%/℃
--
--
1
s
The output voltage is 12VDC
and under
15VDC and 24VDC output
voltage
100% load
E0524S-1WR2/F0524S-1WR2/ E24xxS-1WR2/
F24xxS-1WR2
Others
--
%
mVp-p
Continuous, self-recovery
Note: * Ripple and noise tested with “parallel cable” method, please see DC-DC Converter Application Notes for specific operation methods.
**Supply voltage must be discontinued at the end of short circuit duration for E0524S-1WR2/F0524S-1WR2/E24xxS-1WR2/F24xxS-1WR2 models.
2015.09.21-B/0
Page 2 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
E_S-1WR2 & F_S-1WR2 series
General Specifications
Item
Operating Conditions
Input-output, with the test time of 1 minute and the leak
current lower than 1mA
Min.
3000
--
--
VDC
Isolation Resistance
Input-output, isolation voltage 500VDC
1000
--
--
MΩ
Isolation Capacitance
Input-output, 100KHz/0.1V
pF
Operating Temperature
Derating if the temperature ≥85℃(see Fig. 2)
Isolation Voltage
Storage Temperature
Typ.
Max.
--
20
--
-40
--
105
-55
--
125
Casing Temperature Rise
Ta=25℃
--
25
--
Pin Welding Resistance Temperature
Welding spot is 1.5mm away from the casing, 10 seconds
--
--
300
Storage Humidity
Non-condensing
--
--
Switching Frequency
100% load, nominal input voltage
--
100
MTBF
MIL-HDFK-217F@25℃
3500
--
95
--
Unit
℃
℃
%
KHz
--
K hours
Physical Specifications
Casing Material
Black flame-retardant heat-proof epoxy resin (UL94-V0)
Package Dimensions
19.50*6.00*9.30 mm
Weight
2.40g(Typ.)
Cooling Method
Free air convection
EMC Specifications
EMI
EMS
Conducted disturbance
CISPR22/EN55022 CLASS B (see Fig. 4 for recommended circuit)
Radiated emission
Electrostatic discharge
CISPR22/EN55022 CLASS B (see Fig. 4 for recommended circuit)
E_S-1WR2
IEC/EN61000-4-2
Contact ±6KV
perf. Criteria B
F_S-1WR2
IEC/EN61000-4-2
Contact ±8KV
perf. Criteria B
Product Characteristic Curve
Others output
Tolerance Envelope Cur ve
Output Voltage Accuracy
+15%
Max .
+5%
+1.0%
0
Ty p .
-5%
-7.5%
M in.
-10%
-15%
-15%
10% 20%
40%
60%
80%
Tolerance Envelope Cur ve
+10%
Max .
+5%
Ty p .
0
+2.5%
M in.
-5%
-2.5%
-7.5%
-10%
10% 20%
100%
40%
60%
80%
100%
Output Current Percent
(Nominal Input Voltage)
Output Current Percentage
(Nominal Input Voltage)
Fig. 1
Output Power Percentage(%)
Output Voltage Accuracy
3.3VDC output
+10%
Temperature Derating Graph
120
100
80
60
40
Safe Operating Area
20
0
-40
40
85 105
0
Ambient Temperature(℃ )
Fig. 2
2015.09.21-B/0
Page 3 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
E_S-1WR2 & F_S-1WR2 series
Design Reference
1. Typical application
If it is required to further reduce input and output ripple, a filter capacitor can be connected to the input and output terminals, see Fig.3.
Moreover, choosing suitable filter capacitor is very important , start-up problems may be caused by too large capacitance. To ensured the
modules running well, the recommended capacitive load values as shown in Table 1.
Dual Output
Vin
Cout
DC DC
Cin
GND
Cout
+Vo
0V
+Vo
DC DC
Cin
GND
Vin
(VDC)
Cin
(µF)
Slngle
output
Cout
(µF)
Dual
output
3.3/5
4.7
3.3/5/9
10
±3.3/±5
9/12
4.7
2.2
12
2.2
±9/±12
1
15
2.2
15/24
1
±15/±24
0.47
24
1
--
--
--
--
(VDC)
-Vo
Single Output
Vin
Recommended capacitive load value table (Table 1)
Cout
0V
Cout
(µF)
(VDC)
Fig.3
2. EMC typical recommended circuit (CLASS B)
LDM
Vin
Vin
C1
GND
DC/DC
GND
Fig. 4
Input voltage(VDC)
+Vo
-Vo
(0V)
C2
LOAD
EMI
3.3/5/9/12/15/24
C1
4.7µF /50V
C2
Refer to the Cout in Fig.3
LDM
6.8µH
Note: It is not needed to add the component in the peripheral circuit when
parameter with the symbol of "--"
3. Output load requirements
In order to ensure the converter can work reliably with high efficiency, the minimum load should not less than 10% rated load when it is
used. If the needed power is indeed small, please parallel a resistor on t the output side ( The sum of the efficient power and resistor
consumption power is not less than 10%).
4. For more information please find the application notes on www.mornsun-power.com
2015.09.21-B/0
Page 4 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
E_S-1WR2 & F_S-1WR2 series
Dimensions and Recommended Layout
Notes:
1.
Packing Information please refer to 'Product Packing Information'. Packing bag number: 58200029;
2.
If the product is operated under the min. required load, the product performance cannot be guaranteed to comply with all
performance indexes in this datasheet;
3.
The max. capacitive load should be tested within the input voltage range and under full load conditions;
4.
Unless otherwise specified, data in this data sheet should be tested under the conditions of Ta=25°C, humidity<75% when inputting
nominal voltage and outputting rated load;
5.
All index testing methods in this datasheet are based on our Company’s corporate standards;
6.
The performance indexes of the product models listed in this manual are as above, but some indexes of non-standard model products
will exceed the above-mentioned requirements, and please directly contact our technicians for specific information;
7.
We can provide product customization service;
8.
Specifications of this product are subject to changes without prior notice.
MORNSUN Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: [email protected]
2015.09.21-B/0
Page 5 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Similar pages