MEDICAL & MILITARY MI COMPAC Series 5 0 - 3 0 0 W AT T S M I L I TA R Y R E A D Y T O U S E C O M P O N E N T Features • • • • • • • Inputs 28Vdc and 270Vdc Outputs 1 to 3, 1 to 95Vdc EMI Compliance: MIL-STD-461C&D/E Transients & Spikes: MIL-STD-704A, 1275A/B Quality System MIL-1-45208 Reverse polarity protected Low noise FM control Specifications ENVIRONMENTAL INPUT Storage temperature Nominal input 28Vdc 270Vdc Input range 18 – 50Vdc 125V – 400Vdc Input spike limit MIL-STD-704A MIL-STD-1275A/B -600V to +600Vdc -250V to +250Vdc 800Vdc max -600V to +600Vdc Input surge limit 100Vdc 500Vdc Overvoltage shutdown 50Vdc 400Vdc Inrush current 110% 110% of input typical Reverse polarity protection Recommended Fuse 10A 2A FO3A type Operating temperature case Shutdown temperature 270Vdc Output power 250W 250W Clamp voltage 60Vdc 420Vdc Overload protection 20A 4A Set point accuracy 0.5% V nom typical Load/Line regulation 0.2-0.5% V nom typical Output temperature drift 0.01%/°C Output noise 1%pp V nom Output voltage trimming 50%-110% Remote sense compensation Current Limit INPUT POWER LEADS Conduct emissions CE01, CE03, CE07, CE101, CE102 MIL-STD-461C & D (1 Up) CE101 MIL-STD-461E (2 Up & 3Up) Conducted susceptibility CS01, CS02, CS06, CS101, CS114, CS116 MIL-STD-461C & D (1 Up) CS101, CS114, CS116 MIL-STD-461E (2 Up & 3Up) Output to case 50–100W 200W 300W 100–200W 250–300W MI-RC [a] [b] [b] [b] – [c] [d] [d] [d] 150–300W A=INPUT VOLTAGE 105% – 125% 18-50V Z = 2Vdc 2 = 15Vdc 6=270Vdc 125-475V(1) Y = 3.3Vdc 3 = 24Vdc 28Vdc input: 2,121Vrms 270Vdc input: 2,500Vrms 500Vrms O = 5Vdc L = 28Vdc M = 10Vdc 4 = 48Vdc C=PRODUCT GRADE I = -40°C to +85°C M = -55°C to +85°C 1 = 12Vdc D=OUTPUT POWER/CURRENT 4,242Vrms B=OUTPUT VOLTAGE 2=28Vdc 219x64x25mm 219x125x25mm 219x186x25mm Isolation characteristics Input to case Dual output MI-LC [a] [b] – [c] [d] MI-MC [a] [b] – [c] [e] MI-NC [a] [b] – [c] [f] MI-PC [a] [b] [b] – [c] [d] [d] MI-QC [a] [b] [b] – [c] [e] [d] NOMINAL RANGE OPERATING Input – output Selection Table Single output # For conduction cooled models add – cc at end of model number Please substitute selection character (e.g. [a]) with value designator in the appropriate table below. 0.5V MI-LC MI-MC, MI-PC MI-NC, MI-QC, MIRC +95°C typical EMI/RFI characteristics (MIL-STD-461C, D &E) Triple output MECHANICAL Dimensions +85°C STANDARDS AND APPROVALS OUTPUT 28Vdc +100°C E=OUTPUT POW./CUR. 5V <5V 肁5V F=OUTPUT POW./CUR. <5V 肁5V <5V Y = 50W 10A U = 200W – S = 300W – X = 75W 15A S= – 60A P= – 90A W= 100W 20A V= – 30A (1) These units rated at 75% load from 125-150Vin: 5Vout @ 100W; 2Vout and 3.3Vout @ 30A. 382 5 0 - 3 0 0 W AT T S M I L I TA R Y R E A D Y T O U S E C O M P O N E N T Technical Illustrations Your dependable power partner – www.powerbox.com.au MEDICAL & MILITARY MI COMPAC Series 383