CT303X, CT304X, CT306X, CT308X 6Pin Zero Cross TRIAC Driver Coupler CT Micro Features Description High isolation 5000 VRMS The CT303X, CT304X, CT306X and CT308X series Peak Breakdown Voltage consists of a Zero Cross Photo Triac optically 250V – CT303X coupled to a gallium arsenide Infrared-emitting 400V – CT304X diode in a 6-lead DIP package with bending options. 600V – CT306X 800V – CT308X Temperature range - 55 °C to 100 °C Applications Motor Controls Lamp ballasts Static AC Power Switch Solenoid/ Valve Control Package Outline Schematic Note: Different bending options available. See package dimension. CT Micro Proprietary & Confidential Page 1 Rev 1 Aug, 2013 CT303X, CT304X, CT306X, CT308X 6Pin Zero Cross TRIAC Driver Coupler CT Micro Absolute Maximum Rating at 25oC Symbol Parameters Ratings Units 5000 VRMS VISO Isolation voltage TOPR Operating temperature -55 ~ +100 oC TSTG Storage temperature -55 ~ +125 oC TSOL Soldering temperature 260 oC Forward current 60 mA 1 A 6 V Notes Emitter IF IF(TRANS) Peak transient current (≤1μs P.W,300pps) VR Reverse voltage PD Power dissipation 100 mW Power dissipation 300 mW CT303X 250 V CT304X 400 V CT306X 600 V CT308X 800 V 1 A Detector PD VDRM ITSM Off-State Output Terminal Voltage Peak Repetitive Surge Current CT Micro Proprietary & Confidential Page 2 Rev 1 Aug, 2013 CT303X, CT304X, CT306X, CT308X 6Pin Zero Cross TRIAC Driver Coupler CT Micro Electrical Characteristics T A = 25°C (unless otherwise specified) Emitter Characteristics Symbol Parameters Test Conditions Min Typ Max Units 1.2 1.4 V VF Forward voltage IF=10mA IR Reverse Current VR = 6V - - 5 µA Input Capacitance f= 1MHz - 45 - pF Min Typ Max Units - - 100 CIN Notes Detector Characteristics Symbol Parameters Test Conditions Notes CT303X, Peak Blocking CT304X Current CT306X, IDRM1 IF= 0mA, VDRM= Rated VDRM nA - - 500 CT308X IF= Rated IFT, VDRM= Rated IDRM2 Inhibit Leakage Current 500 µA V VDRM VTM Peak On-State Voltage Critical Rate of Rise CT303X, off-State Voltage CT304X, dv/dt IF= Rated IFT, ITM= 100mA VPEAK= Rated VDRM - - 3 1000 - V/µs CT306X CT308X VPEAK = 400V 600 - - Min Typ Max - - 15 - - 10 - - 5 - 270 - Transfer Characteristics Symbol Parameters Test Conditions Units Notes CT3031, CT3041, Ct3061, CT3081 Input CT3032, CT3042, IFT Trigger Terminal Voltage = 3V V CT3062, CT3082 Current CT3033, CT3043, CT3063, CT3083 IH Holding Current RIO Isolation Resistance VIO= 500VDC CIO Isolation Capacitance f= 1Mhz CT Micro Proprietary & Confidential Ω 1x1011 0.25 Page 3 µA pF Rev 1 Aug, 2013 CT303X, CT304X, CT306X, CT308X 6Pin Zero Cross TRIAC Driver Coupler CT Micro Typical Characteristic Curves CT Micro Proprietary & Confidential Page 4 Rev 1 Aug, 2013 CT303X, CT304X, CT306X, CT308X 6Pin Zero Cross TRIAC Driver Coupler CT Micro CT Micro Proprietary & Confidential Page 5 Rev 1 Aug, 2013 CT303X, CT304X, CT306X, CT308X 6Pin Zero Cross TRIAC Driver Coupler CT Micro Package Dimension Dimensions in mm unless otherwise stated Standard DIP – Through Hole Wide Lead Forming – Through Hole CT Micro Proprietary & Confidential Page 6 Rev 1 Aug, 2013 CT303X, CT304X, CT306X, CT308X 6Pin Zero Cross TRIAC Driver Coupler CT Micro Surface Mount Forming Surface Mount Forming (Low Profile) CT Micro Proprietary & Confidential Page 7 Rev 1 Aug, 2013 CT303X, CT304X, CT306X, CT308X 6Pin Zero Cross TRIAC Driver Coupler CT Micro Recommended Solder Mask Dimensions in mm unless otherwise stated Marking Information CT 3031 YWWD Note: CT 3031 Y WW D : Logo : Part Number : Fiscal Year : Work Week : Manufacturing Code CT Micro Proprietary & Confidential Page 8 Rev 1 Aug, 2013 CT303X, CT304X, CT306X, CT308X 6Pin Zero Cross TRIAC Driver Coupler CT Micro Ordering Information CT303X(Y)(Z)-G, CT304X(Y)(Z)-G, CT306X(Y)(Z)-G, CT308X(Y)(Z)-G X = (1,2,3) Y = Lead form option (S, SL, M or none) Z = Tape and reel option (TA, TB or none) G= Material option (G: Green, None: Non-green) Option Description Quantity None Standard 6 Pin Dip 50Units/Tube M Wide Lead Forming 50Units/Tube S(TA) Surface Mount Lead Forming – With Option A Taping 1000 Units/Reel S(TB) Surface Mount Lead Forming – With Option B Taping 1000 Units/Reel SL(TA) Surface Mount Lead Forming(Low Profile) – With Option A Taping 1000 Units/Reel SL(TB) Surface Mount Lead Forming(Low Profile) – With Option B Taping 1000 Units/Reel CT Micro Proprietary & Confidential Page 9 Rev 1 Aug, 2013 CT303X, CT304X, CT306X, CT308X 6Pin Zero Cross TRIAC Driver Coupler CT Micro Reflow Profile Profile Feature Pb-Free Assembly Profile Temperature Min. (Tsmin) 150°C Temperature Max. (Tsmax) 200°C Time (ts) from (Tsmin to Tsmax) 60-120 seconds Ramp-up Rate (tL to tP) 3°C/second max. Liquidous Temperature (TL) 217°C Time (tL) Maintained Above (TL) 60 – 150 seconds Peak Body Package Temperature 260°C +0°C / -5°C Time (tP) within 5°C of 260°C 30 seconds Ramp-down Rate (TP to TL) 6°C/second max Time 25°C to Peak Temperature 8 minutes max. CT Micro Proprietary & Confidential Page 10 Rev 1 Aug, 2013 CT303X, CT304X, CT306X, CT308X 6Pin Zero Cross TRIAC Driver Coupler CT Micro DISCLAIMER CT MICRO RESERVES THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. CT MICRO DOES NOT ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN; NEITHER DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE RIGHTS OF OTHERS. ______________________________________________________________________________________ DISCOLORATION MIGHT OCCUR ON THE PACKAGE SURFACE AFTER SOLDERING, REFLOW OR LONG TERM USE. THIS DOES NOT IMPACT THE PRODUCT PERFORMANCE NOR THE PRODUCT RELIABILITY. CT MICRO ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT EXPRESS WRITTEN APPROVAL OF CT MICRO INTERNATIONAL CORPORATION. 1. Life support devices or systems are devices or 2. A critical component is any component of a life systems which, (a) are intended for surgical support device or system whose failure to perform implant into the body, or (b) support or sustain life, can be reasonably expected to cause the failure of or (c) whose failure to perform when properly used the life support device or system, or to affect its in accordance with instruction for use provided in safety or effectiveness. the labelling, can be reasonably expected to result in significant injury to the user. CT Micro Proprietary & Confidential Page 11 Rev 1 Aug, 2013