19-4811; Rev 5; 6/12 KIT ATION EVALU E L B A IL AVA Compact, Low-Cost 1S/2S Fuel Gauges with Low-Battery Alert Features o Host-Side or Battery-Side Fuel Gauging 1 Cell (MAX17043) 2 Cell (MAX17044) o Precision Voltage Measurement ±12.5mV Accuracy to 5.00V (MAX17043) ±30mV Accuracy to 10.00V (MAX17044) o Accurate Relative Capacity (RSOC) Calculated from ModelGauge Algorithm o No Offset Accumulation on Measurement o No Full-to-Empty Battery Relearning Necessary o No Sense Resistor Required o External Alarm/Interrupt for Low-Battery Warning o 2-Wire Interface o Low Power Consumption o Tiny, Lead(Pb)-Free, 8-Pin, 2mm x 3mm TDFN Package or Tiny 0.4mm Pitch 9-Bump UCSP Package The MAX17043/MAX17044 are ultra-compact, low-cost, host-side fuel-gauge systems for lithium-ion (Li+) batteries in handheld and portable equipment. The MAX17043 is configured to operate with a single lithium cell and the MAX17044 is configured for a dual-cell 2S pack. The MAX17043/MAX17044 use a sophisticated Li+ battery-modeling scheme, called ModelGauge™ to track the battery’s relative state-of-charge (SOC) continuously over a widely varying charge/discharge profile. Unlike traditional fuel gauges, the ModelGauge algorithm eliminates the need for battery relearn cycles and an external current-sense resistor. Temperature compensation is possible in the application with minimal interaction between a µC and the device. A quick-start mode provides a good initial estimate of the battery’s SOC. This feature allows the IC to be located on system side, reducing cost and supply chain constraints on the battery. Measurement and estimated capacity data sets are accessed through an I2C interface. The MAX17043/MAX17044 are available in either a 0.4mm pitch 9-bump UCSP™ or 2mm x 3mm, 8-pin TDFN lead-free package. Ordering Information PART MAX17043G+U Applications Smartphones Portable DVD Players MP3 Players GPS Systems Digital Still Cameras Handheld and Portable Applications Digital Video Cameras TEMP RANGE PIN-PACKAGE -20°C to +70°C 8 TDFN-EP* MAX17043G+T -20°C to +70°C 8 TDFN-EP* MAX17043X+ -20°C to +70°C 9 UCSP MAX17043X+T10 -20°C to +70°C 9 UCSP MAX17044G+U -20°C to +70°C 8 TDFN-EP* MAX17044G+T -20°C to +70°C 8 TDFN-EP* MAX17044X+ -20°C to +70°C 9 UCSP MAX17044X+T10 -20°C to +70°C 9 UCSP +Denotes a lead(Pb)-free/RoHS-compliant package. T = Tape and reel. *EP = Exposed pad. ModelGauge is a trademark of Maxim Integrated Products, Inc. UCSP is a trademark of Maxim Integrated Products, Inc. Simplified Operating Circuit 150Ω 1kΩ 4.7kΩ VDD SYSTEM µP ALRT INTERRUPT CELL MAX17043 MAX17044 Li+ PROTECTION CIRCUIT 1µF QSTRT CTG GND SDA EP I2C BUS MASTER SCL 10nF For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com. 1 MAX17043/MAX17044 General Description MAX17043/MAX17044 Compact, Low-Cost 1S/2S Fuel Gauges with Low-Battery Alert ABSOLUTE MAXIMUM RATINGS Voltage on CTG Pin Relative to VGND ....................-0.3V to +12V Voltage on CELL Pin Relative to VGND ...................-0.3V to +12V Voltage on All Other Pins Relative to VGND ..............-0.3V to +6V Operating Temperature Range ...........................-40°C to +85°C Storage Temperature Range (TA = 0°C to +70°C (Note 10))........................-55°C to +125°C Lead Temperature (TDFN soldering only, 10s) ...............+300°C Soldering Temperature (reflow) .......................................+260°C Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. ELECTRICAL CHARACTERISTICS RECOMMENDED DC OPERATING CONDITIONS (2.5V ≤ VDD ≤ 4.5V, TA = -20°C to +70°C, unless otherwise noted.) PARAMETER Supply Voltage Data I/O Pins SYMBOL VDD CONDITIONS MIN TYP MAX UNITS (Note 1) +2.5 +4.5 V SCL, SDA, QSTRT, (Note 1) ALRT -0.3 +5.5 V MAX17043 CELL Pin VCELL (Note 1) -0.3 +5.0 V MAX17044 CELL Pin VCELL (Note 1) -0.3 +10.0 V MAX UNITS µA DC ELECTRICAL CHARACTERISTICS (2.5V ≤ VDD ≤ 4.5V, TA = -20°C to +70°C, unless otherwise noted. Contact Maxim for VDD greater than 4.5V.) PARAMETER Active Current Sleep-Mode Current (Note 2) Time-Base Accuracy SYMBOL CELL Pin Input Impedance MIN IACTIVE I SLEEP t ERR VDD = 2.0V VGERR TYP 50 75 0.5 1.0 1 3 VDD = 3.6V at +25°C -1 +1 TA = 0°C to +70°C (Note 10) -2 +2 TA = -20°C to +70°C -3 +3 -12.5 +12.5 -30 +30 -30 +30 -60 +60 TA = +25°C, VIN = VDD MAX17043 VoltageMeasurement Error MAX17044 VoltageMeasurement Error CONDITIONS TA = +25°C, 5.0V < VIN < 9.0V 5.0 < VIN < 9.0 RCELL µA % mV mV 15 M 1.4 V Input Logic-High: SCL, SDA, QSTRT VIH (Note 1) Input Logic-Low: SCL, SDA, QSTRT VIL (Note 1) 0.5 V V Output Logic-Low: SDA VOL I OL = 4mA (Note 1) 0.4 Output Logic-Low: ALRT VOL-ALRT I OL-ALRT = 2mA (Note 1) 0.4 I PD VDD = 4.5V, VPIN = 0.4V Pulldown Current: SCL, SDA Input Capacitance: SCL, SDA CBUS Bus Low Timeout t SLEEP (Note 3) Mode Transition tTRAN (Note 4) 2 0.2 50 1.75 V µA pF 2.5 s 1 ms Compact, Low-Cost 1S/2S Fuel Gauges with Low-Battery Alert MAX17043/MAX17044 ELECTRICAL CHARACTERISTICS: 2-WIRE INTERFACE (2.5V ≤ VDD ≤ 4.5V, TA = -20°C to +70°C.) PARAMETER SYMBOL SCL Clock Frequency f SCL Bus Free Time Between a STOP and START Condition tBUF Hold Time (Repeated) START Condition tHD:STA CONDITIONS (Note 5) (Note 5) MIN 0 TYP MAX UNITS 400 kHz 1.3 µs 0.6 µs Low Period of SCL Clock tLOW 1.3 µs High Period of SCL Clock tHIGH 0.6 µs Setup Time for a Repeated START Condition t SU:STA 0.6 µs Data Hold Time tHD:DAT (Notes 6, 7) Data Setup Time t SU:DAT (Note 6) 0 0.9 100 µs ns Rise Time of Both SDA and SCL Signals tR 20 + 0.1CB 300 ns Fall Time of Both SDA and SCL Signals tF 20 + 0.1CB 300 ns t SU:STO 0.6 Setup Time for STOP Condition Spike Pulse Widths Suppressed by Input Filter t SP (Note 8) Capacitive Load for Each Bus Line CB (Note 9) SCL, SDA Input Capacitance CBIN 0 µs 50 ns 400 pF 60 pF All voltages are referenced to GND. SDA, SCL = GND; QSTRT, ALRT idle. The MAX17043/MAX17044 enter Sleep mode 1.75s to 2.5s after (SCL < VIL) AND (SDA < VIL). Time to enter sleep after Sleep command is sent. Time to exit sleep on rising edge of SCL or SDA. fSCL must meet the minimum clock low time plus the rise/fall times. The maximum tHD:DAT has only to be met if the device does not stretch the low period (tLOW) of the SCL signal. This device internally provides a hold time of at least 75ns for the SDA signal (referred to the VIHMIN of the SCL signal) to bridge the undefined region of the falling edge of SCL. Note 8: Filters on SDA and SCL suppress noise spikes at the input buffers and delay the sampling instant. Note 9: CB—total capacitance of one bus line in pF. Note 10: Applies to 8-pin TDFN-EP package type only. Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Note 7: 3 Typical Operating Characteristics (TA = +25°C, unless otherwise noted.) SIMPLE C/2 RATE CYCLES* SOC ACCURACY TA = +70°C 90 80 STATE OF CHARGE (%) TA = +25°C 60 40 20 TA = -20°C 4 60 2 50 0 40 -2 30 -4 -6 REFERENCE SOC: SOLID LINE 0 2 3 4 5 0 6 8 10 12 MAX17043 VOLTAGE ADC ERROR vs. TEMPERATURE 20 8 15 6 70 4 60 2 50 0 40 -2 30 -4 20 VOLTAGE ADC ERROR (mV) 80 10 SOC ERROR (%) 90 REFERENCE SOC: SOLID LINE 6 VCELL = 3.0V 5 0 -5 VCELL = 3.6V -10 -15 -8 -10 4 VCELL = 4.2V 10 -6 ERROR (%) 0 -20 -40 8 10 12 14 16 18 20 22 -15 TIME (hr) 10 35 TEMPERATURE (°C) C/2 RATE ZIGZAG PATTERN* SOC ACCURACY MAX17043/4 toc05 MAX17043/MAX17044 SOC: DASHED LINE 90 STATE OF CHARGE (%) 80 10 8 6 ERROR (%) 70 4 60 2 50 0 40 -2 30 -4 -6 20 REFERENCE SOC: SOLID LINE 10 -8 -10 0 0 4 8 12 16 TIME (hr) *Sample accuracy with custom configuration data programmed into the IC. 20 22 SOC ERROR (%) 100 4 -10 4 SIMPLE C/4 RATE CYCLES* SOC ACCURACY MAX17043/4 toc03 2 -8 TIME (h) MAX17043/ MAX17044 SOC: DASHED LINE 0 2 ERROR (%) VDD (V) 100 10 6 70 10 1 8 20 0 0 10 MAX17043/ MAX17044 SOC: DASHED LINE MAX17043/4 toc04 80 MAX17043/4 toc02 100 MAX17043/4 toc01 QUIESCENT CURRENT (µA) 100 60 85 SOC ERROR (%) QUIESCENT CURRENT vs. SUPPLY VOLTAGE STATE OF CHARGE (%) MAX17043/MAX17044 Compact, Low-Cost 1S/2S Fuel Gauges with Low-Battery Alert Compact, Low-Cost 1S/2S Fuel Gauges with Low-Battery Alert TOP VIEW SDA SCL QSTRT ALRT 8 7 6 5 TOP VIEW (BUMPS ON BOTTOM) MAX17043 MAX17044 1 2 3 A SDA SCL CTG B QSTRT N.C. CELL C ALRT VDD GND + MAX17043 MAX17044 + 1 2 3 4 CTG CELL VDD GND TDFN (2mm × 3mm) UCSP Pin Description PIN NAME FUNCTION UCSP TDFN A1 8 SDA Serial Data Input/Output. Open-drain 2-wire data line. Connect this pin to the DATA signal of the 2wire interface. This pin has a 0.2µA typical pulldown to sense disconnection. A2 7 SCL Serial Clock Input. Input only 2-wire clock line. Connect this pin to the CLOCK signal of the 2-wire interface. This pin has a 0.2µA typical pulldown to sense disconnection. A3 1 CTG Connect to Ground. Connect to VSS during normal operation. B1 6 QSTRT N.C. No connect. Do not connect. B3 2 CELL Battery Voltage Input. The voltage of the cell pack is measured through this pin. C1 5 ALRT Alert Output. Active-low interrupt signaling low state of charge. Connect to interrupt input of the system microprocessor. C2 3 VDD Power-Supply Input. 2.5V to 4.5V input range. Connect to system power through a decoupling network. Connect a 10nF typical decoupling capacitor close to pin. C3 4 GND — — EP B2 Quick-Start Input. Allows reset of the device through hardware. Connect to GND if not used. Ground. Connect to the negative power rail of the system. Exposed Pad (TDFN only). Connect to ground. 5 MAX17043/MAX17044 Pin Configurations MAX17043/MAX17044 Compact, Low-Cost 1S/2S Fuel Gauges with Low-Battery Alert SDA tF tLOW tSU:DAT tR tSP tF tR tBUF tHD:STA SCL tHD:STA tSU:STA tHD:DAT S tSU:STO Sr P S Figure 1. 2-Wire Bus Timing Diagram Detailed Description Figure 1 shows the 2-wire bus timing diagram, and Figure 2 is the MAX17043/MAX17044 block diagram. ModelGauge Theory of Operation The MAX17043/MAX17044 use a sophisticated battery model that determines the SOC of a nonlinear Li+ battery. The model effectively simulates the internal dynamics of a Li+ battery and determines the SOC. The model considers the time effects of a battery caused by the chemical reactions and impedance in the battery. The MAX17043/MAX17044 SOC calculation does not accumulate error with time. This is advantageous VDD MAX17043 MAX17044 BIAS TIME BASE (32kHz) VOLTAGE REFERENCE ADC (VCELL) CELL GND IC GROUND Figure 2. Block Diagram 6 STATE MACHINE (SOC, RATE) CTG 2-WIRE INTERFACE SDA QSTRT ALRT SCL compared to traditional coulomb counters, which suffer from SOC drift caused by current-sense offset and cell self-discharge. This model provides good performance for many Li+ chemistry variants across temperature and age. To achieve optimum performance, the MAX17043/MAX17044 must be programmed with configuration data custom to the application. Contact the factory for details. Fuel-Gauge Performance The classical coulomb-counter-based fuel gauges suffer from accuracy drift due to the accumulation of the offset error in the current-sense measurement. Although the error is often very small, the error increases over time in such systems, cannot be eliminated, and requires periodic corrections. The corrections are usually performed on a predefined SOC level near full or empty. Some other systems use the relaxed battery voltage to perform corrections. These systems determine the true SOC based on the battery voltage after a long time of no activity. Both have the same limitation: if the correction condition is not observed over time in the actual application, the error in the system is boundless. In some systems, a full-charge/discharge cycle is required to eliminate the drift error. To determine the true accuracy of a fuel gauge, as experienced by end users, the battery should be exercised in a dynamic manner. The end-user accuracy cannot be understood with only simple cycles. MAX17043/MAX17044 do not suffer from the drift problem since they do not rely on the current information. Compact, Low-Cost 1S/2S Fuel Gauges with Low-Battery Alert When the battery is first inserted into the system, there is no previous knowledge about the battery’s SOC. The IC assumes that the battery has been in a relaxed state for the previous 30min. The first A/D voltage measurement is translated into a best “first guess” for the SOC. Initial error caused by the battery not being in a relaxed state fades over time, regardless of cell loading following this initial conversion. Because the SOC determination is convergent rather than divergent (as in a coulomb counter), this initial error does not have a longlasting impact. Quick-Start A quick-start allows the MAX17043/MAX17044 to restart fuel-gauge calculations in the same manner as initial power-up of the IC. For example, if an application’s power-up sequence is exceedingly noisy such that excess error is introduced into the IC’s “first guess” of SOC, the host can issue a quick-start to reduce the error. A quick-start is initiated by a rising edge on the QSTRT pin, or through software by writing 4000h to the MODE register. ALERT Interrupt The MAX17043/MAX17044 have an interrupt feature that alerts a host microprocessor whenever the cell's state of charge, as defined by the SOC register, falls below a predefined alert threshold set at address 0Dh of the CONFIG register. When an alert is triggered, the IC drives the ALRT pin to logic-low and sets the ALRT bit in the CONFIG register to logic 1. The ALRT pin remains logic-low until the host software writes the ALRT bit to logic 0 to clear the interrupt. Clearing the ALRT bit while SOC is below the alert threshold does not generate another interrupt. The SOC register must first rise above and then fall below the alert threshold value before another interrupt is generated. Note that the alert function is not disabled at IC powerup. If the first SOC calculation is below the threshold setting, an interrupt is generated. Entering Sleep mode does not clear the interrupt. Sleep Mode Holding both SDA and SCL logic-low forces the MAX17043/MAX17044 into Sleep mode. While in Sleep mode, all IC operations are halted and power drain of the IC is greatly reduced. After exiting Sleep mode, fuel-gauge operation continues from the point it was halted. SDA and SCL must be held low for at least 2.5s to guarantee transition into Sleep mode. Afterwards, a rising edge on either SDA or SCL immediately transitions the IC out of Sleep mode. Alternatively, Sleep mode can be entered by setting the SLEEP bit in the CONFIG register to logic 1 through I2C communication. If the SLEEP bit is set to logic 1, the only way to exit Sleep mode is to write SLEEP to logic 0 or power-on reset the IC. Power-On Reset (POR) Writing a value of 5400h to the COMMAND register causes the MAX17043/MAX17044 to completely reset as if power had been removed. The reset occurs when the last bit has been clocked in. The IC does not respond with an I2C ACK after this command sequence. Registers All host interaction with the MAX17043/MAX17044 is handled by writing to and reading from register locations. The MAX17043/MAX17044 have six 16-bit registers: SOC, VCELL, MODE, VERSION, CONFIG, and COMMAND. Register reads and writes are only valid if all 16 bits are transferred. Any write command that is terminated early is ignored. The function of each register is described as follows. All remaining address locations not listed in Table 1 are reserved. Data read from reserved locations is undefined. Table 1. Register Summary ADDRESS (HEX) REGISTER 02h–03h VCELL 04h–05h SOC 06h–07h MODE 08h–09h DESCRIPTION READ/ WRITE DEFAULT (HEX) Reports 12-bit A/D measurement of battery voltage. R — Reports 16-bit SOC result calculated by ModelGauge algorithm. R — Sends special commands to the IC. W — VERSION Returns IC version. R — 0Ch–0Dh CONFIG Battery compensation. Adjusts IC performance based on application conditions. R/W 971Ch FEh–FFh COMMAND W — Sends special commands to the IC. 7 MAX17043/MAX17044 IC Power-Up MAX17043/MAX17044 Compact, Low-Cost 1S/2S Fuel Gauges with Low-Battery Alert VCELL Register Battery voltage is measured at the CELL pin input with respect to GND over a 0 to 5.00V range for the MAX17043 and 0 to 10.00V for the MAX17044 with resolutions of 1.25mV and 2.50mV, respectively. The A/D calculates the average cell voltage for a period of 125ms after IC POR and then for a period of 500ms for every cycle afterwards. The VCELL register requires 500ms to update after exiting Sleep mode. The result is placed in the VCELL register at the end of each conversion period. Figure 3 shows the VCELL register format. SOC Register The SOC register is a read-only register that displays the state of charge of the cell as calculated by the ModelGauge algorithm. The result is displayed as a percentage of the cell’s full capacity. This register automatically adapts to variation in battery size since the MAX17043/MAX17044 naturally recognize relative SOC. Units of % can be directly determined by observing only the high byte of the SOC register. The low byte provides additional resolution in units 1/256%. The reported SOC also includes residual capacity, which might not be available to the actual application because of early termination voltage requirements. When SOC() = 0, typical applications have no remaining capacity. The first update occurs within 250ms after POR of the IC. Subsequent updates occur at variable intervals depending on application conditions. ModelGauge calculations outside the register are clamped at minimum and maximum register limits. Figure 4 shows the SOC register format. Table 2. MODE Register Commands VALUE COMMAND 4000h Quick-Start 210 29 28 27 26 See the Quick-Start description section. MODE Register The MODE register allows the host processor to send special commands to the IC (Table 2). Valid MODE register write values are listed as follows. All other MODE register values are reserved. VERSION Register The VERSION register is a read-only register that contains a value indicating the production version of the MAX17043/MAX17044. CONFIG Register The CONFIG register compensates the ModelGauge algorithm, controls the alert interrupt feature, and forces the IC into Sleep mode through software. The format of CONFIG is shown in Figure 5. CONFIG CONFIG is an 8-bit value that can be adjusted to optimize IC performance for different lithium chemistries or different operating temperatures. Contact Maxim for instructions for optimization. The power-up default value for CONFIG is 97h. MSB—ADDRESS 02h 211 DESCRIPTION LSB—ADDRESS 03h 25 MSB 24 23 LSB MSB 22 21 20 0 0 0 0 LSB UNITS: 1.25mV FOR MAX17043 2.50mV FOR MAX17044 0: BITS ALWAYS READ LOGIC 0 Figure 3. VCELL Register Format MSB—ADDRESS 04h 27 26 25 24 MSB 23 22 LSB—ADDRESS 05h 21 20 2-1 LSB MSB 2-2 2-3 2-4 2-5 2-6 2-7 2-8 LSB UNITS: 1.0% Figure 4. SOC Register Format 8 Compact, Low-Cost 1S/2S Fuel Gauges with Low-Battery Alert LSB—ADDRESS 0Dh RCOMP RCOMP RCOMP RCOMP RCOMP RCOMP RCOMP RCOMP 27 26 25 24 23 22 21 20 MSB LSB SLEEP X ALRT ATHD ATHD 24 23 ATHD ATHD 22 21 MSB ATHD 20 LSB ATHD UNITS: 1 LSB = 2’S COMPLEMENT 1% ATHD RANGE: 11111b = 1% 00000b = 32% Figure 5. CONFIG Register Format SLEEP (Sleep Bit) ATHD (Alert Threshold) Writing SLEEP to logic 1 forces the ICs into Sleep mode. Writing SLEEP to logic 0 forces the ICs to exit Sleep mode. The power-up default value for SLEEP is logic 0. The alert threshold is a 5-bit value that sets the state of charge level where an interrupt is generated on the ALRT pin. The alert threshold has an LSb weight of 1% and can be programmed from 1% up to 32%. The threshold value is stored in two’s-complement form (00000 = 32%, 00001 = 31%, 00010 = 30%, 11111 = 1%). The power-up default value for ATHD is 4% or 1Ch. X (Don't Care) This bit reads as either a logic 0 or logic 1. This bit cannot be written. ALRT (ALERT Flag) This bit is set by the IC when the SOC register value falls below the alert threshold setting and an interrupt is generated. This bit can only be cleared by software. The power-up default value for ALRT is logic 0. COMMAND Register The COMMAND register allows the host processor to send special commands to the IC. Valid COMMAND register write values are listed as follows. All other COMMAND register values are reserved. Table 3 shows COMMAND register commands. Application Examples Table 3. COMMAND Register Commands VALUE COMMAND 5400h POR The MAX17043/MAX17044 have a variety of configurations, depending on the application. Table 4 shows the most common system configurations and the proper pin connections for each. DESCRIPTION See the Power-On Reset (POR) section. Table 4. Possible Application Configurations SYSTEM CONFIGURATION IC VDD ALRT QSTRT 1S Pack-Side Location MAX17043 Power directly from battery Leave unconnected Connect to GND 1S Host-Side Location MAX17043 Power directly from battery Leave unconnected Connect to GND Connect to GND 1S Host-Side Location, Low Cell Interrupt MAX17043 Power directly from battery Connect to system interrupt 1S Host-Side Location, Hardware Quick-Start MAX17043 Power directly from battery Leave unconnected Connect to rising-edge reset signal 2S Pack-Side Location MAX17044 Power from +2.5V to +4.5V LDO in pack Leave unconnected Connect to GND 2S Host-Side Location MAX17044 Power from +2.5V to +4.5V LDO or PMIC Leave unconnected Connect to GND 2S Host-Side Location, Low Cell Interrupt MAX17044 Power from +2.5V to +4.5V LDO or PMIC Connect to system interrupt Connect to GND 2S Host-Side Location, Hardware Quick-Start MAX17044 Power from +2.5V to +4.5V LDO or PMIC Leave unconnected Connect to rising-edge reset signal 9 MAX17043/MAX17044 MSB—ADDRESS 0Ch MAX17043/MAX17044 Compact, Low-Cost 1S/2S Fuel Gauges with Low-Battery Alert BATTERY SYSTEM SYSTEM VDD PACK+ 150Ω 1kΩ 4.7kΩ SYSTEM µP CELL VDD INTERRUPT INPUT ALRT MAX17043 PROTECTION IC (Li+/POLYMER) 1µF QSTRT CTG SDA GND SCL EP I2C BUS MASTER 10nF SYSTEM GND PACK- Figure 6. MAX17043 Application Example with Alert Interrupt BATTERY SYSTEM SYSTEM VDD PACK+ 1kΩ SYSTEM PMIC CELL VDD QSTRT 3.3V OUTPUT WATCHDOG MAX17044 PROTECTION IC (Li+/POLYMER) 1µF ALRT SDA CTG SCL GND PACK- EP I2C BUS MASTER SYSTEM µP SYSTEM GND Figure 7. MAX17044 Application Example with Hardware Reset Figure 6 shows an example application for a 1S cell pack. The MAX17043 is mounted on the system side and powered directly from the cell pack. The external RC networks on VDD and CELL provide noise filtering of the IC power supply and A/D measurement. In this example, the ALRT pin is connected to the microprocessor's interrupt input to allow the MAX17043 to signal when the battery is low. The QSTRT pin is unused in this application, so it is tied to GND. 10 Figure 7 shows a MAX17044 example application using a 2S cell pack. The MAX17044 is mounted on the system side and powered from a 3.3V supply generated by the system. The CELL pin is still connected directly to PACK+ through an external noise filter. The ALRT pin is left unconnected because the interrupt feature is not used in this application. After power is supplied, the system watchdog generates a low-to-high transition on the QSTRT pin to signal the MAX17044 to perform a quick-start. Compact, Low-Cost 1S/2S Fuel Gauges with Low-Battery Alert The 2-wire bus system supports operation as a slaveonly device in a single or multislave, and single or multimaster system. Slave devices can share the bus by uniquely setting the 7-bit slave address. The 2-wire interface consists of a serial-data line (SDA) and serialclock line (SCL). SDA and SCL provide bidirectional communication between the MAX17043/MAX17044 slave device and a master device at speeds up to 400kHz. The MAX17043/MAX17044s’ SDA pin operates bidirectionally; that is, when the MAX17043/MAX17044 receive data, SDA operates as an input, and when the MAX17043/MAX17044 return data, SDA operates as an open-drain output, with the host system providing a resistive pullup. The MAX17043/MAX17044 always operate as a slave device, receiving and transmitting data under the control of a master device. The master initiates all transactions on the bus and generates the SCL signal, as well as the START and STOP bits, which begin and end each transaction. Bit Transfer One data bit is transferred during each SCL clock cycle, with the cycle defined by SCL transitioning lowto-high and then high-to-low. The SDA logic level must remain stable during the high period of the SCL clock pulse. Any change in SDA when SCL is high is interpreted as a START or STOP control signal. Bus Idle The bus is defined to be idle, or not busy, when no master device has control. Both SDA and SCL remain high when the bus is idle. The STOP condition is the proper method to return the bus to the idle state. START and STOP Conditions The master initiates transactions with a START condition (S) by forcing a high-to-low transition on SDA while SCL is high. The master terminates a transaction with a STOP condition (P), a low-to-high transition on SDA while SCL is high. A Repeated START condition (Sr) can be used in place of a STOP then START sequence to terminate one transaction and begin another without returning the bus to the idle state. In multimaster systems, a Repeated START allows the master to retain control of the bus. The START and STOP conditions are the only bus activities in which the SDA transitions when SCL is high. Acknowledge Bits Each byte of a data transfer is acknowledged with an acknowledge bit (A) or a no-acknowledge bit (N). Both the master and the MAX17043 slave generate acknowledge bits. To generate an acknowledge, the receiving device must pull SDA low before the rising edge of the acknowledge-related clock pulse (ninth pulse) and keep it low until SCL returns low. To generate a noacknowledge (also called NAK), the receiver releases SDA before the rising edge of the acknowledge-related clock pulse and leaves SDA high until SCL returns low. Monitoring the acknowledge bits allows for detection of unsuccessful data transfers. An unsuccessful data transfer can occur if a receiving device is busy or if a system fault has occurred. In the event of an unsuccessful data transfer, the bus master should reattempt communication. Data Order A byte of data consists of 8 bits ordered most significant bit (MSb) first. The least significant bit (LSb) of each byte is followed by the acknowledge bit. The MAX17043/MAX17044 registers composed of multibyte values are ordered MSb first. The MSb of multibyte registers is stored on even data-memory addresses. Slave Address A bus master initiates communication with a slave device by issuing a START condition followed by a slave address (SAddr) and the read/write (R/W) bit. When the bus is idle, the MAX17043/MAX17044 continuously monitor for a START condition followed by its slave address. When the MAX17043/MAX17044 receive a slave address that matches the value in the slave address register, they respond with an acknowledge bit during the clock period following the R/W bit. The 7-bit slave address is fixed to 6Ch (write)/ 6Dh (read): MAX17043/MAX17044 SLAVE ADDRESS 0110110 Read/Write Bit The R/W bit following the slave address determines the data direction of subsequent bytes in the transfer. R/W = 0 selects a write transaction, with the following bytes being written by the master to the slave. R/W = 1 selects a read transaction, with the following bytes being read from the slave by the master. (Table 5). 11 MAX17043/MAX17044 2-Wire Bus System MAX17043/MAX17044 Compact, Low-Cost 1S/2S Fuel Gauges with Low-Battery Alert Table 5. 2-Wire Protocol Key KEY DESCRIPTION KEY DESCRIPTION S START bit Sr Repeated START SAddr Slave address (7 bit) W R/W bit = 0 MAddr Memory address byte P STOP bit Data Data byte written by master Data Data byte returned by slave A Acknowledge bit—master A Acknowledge bit—slave N No acknowledge—master N No acknowledge—slave Bus Timing The MAX17043/MAX17044 are compatible with any bus timing up to 400kHz. No special configuration is required to operate at any speed. 2-Wire Command Protocols The command protocols involve several transaction formats. The simplest format consists of the master writing the START bit, slave address, R/W bit, and then monitoring the acknowledge bit for presence of the MAX17043/MAX17044. More complex formats, such as the Write Data and Read Data, read data and execute device-specific operations. All bytes in each command format require the slave or host to return an acknowledge bit before continuing with the next byte. Table 5 shows the key that applies to the transaction formats. Basic Transaction Formats Write: S. SAddr W. A. MAddr. A. Data0. A. Data1. A. P A write transaction transfers 2 or more data bytes to the MAX17043/MAX17044. The data transfer begins at the memory address supplied in the MAddr byte. Control of the SDA signal is retained by the master throughout the transaction, except for the acknowledge cycles: Read: S. SAddr W. A. MAddr. A. Sr. SAddr R. A. Data0. A. Data1. N. P Write Portion Read Portion A read transaction transfers 2 or more bytes from the MAX17043/MAX17044. Read transactions are composed of two parts, a write portion followed by a read portion, and are therefore inherently longer than a write transaction. The write portion communicates the starting point for the read operation. The read portion follows immediately, beginning with a Repeated START, slave address with R/W set to a 1. Control of SDA is assumed 12 by the MAX17043/MAX17044, beginning with the slave address acknowledge cycle. Control of the SDA signal is retained by the MAX17043/MAX17044 throughout the transaction, except for the acknowledge cycles. The master indicates the end of a read transaction by responding to the last byte it requires with a no acknowledge. This signals the MAX17043/MAX17044 that control of SDA is to remain with the master following the acknowledge clock. Write Data Protocol The write data protocol is used to write to register to the MAX17043/MAX17044 starting at memory address MAddr. Data0 represents the data written to MAddr, Data1 represents the data written to MAddr + 1, and DataN represents the last data byte, written to MAddr + N. The master indicates the end of a write transaction by sending a STOP or Repeated START after receiving the last acknowledge bit: SAddr W. A. MAddr. A. Data0. A. Data1. A... DataN. A The MSB of the data to be stored at address MAddr can be written immediately after the MAddr byte is acknowledged. Because the address is automatically incremented after the LSB of each byte is received by the MAX17043/MAX17044, the MSB of the data at address MAddr + 1 can be written immediately after the acknowledgment of the data at address MAddr. If the bus master continues an autoincremented write transaction beyond address 4Fh, the MAX17043/ MAX17044 ignore the data. A valid write must include both register bytes. Data is also ignored on writes to read-only addresses. Incomplete bytes and bytes that are not acknowledged by the MAX17043/MAX17044 are not written to memory. Compact, Low-Cost 1S/2S Fuel Gauges with Low-Battery Alert S. SAddr W. A. MAddr. A. Sr. SAddr R. A. Data0. A. Data1. A... DataN. N. P Data is returned beginning with the MSB of the data in MAddr. Because the address is automatically incremented after the LSB of each byte is returned, the MSB of the data at address MAddr + 1 is available to the host immediately after the acknowledgment of the data at address MAddr. If the bus master continues to read beyond address FFh, the MAX17043/MAX17044 output data values of FFh. Addresses labeled Reserved in the memory map return undefined data. The bus master terminates the read transaction at any byte boundary by issuing a no acknowledge followed by a STOP or Repeated START. Package Information For the latest package outline information and land patterns (footprints), go to www.maxim-ic.com/packages. Note that a “+”, “#”, or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package regardless of RoHS status. PACKAGE TYPE PACKAGE CODE OUTLINE NO. LAND PATTERN NO. 8 TDFN T823+1 21-0174 90-0091 9 UCSP W91C1+1 21-0459 Refer to Application Note 1891 13 MAX17043/MAX17044 Read Data Protocol The read data protocol is used to read to register from the MAX17043/MAX17044 starting at the memory address specified by MAddr. Both register bytes must be read in the same transaction for the register data to be valid. Data0 represents the data byte in memory location MAddr, Data1 represents the data from MAddr + 1, and DataN represents the last byte read by the master: MAX17043/MAX17044 Compact, Low-Cost 1S/2S Fuel Gauges with Low-Battery Alert Revision History REVISION NUMBER REVISION DATE 0 9/09 Initial release 1 4/10 Updated soldering temperature information; updated CTG pin voltage range to from 0.3V to +12V to -0.3V to +12V in Absolute Maximum Ratings section; removed future asterisks in ordering table; changed update time for SOC and VCELL; changed registers from 110ms/440ms to 125ms/500ms 2 9/10 Added description and ordering information for UCSP package type 3 10/10 DESCRIPTION PAGES CHANGED — 1, 2, 8 1, 2, 3, 5, 13, 14 Updated Ordering Information table 1, 2, 13,14 4, 6, 8, 14 4 8/11 Corrected time from start up until SOC valid; added text indicating accurate results require custom configuration for each application 5 6/12 Corrected soldering temperature in Absolute Maximum Ratings 2 Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance. 14 _______________Maxim Integrated Products, Inc. 160 Rio Robles, San Jose, CA 95134 USA 1-408-601-1000 © 2012 Maxim Integrated Products Maxim is a registered trademark of Maxim Integrated Products, Inc.