DYELEC HER303 3 .0 amp. high efficient rectifier Datasheet

HER301 THRU HER308
3 .0 AMP. High Efficient Rectifiers
Features
· Low forward voltage drop
DO-201AD
· High current capability
· High reliability
· High surge current capability
· Plastic material-UL flammability 94V-0
0.96(24.5)
MIN.
DIA.
Mechanical Data
· Case: Molded plastic DO-201AD
· Terminals: Plated leads solderable per
MIL-STD-202,Method 208 guaranteed
· Polarity: Color band dentes cathode end
0.96(24.5)
DIA.
MIN.
· Mounting Position: Any
· Making: Type Number
· Lead Free: For RoHS/Lead Free Version
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ ambient temperature unless otherwise specified
Single phase,half wave,60Hz,resistive or inductive load
For capacitive load derate current by 20%
SYMBOL
HER
301
HER
302
HER
303
HER
304
HER
305
HER
306
HER
307
HER
308
Unit
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
300
400
600
800
1000
V
Maximum RMS Voltage
VRMS
35
70
140
210
280
420
630
700
V
Maximum DC Blocking Voltage
VDC
50
100
200
300
400
600
800
1000
V
Type Number
Maximum Average Forward Rectified
Current.375"(9.5mm) lead length@TA=55℃
IO
3.0
A
Peak Forward Surge Current 8.3ms Single
half sine-wave superimposed on rated load
(JEDEC Method)
IFSM
125
A
Forward Voltage
VFM
@IF=3.0A
Peak Reverse Current
@TA=25℃
At Rated DC Blocking Voltage @TA=100℃
1.3
1.0
1.7
5.0
IR
uA
100
Typical Junction Capacitance (Note 1)
CJ
Typical Thermal Resistance Junction to
Ambient(Note 2)
RθJA
Maximum Reverse Recovery Time(Note 3)
Trr
Operating Temperature Range
TJ
-55 to +125
℃
TSTG
-55 to +150
℃
/Storage Temperature Range
50
V
30
75
Note: 1. Measured at 1.0 MHz and Applied reverse Voltage of 4.0V D.C
2. Leads maintained at ambient temperature at a distance of 9.5mm from the case
3.Reverse Recovery Test Conditions: IF=0.5A, IR=1A, Irr=0.25A
version:01
℃ /W
25
50
1of2
www.dyelec.com
pF
ns
HER301 THRU HER308
FIG.2- TYPICAL FORWARD CHARACTERISTICS
INSTANTANEOUS FORWARD CURRENT, (A)
2.0
1.0
SINGLE PHASE HALF WAVE 60Hz
RESISTIVE OR INDUCTIVE LOAD
0
25
50
75
100
125
150
175
R3
04
HE
T A =25 0C
10
R3
01
~
3.0
100
HE
AVERAGE FORWARD CURRENT ( A )
FIG.1- MAXIMUM AVERAGE
FORWARD CURRENT DERATING
HE
R3
05
8
30
1
ER
H
6~
0
R3
HE
0.1
0.01
0
0.2
0.6
0.4
0.8
1.0
1.2
1.4
AMBIENT TEMPERATURE (°C)
INSTANTANEOUS FORWARD VOLTAGE (V)
FIG.4- TYPICAL JUNCTION CAPACITANCE
225
175
200
150
175
CAPACITANCE (pF)
PEAK FORWARD SURGE CURRENT,( A )
FIG.3- MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
150
125
100
75
50
HE
100
R3
75
01
~H
ER
30
HE
R3
06~
HE
50
5
R3
08
25
25
0
125
0
1
10
100
1000
NUMBER OF CYCLES AT 60Hz
version:01
0.1
0.5
1
2
5
10
20
50
REVERSE VOLTAGE (V)
2of2
www.dyelec.com
100 200
500