Sensortechnics BTEM6350A0CXS Submersible precision stainless steel transmitter Datasheet

BTE6000 / PTU6000...CS Series
Submersible precision stainless steel transmitters
FEATURES
· 0...100 mbar to 0...10 bar, 0...2 to 0...150 psi
gage or absolute
· For corrosive media
· 0...10 V, 1...6 V, 0...20 mA or 4...20 mA
output
· Field interchangeable
· For harsh environments
MEDIA COMPATIBILITY
Wetted materials:
stainless steel 1.4404 (316L), PVC, PUR, NBR11
Housing:
protection class IP 68 (according to DIN EN 60529)
respectively NEMA 6P1
ELECTRICAL CONNECTION
0...10 V, 1...6 V output
sensor
SPECIFICATIONS9,10
Maximum ratings
Supply voltage (reverse polarity protection)
13...30 V
BTE(M)/PTU6...0..., 1...
12...36 V
BTE(M)/PTU6...4..., 5...2
Maximum load current
BTE(M)/PTU6...0..., 1...
Temperature limits
Storage
Operating
Compensated
Vibration (5 to 500 Hz)
Mechanical shock
Proof pressure3
August 2008 / 104
V
GND
0...20 mA output
10 mA
+Vs
red
Iout
blue
-Vs
black
12 to 36 V
RL
4...20 mA output
10 gRMS
sensor
V
GND
bare
-40 to 85°C
-25 to 85°C
0 to 70°C
2 x rated pressure
13 to 30 V
bare
sensor
50 g
+Vs
red
Vout
yellow
-Vs
black
+Vs
red
12 to 36 V
V
-Vs
black
RL
GND
bare
1/6
www.sensortechnics.com
BTE6000 / PTU6000...CS Series
Submersible precision stainless steel transmitters
COMMON PERFORMANCE CHARACTERISTICS1
Characteristics
Operating pressure
4
Thermal effects (0 to 70°C)
(-25 to 0°C, 70 to 85°C)
Min.
Typ.
BTEM6100...
0
100
BTEM6250...
0
250
BTEM6350...
0
350
BTEM6500...
0
500
BTE6001...
0
1
BTE6002...
0
2
BTE6005...
0
5
BTE6010...
0
10
PTU6002...
0
2
PTU6003...
0
3
PTU6005...
0
5
PTU6010...
0
10
PTU6015...
0
15
PTU6030...
0
30
PTU6050...
0
50
PTU6100...
0
100
PTU6150...
0
150
Offset
0.02
0.04
Span
0.02
0.04
Offset
0.03
Span
0.03
5
Non-linearity and hysteresis (BSL)
±0.1
Repeatability
±0.1
6
Long term stability
±0.2
Output noise (0 < f < 1 kHz)
±0.04
Response time (10 to 90 %)
1
Power supply rejection
August 2008 / 104
Max.
Offset
0.05
Span
0.05
Unit
mbar
bar
p si
%FSO/°C
0.25
%FSO
ms
%FSO/V
2/6
www.sensortechnics.com
BTE6000 / PTU6000...CS Series
Submersible precision stainless steel transmitters
INDIVIDUAL PERFORMANCE CHARACTERISTICS1
0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset
Min.
Typ.
Max.
-0.15
0
0.15
9.9
10.0
10.1
7
Full scale span
Output impedance
50
Power consumption (no load)
100
Unit
V
Ω
mW
1...6 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Min.
Typ.
Max.
Zero pressure offset
0.85
1.0
1.15
Full scale span7
4.9
5.0
5.1
Full scale output
Unit
V
6.0
Output impedance
50
Power consumption (no load)
100
Ω
mW
4...20 mA output (VS = 15 V, RL > 100 Ω, tamb = 25°C)
Characteristics
Zero pressure offset
7
Full scale span
Min.
Typ.
Max.
3.85
4.0
4.15
15.9
16.0
16.1
Unit
mA
Output impedance
0.1
Ω
Power consumption (IL = 20 mA)
260
mW
0...20 mA output (VS = 15 V, RL > 100 Ω, tamb = 25°C)
Characteristics
Zero pressure offset
7
Full scale span
Min.
Typ.
Max.
-0.15
0
0.15
19.9
20.0
20.1
Unit
mA
Output impedance
0.1
Ω
Power consumption (IL = 20 mA)
260
mW
August 2008 / 104
3/6
www.sensortechnics.com
BTE6000 / PTU6000...CS Series
Submersible precision stainless steel transmitters
ELECTROMAGNETIC CAPABILITY8
Test conditions
Criterion
Interference
Grade 3
10 V/m, 80 MHz to 1000 MHz
80 % AMC (1 kHz)
A
<1 % FSO
Radiated, radio frequency
electromagnetic field
immunity (RFI)
EN61000-4-3:
Electrical fast transient /
burst immunity (EFT)
EN61000-4-4:
Grade 3
±2 kV
B
<1 % FSO
Electrostatic discharge
immunity test (ESD)
EN61000-4-2:
Grade 4
±8 kV, contact discharge
B
<1 % FSO
Immunity to conducted
disturbances induced by
radio-frequency fields
EN61000-4-6:
Grade 3
0,15 to 80 MHz
10 V, 80 % AMC (1 kHz)
A
<1 % FSO
Specification notes (for all devices):
The package is a all-sealed housing. Gage devices are vented through an integral PE tube of the connecting cable.
The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagrams.
3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
4. Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C.
5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span.
6. Long term stability is the change in output after one year or 1 million pressure cycles.
7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure.
8. Test are in accordance with EN61000-6-2, April 1999.
9. CE-labelling is in accordance with 89/336/EEC.
10. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
11. Other sealing materials are available on request.
1.
2.
August 2008 / 104
4/6
www.sensortechnics.com
BTE6000 / PTU6000...CS Series
Submersible precision stainless steel transmitters
OUTPUT CHARACTERISTICS
Voltage output versions
Current output versions
Vout 10
V 9
lout 20
mA 18
8
16
7
14
6
12
BTE(M)/PTU6...0...
5
BTE(M)/PTU6...4...
BTE(M)/PTU6...5...
10
4
8
BTE(M)/PTU6...1...
3
6
2
4
1
2
0
20
40
60
80
100 %
operating pressure
0
20
40
60
80
100 %
operating pressure
LOAD LIMITATION
0...20 mA output version
4...20 mA ouput version
1400
Ohm
1200
1000
800
600
operating
range
400
200
0
5
10
15
20
25
30
35 V
supply voltage
August 2008 / 104
5/6
www.sensortechnics.com
BTE6000 / PTU6000...CS Series
Submersible precision stainless steel transmitters
OUTLINE DRAWING
NOM 151
(5.95)
NOM 70
(2.76)
NOM 2000
(78.74)
Ø 27
(1.06)
Ø 24
(0.95)
other cable lengths
on request
Hydrophobic filter
(incl. in delivery)
mass: typ. 350 g (without cable)
dimensions in mm (inches)
ORDERING INFORMATION
BTE/PTU
M
6xxx
x
x
C
x
S
calibration
submersible
BTE: calibration in bar
PTU: calibration in psi
cable length in m
mbar-ranges
cable version
pressure range
output signal
100:
250:
350:
500:
001:
002:
005:
010:
0...100
0...250
0...350
0...500
mbar
mbar
mbar
mbar
0...1 bar
0...2 bar
0...5 bar
0...10 bar
Note:
002:
0...2 psi
003:
0...3 psi
005:
0...5 psi
010: 0...10 psi
015: 0...15 psi
030: 0...30 psi
050: 0...50 psi
100: 0...100 psi
150: 0...150 psi
0:
1:
4:
5:
0...10 V
1...6 V
4...20 mA
0...20 mA
pressure mode
G: gage pressure
A: absolute pressure
(available for pressure
ranges from 1 bar/15 psi
absolute upwards only!)
Other pressure ranges and options are widely available.
Please contact your nearest Sensortechnics sales representative.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
August 2008 / 104
6/6
www.sensortechnics.com