IVO NE230.113AX01 Preset counters electronic Datasheet

Preset counters electronic
2 presets, DIN rail housing
Display LED, 6-digits, programmable
NE230
Features
–– Preset counter with two presets
–– Display 6-digits
–– Mousing for control cabinet installation
–– Totalizer, hour counter
–– Operating mode, start count, scaling factor
programmable
–– Connection: Incremental encoder or digital sensors
–– Preset mode programmable
–– Interface RS232 or RS422/RS485
NE230 - LED Preset counter
Technical data - electrical ratings
Technical data - electrical ratings
Voltage supply
14...28 VAC (50/60 Hz)
85...265 VAC (50/60 Hz)
10...30 VDC
Programmable
parameters
Power consumption
5 VA, 4 W
Sensor supply
18 VDC ±15 % / 100 mA
Operating modes
Sensor logic
Scaling factor
Count mode
Control inputs
Display
LED, 7-segment display
Approvals
UL/cUL, CE conform
Number of digits
6-digits
Digit height
7.6 mm
Function
Preset counter
Main counter with 2 presets
Totalizer
Hour counter
-20...+70 °C
Relative humidity
80 % non-condensing
E-connection
Plug-in screw terminals
D-SUB-female connector, 9-pin
(interface)
Core cross-section
1.5 mm²
Protection DIN EN 60529
IP 50 face DIN 0470-1
Operation / keypad
Membrane with softkeys
3 Hz, 25 Hz, 10 kHz
programmable
Housing type
Surface mount housing
Step preset, Main preset,
Parallel alignment, Trailing
preset
Dimensions W x H x L
70 x 89 x 58 mm
Installation depth
58 mm
Mounting
DIN rail housing EN 50022
Materials
Housing: GFV Polycarbonat
Rear: PPO
Keypad: Polyester
Weight approx.
300 g
0.0001...9999.99
Count modes
Adding or subtracting
A-B (difference counting)
A+B total (parallel counting)
Up/Down
A 90° B phase evaluation
Operating modes
Data memory
>10 years in EEPROM
Reset
Button, electric or automatic
Keylock
Yes, electric (keylock)
Outputs relay
Normally open or closed,
programmable
Output holding time
0.01...99.99 s
Interfaces
RS232, RS422, RS485
Standard
DIN EN 61010‑1
Protection class II
Overvoltage category II
Pollution degree 2
Emitted interference
DIN EN 61000-6-3
Interference immunity
DIN EN 61000-6-2
1
www.baumerivo.com
Subject to modification in technic and design. Errors and omissions excepted.
0...+50 °C
Storing temperature
30/10/2008
Operating temperature
Scaling factor
Counting frequency
Technical data - mechanical design
Preset counters electronic
2 presets, DIN rail housing
Display LED, 6-digits, programmable
NE230
Part number
1
AX01
Voltage
supply
Voltage supply
2 85...265 VAC
3 14...28 VAC / 10...30 VDC
-
1
+
2
Signal input
A
B
Outputs
1 Relay outputs
7
9
10
A 90° B
2
1
P1
RS232
8
1
Shield
6
RS485
3
TxD+
5
+5V
3
T,R-
1
GND
Sensor
supply
max. 250 V
terminal - terminal /
- terminal
4
5
8
9
RxD-
P2
3
TxD-
4
GND
5
Supply voltage
6
RxD+
+18V 0V
P1
4
5
11
Stop/Hold 2
12
Operating
time meter
Interface
RS485/RS422
RS232
Trigger level
T,R+
5
7
Shield
Track A
Track B
Signal
input
3
TxD
Shield
2
RxD
1
GND
1
Control
input
2
8
3
Main counter with
2 presets
start count
scaling factor
6
Control input
1
Reset
Comparator inputs
9
+
Output
9-pin
SUB-D
plug
Connection diagram
11 10
8
Totalizer
P2
Interface
0 Without interface
1 RS422 / RS485
2 RS232
12
Sensor
supply
-
Input circuit
Inputs
PNP- / NPN- / AC-logic
Input level
Programmable
Input level Low
0...2 VDC
Input level High
3...40 VDC
Input resistance
3 kΩ
Relay outputs
Output circuit
Switching voltage max.
250 VAC / 110 VDC
Switching current max.
1A
Switching capacity max.
150 VA / 30 W
Relay responding time
5 ms
RS422
70
65.8
Subject to modification in technic and design. Errors and omissions excepted.
Dimensions
99
46
60
86
24.7
35
41.8
D-SUB
9
29
48
58
2
www.baumerivo.com
30/10/2008