EPCOS B41888C8227M000 Aluminum electrolytic capacitor Datasheet

Aluminum electrolytic capacitors
Single-ended capacitors
Series/Type:
B41888
Date:
November 2008
© EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
Single-ended capacitors
B41888
Extended useful life 105 °C
Long-life grade capacitors
Very low impedance
Applications
Automotive electronics
For use in switch-mode power supplies
For professional industrial electronics, telecommunications
and data processing equipment
Features
Long useful life
Very low impedance at high frequency
High ripple current capability
RoHS-compatible
Construction
Radial leads
Charge-discharge proof, polar
Aluminum case with insulating sleeve
Minus pole marking on the insulating sleeve
Case with safety vent
Delivery mode
Terminal configurations and packing:
Bulk
Taped, Ammo pack
Cut
Kinked
PAPR (protection against polarity reversal):
crimped leads, J leads, bent leads
Refer to chapter "Single-ended capacitors Taping, packing
and lead configurations" for further details and ordering
example.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 32
B41888
Extended useful life 105 °C
Specifications and characteristics in brief
Rated voltage VR
Surge voltage VS
Rated capacitance CR
Capacitance tolerance
10 ... 63 V DC
1.15 VR
56 ... 10000 µF
±20% M
Dissipation factor tan δ
(20 °C, 120 Hz)
For capacitance higher than 1000 µF add 0.02 for every increase of
1000 µF.
Leakage current Ileak
(20 °C, 5 min)
Self-inductance ESL
Useful life
105 °C; VR; IAC,R
Requirements
Voltage endurance test
105 °C; VR
VR (V DC)
tan δ (max.)
10
0.18
16
0.16
25
0.14
Diameter (mm)
≤12.5
16
18
ESL (nH)
20
26
34
35
0.12
50
0.10
63
0.09
> 5000 h for d = 8 mm
> 7000 h for d = 10 mm
> 10000 h for d ≥ 12.5 mm
∆C/C
tan δ
Ileak
≤ ±40% of initial value
≤ 3 times initial specified limit
≤ initial specified limit
5000 h for d = 8 mm
7000 h for d = 10 mm
10000 h for d ≥ 12.5 mm
Post test requirements
∆C/C
tan δ
Ileak
Vibration resistance test
To IEC 60068-2-6, test Fc:
Displacement amplitude 1.5 mm, frequency range 10 … 2000 Hz,
acceleration max. 20 g, duration 3 × 2 h.
Capacitor rigidly clamped by the aluminum case.
IEC climatic category
To IEC 60068-1:
55/105/56 (55 °C/+105 °C/56 days damp heat test)
Sectional specification
AEC-Q200, IEC 60384-4
Please read Cautions and warnings and
Important notes at the end of this document.
≤ ±30% of initial value
≤ 2 times initial specified limit
≤ initial specified limit
Page 3 of 32
B41888
Extended useful life 105 °C
Dimensional drawings
With stand-off rubber seal
Diameters (mm): 10, 12.5, 16, 18
With flat rubber seal
Diameter (mm): 8
Dimensions and weights
Dimensions (mm)
d +0.5
8
10
10
10
12.5
12.5
12.5
16
16
16
18
18
18
18
18
l
11.5 +1.5
12.5 +1.0
16 +1.0
20 +2.0
20 +2.0
25 +2.0
40 +2.0
20 +2.0
25 +2.0
31.5 +2.0
20 +2.0
25 +2.0
31.5 +2.0
35 +2.0
40 +2.0
Please read Cautions and warnings and
Important notes at the end of this document.
a ±0.5
3.5
5.0
5.0
5.0
5.0
5.0
5.0
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
Page 4 of 32
b
0.60 ±0.05
0.60 ±0.05
0.60 ±0.05
0.60 ±0.05
0.60 ±0.05
0.60 ±0.05
0.80 ±0.05
0.80 ±0.05
0.80 ±0.05
0.80 ±0.05
0.80 ±0.1
0.80 ±0.1
0.80 ±0.1
0.80 ±0.1
0.80 ±0.1
Approx. weight
g
1.0
1.6
1.9
2.6
3.6
4.5
7.4
5.5
7.5
7.8
8.0
9.0
11.0
13.0
16.0
B41888
Extended useful life 105 °C
Overview of available types
VR (V DC)
10
16
25
35
50
63
Case dimensions d × l (mm)
CR (µF)
56
8
× 11.5
68
8
× 11.5
10
× 12.5
100
8
× 11.5
10
× 12.5
120
8
× 11.5
10
× 16
10
× 12.5
10
× 16
10
× 20
× 20
82
150
8
× 11.5
180
10
× 12.5
220
8
× 11.5
10
× 12.5
10
× 16
10
270
8
× 11.5
10
× 12.5
10
× 20
12.5 × 20
10
× 16
10
× 20
12.5 × 20
330
8
× 11.5
10
× 12.5
390
8
× 11.5
10
× 12.5
12.5 × 25
470
8
× 11.5
10
× 12.5
10
× 16
10
× 20
12.5 × 20
16
× 20
560
10
× 12.5
10
× 16
10
× 16
10
× 20
12.5 × 25
16
× 20
680
10
× 12.5
10
× 16
10
× 20
10
× 20
12.5 × 25
12.5 × 40
16 × 25
18 × 20
820
10
× 16
10
× 20
12.5 × 20
16
1000
10
× 16
10
× 20
12.5 × 20
12.5 × 25
12.5 × 40
16 × 25
18 × 20
1200
10
× 20
10
× 20
12.5 × 20
16
1500
10
× 20
12.5 × 20
12.5 × 25
1800
10
× 20
12.5 × 25
16
× 20
12.5 × 40
16 × 25
18 × 20
2200
12.5 × 20
12.5 × 25
18
× 20
16
18
2700
12.5 × 25
16
12.5 × 40
16 × 25
3300
12.5 × 25
3900
16
× 20
× 20
12.5 × 40
16 × 25
18 × 20
Please read Cautions and warnings and
Important notes at the end of this document.
× 20
16
18
× 31.5
× 25
16
18
× 31.5
× 25
18
× 31.5
16
× 31.5
18
× 35
18
× 31.5
18
× 40
× 31.5
× 25
18
× 35
16
× 31.5
18
× 40
16
18
× 31.5
× 25
18
× 31.5
18
× 31.5
18
× 35
Page 5 of 32
× 20
B41888
Extended useful life 105 °C
VR (V DC)
10
16
25
35
50
Case dimensions d × l (mm)
CR (µF)
4700
16
× 25
16
18
× 31.5
× 25
18
× 35
5600
12.5 × 40
16 × 25
18 × 20
18
× 31.5
18
× 40
6800
16
18
× 31.5
× 25
8200
18
× 31.5
18
× 35
10000
18
× 35
18
× 40
18
× 40
Other voltage and capacitance ratings are available upon request.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 6 of 32
63
B41888
Extended useful life 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
VR = 10 V DC
470
8 × 11.5
560
10 × 12.5
680
10 × 12.5
820
10 × 16
1000
10 × 16
1200
10 × 20
1500
10 × 20
1800
10 × 20
2200
12.5 × 20
2700
12.5 × 25
3300
12.5 × 25
3900
16 × 20
4700
16 × 25
5600
12.5 × 40
5600
16 × 25
5600
18 × 20
6800
16 × 31.5
6800
18 × 25
8200
18 × 31.5
10000
18 × 35
ESRmax
10 kHz
40 °C
Ω
ESRmax
120 Hz
20 °C
Ω
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
IAC,max
Ordering code
100 kHz (composition see
85 °C
below)
mA
1.630
0.928
0.930
0.512
0.516
0.403
0.400
0.400
0.328
0.240
0.237
0.233
0.190
0.149
0.190
0.226
0.154
0.188
0.143
0.120
0.484
0.406
0.334
0.277
0.227
0.189
0.152
0.126
0.115
0.094
0.084
0.071
0.065
0.059
0.059
0.059
0.052
0.052
0.049
0.045
0.204
0.116
0.116
0.064
0.064
0.050
0.050
0.050
0.041
0.030
0.030
0.029
0.024
0.019
0.024
0.028
0.019
0.023
0.018
0.015
0.183
0.101
0.101
0.059
0.059
0.046
0.046
0.046
0.039
0.027
0.027
0.026
0.022
0.017
0.022
0.025
0.017
0.021
0.016
0.014
690
900
900
1240
1240
1500
1500
1500
2000
2459
2459
2530
2930
3350
2930
3000
3600
3396
4247
4300
966
1260
1260
1736
1736
2100
2100
2100
2800
3443
3442
3542
4102
4690
4102
4200
5040
4755
5946
6020
B41888C3477M***
B41888C3567M***
B41888C3687M***
B41888C3827M***
B41888C3108M***
B41888C3128M***
B41888C3158M***
B41888C3188M***
B41888D3228M***
B41888C3278M***
B41888C3338M***
B41888C3398M***
B41888C3478M***
B41888C3568M***
B41888D3568M***
B41888E3568M***
B41888C3688M***
B41888D3688M***
B41888C3828M***
B41888C3109M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm, excluding 12.5 × 40 mm)
002 = for cut leads, bulk (for ∅ ≥ 10 mm, excluding 12.5 × 40 mm)
003 = for crimped leads, blister (from d × l = 16 × 20 mm to 18 × 40 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm, excluding 12.5 × 40 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 32
B41888
Extended useful life 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
VR = 16 V DC
330
8 × 11.5
390
8 × 11.5
470
10 × 12.5
560
10 × 16
680
10 × 16
1000
10 × 20
1200
10 × 20
1500
12.5 × 20
1800
12.5 × 25
2200
12.5 × 25
2700
16 × 20
3900
12.5 × 40
3900
16 × 25
3900
18 × 20
4700
16 × 31.5
4700
18 × 25
5600
18 × 31.5
8200
18 × 35
10000
18 × 40
ESRmax
10 kHz
40 °C
Ω
ESRmax
120 Hz
20 °C
Ω
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
IAC,max
Ordering code
100 kHz (composition see
85 °C
below)
mA
1.630
1.632
0.930
0.512
0.516
0.403
0.400
0.328
0.240
0.237
0.233
0.149
0.190
0.226
0.154
0.188
0.143
0.120
0.100
0.612
0.518
0.430
0.361
0.297
0.202
0.168
0.135
0.112
0.103
0.084
0.065
0.065
0.065
0.059
0.059
0.054
0.043
0.040
0.204
0.204
0.116
0.064
0.064
0.050
0.050
0.041
0.030
0.030
0.029
0.019
0.024
0.028
0.019
0.023
0.018
0.015
0.013
0.183
0.183
0.101
0.059
0.059
0.046
0.046
0.039
0.027
0.027
0.026
0.017
0.022
0.025
0.017
0.021
0.016
0.014
0.012
690
690
900
1240
1240
1500
1500
2000
2459
2459
2530
3350
2930
3000
3600
3200
4247
4300
5327
966
966
1260
1736
1736
2100
2100
2800
3443
3442
3542
4690
4102
4200
5040
4480
5946
6020
7457
B41888C4337M***
B41888C4397M***
B41888C4477M***
B41888C4567M***
B41888C4687M***
B41888C4108M***
B41888C4128M***
B41888D4158M***
B41888C4188M***
B41888C4228M***
B41888C4278M***
B41888C4398M***
B41888D4398M***
B41888E4398M***
B41888C4478M***
B41888D4478M***
B41888C4568M***
B41888C4828M***
B41888C4109M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm, excluding 12.5 × 40 mm)
002 = for cut leads, bulk (for ∅ ≥ 10 mm, excluding 12.5 × 40 mm)
003 = for crimped leads, blister (from d × l = 16 × 20 mm to 18 × 40 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm, excluding 12.5 × 40 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 32
B41888
Extended useful life 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
VR = 25 V DC
220
8 × 11.5
270
8 × 11.5
330
10 × 12.5
390
10 × 12.5
470
10 × 16
560
10 × 16
680
10 × 20
820
10 × 20
1000
12.5 × 20
1200
12.5 × 20
1500
12.5 × 25
1800
16 × 20
2200
18 × 20
2700
12.5 × 40
2700
16 × 25
3300
16 × 31.5
3300
18 × 25
3900
18 × 31.5
4700
18 × 35
5600
18 × 40
ESRmax
10 kHz
40 °C
Ω
ESRmax
120 Hz
20 °C
Ω
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
IAC,max
Ordering code
100 kHz (composition see
85 °C
below)
mA
1.630
1.632
0.930
0.928
0.516
0.512
0.403
0.400
0.328
0.328
0.237
0.233
0.226
0.149
0.190
0.154
0.188
0.143
0.120
0.100
0.804
0.655
0.536
0.453
0.376
0.316
0.260
0.216
0.177
0.147
0.118
0.098
0.090
0.075
0.075
0.069
0.069
0.058
0.054
0.050
0.204
0.204
0.116
0.116
0.064
0.064
0.050
0.050
0.041
0.041
0.030
0.029
0.028
0.019
0.024
0.019
0.023
0.018
0.015
0.013
0.183
0.183
0.101
0.101
0.059
0.059
0.046
0.046
0.039
0.039
0.027
0.026
0.025
0.017
0.022
0.017
0.021
0.016
0.014
0.012
690
690
900
900
1240
1240
1500
1500
2000
2000
2459
2530
3000
3350
2930
3600
3200
4247
4300
5327
966
966
1260
1260
1736
1736
2100
2100
2800
2800
3442
3542
4200
4690
4102
5040
4480
5946
6020
7457
B41888C5227M***
B41888C5277M***
B41888C5337M***
B41888C5397M***
B41888C5477M***
B41888C5567M***
B41888C5687M***
B41888C5827M***
B41888D5108M***
B41888C5128M***
B41888C5158M***
B41888C5188M***
B41888C5228M***
B41888C5278M***
B41888D5278M***
B41888C5338M***
B41888D5338M***
B41888C5398M***
B41888C5478M***
B41888C5568M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm, excluding 12.5 × 40 mm)
002 = for cut leads, bulk (for ∅ ≥ 10 mm, excluding 12.5 × 40 mm)
003 = for crimped leads, blister (from d × l = 16 × 20 mm to 18 × 40 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm, excluding 12.5 × 40 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 9 of 32
B41888
Extended useful life 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
VR = 35 V DC
150
8 × 11.5
180
10 × 12.5
220
10 × 12.5
270
10 × 12.5
330
10 × 16
470
10 × 20
560
10 × 20
680
10 × 20
820
12.5 × 20
1000
12.5 × 25
1200
16 × 20
1800
12.5 × 40
1800
16 × 25
1800
18 × 20
2200
16 × 31.5
2200
18 × 25
2700
16 × 31.5
3300
18 × 31.5
3900
18 × 35
4700
18 × 40
ESRmax
10 kHz
40 °C
Ω
ESRmax
120 Hz
20 °C
Ω
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
IAC,max
Ordering code
100 kHz (composition see
85 °C
below)
mA
1.630
0.928
0.930
0.928
0.516
0.403
0.400
0.400
0.328
0.237
0.233
0.149
0.190
0.226
0.154
0.188
0.152
0.144
0.120
0.104
1.011
0.842
0.689
0.561
0.459
0.323
0.271
0.223
0.185
0.152
0.126
0.084
0.084
0.084
0.080
0.080
0.065
0.061
0.052
0.048
0.204
0.116
0.116
0.116
0.064
0.050
0.050
0.050
0.041
0.030
0.029
0.019
0.024
0.028
0.019
0.023
0.019
0.018
0.015
0.013
0.183
0.101
0.101
0.101
0.059
0.046
0.046
0.046
0.039
0.027
0.026
0.017
0.022
0.025
0.017
0.021
0.017
0.016
0.014
0.012
690
900
900
900
1240
1500
1500
1500
2000
2459
2530
3350
2930
3000
3600
3200
3600
4247
4300
5327
966
1260
1260
1260
1736
2100
2100
2100
2800
3442
3542
4690
4102
4200
5040
4480
5040
5946
6020
7458
B41888C7157M***
B41888C7187M***
B41888C7227M***
B41888C7277M***
B41888C7337M***
B41888C7477M***
B41888C7567M***
B41888D7687M***
B41888C7827M***
B41888C7108M***
B41888C7128M***
B41888C7188M***
B41888D7188M***
B41888E7188M***
B41888C7228M***
B41888D7228M***
B41888D7278M***
B41888D7338M***
B41888D7398M***
B41888C7478M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm, excluding 12.5 × 40 mm)
002 = for cut leads, bulk (for ∅ ≥ 10 mm, excluding 12.5 × 40 mm)
003 = for crimped leads, blister (from d × l = 16 × 20 mm to 18 × 40 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm, excluding 12.5 × 40 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 10 of 32
B41888
Extended useful life 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
VR = 50 V DC
100
8 × 11.5
120
8 × 11.5
150
10 × 12.5
220
10 × 16
270
10 × 20
330
10 × 20
470
12.5 × 20
560
12.5 × 25
680
12.5 × 25
820
16 × 20
1000
12.5 × 40
1000
16 × 25
1000
18 × 20
1200
16 × 31.5
1200
18 × 25
1500
16 × 31.5
1800
18 × 31.5
2200
18 × 35
2700
18 × 40
ESRmax
10 kHz
40 °C
Ω
ESRmax
120 Hz
20 °C
Ω
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
IAC,max
Ordering code
100 kHz (composition see
85 °C
below)
mA
4.920
4.920
1.824
1.030
0.672
0.672
0.518
0.344
0.344
0.410
0.216
0.283
0.312
0.221
0.275
0.224
0.204
0.177
0.159
1.263
1.053
0.842
0.574
0.468
0.383
0.269
0.226
0.186
0.154
0.126
0.126
0.126
0.105
0.105
0.084
0.070
0.069
0.056
0.615
0.615
0.228
0.129
0.084
0.084
0.065
0.043
0.043
0.051
0.027
0.035
0.039
0.028
0.034
0.028
0.025
0.022
0.020
0.540
0.540
0.203
0.115
0.075
0.075
0.060
0.040
0.040
0.046
0.025
0.032
0.036
0.025
0.031
0.025
0.023
0.020
0.018
500
500
600
1050
1180
1180
1800
2024
2024
1957
2920
2700
2541
3010
2795
3010
3542
3800
4000
700
700
840
1470
1652
1652
2520
2834
2834
2740
4088
3780
3557
4214
3914
4214
4959
5320
5600
B41888C6107M***
B41888C6127M***
B41888D6157M***
B41888C6227M***
B41888C6277M***
B41888C6337M***
B41888C6477M***
B41888C6567M***
B41888C6687M***
B41888C6827M***
B41888C6108M***
B41888D6108M***
B41888G6108M***
B41888C6128M***
B41888D6128M***
B41888C6158M***
B41888C6188M***
B41888C6228M***
B41888C6278M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm, excluding 12.5 × 40 mm)
002 = for cut leads, bulk (for ∅ ≥ 10 mm, excluding 12.5 × 40 mm)
003 = for crimped leads, blister (from d × l = 16 × 20 mm to 18 × 40 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm, excluding 12.5 × 40 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 11 of 32
B41888
Extended useful life 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
VR = 63 V DC
56
8 × 11.5
68
8 × 11.5
82
10 × 12.5
100
10 × 12.5
120
10 × 16
150
10 × 16
180
10 × 20
220
10 × 20
270
12.5 × 20
330
12.5 × 20
390
12.5 × 25
470
16 × 20
560
16 × 20
680
12.5 × 40
680
16 × 25
680
18 × 20
820
16 × 31.5
820
18 × 25
1200
18 × 31.5
1500
18 × 35
1800
18 × 40
ESRmax
10 kHz
40 °C
Ω
ESRmax
120 Hz
20 °C
Ω
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
IAC,max
Ordering code
100 kHz (composition see
85 °C
below)
mA
5.413
4.328
5.766
4.616
3.075
2.464
1.986
1.592
1.688
1.688
1.236
1.037
0.832
0.717
0.772
0.960
0.541
0.761
0.518
0.441
0.375
2.030
1.672
1.386
1.137
0.947
0.758
0.632
0.517
0.421
0.344
0.291
0.242
0.203
0.167
0.167
0.167
0.139
0.139
0.095
0.076
0.063
0.541
0.541
0.577
0.577
0.308
0.308
0.199
0.199
0.169
0.169
0.124
0.104
0.104
0.072
0.077
0.096
0.054
0.076
0.052
0.044
0.038
0.488
0.488
0.500
0.500
0.279
0.279
0.180
0.180
0.153
0.153
0.112
0.094
0.094
0.065
0.070
0.087
0.049
0.069
0.047
0.040
0.034
283
283
323
323
474
474
644
644
800
800
1020
1161
1161
1629
1460
1302
1910
1584
2094
2366
2708
396
396
453
452
664
664
901
902
1120
1120
1428
1625
1625
2281
2045
1823
2674
2217
2932
3313
3792
B41888C8566M***
B41888C8686M***
B41888C8826M***
B41888C8107M***
B41888C8127M***
B41888C8157M***
B41888C8187M***
B41888C8227M***
B41888C8277M***
B41888C8337M***
B41888C8397M***
B41888C8477M***
B41888C8567M***
B41888C8687M***
B41888D8687M***
B41888E8687M***
B41888C8827M***
B41888D8827M***
B41888C8128M***
B41888C8158M***
B41888C8188M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm, excluding 12.5 × 40 mm)
002 = for cut leads, bulk (for ∅ ≥ 10 mm, excluding 12.5 × 40 mm)
003 = for crimped leads, blister (from d × l = 16 × 20 mm to 18 × 40 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm, excluding 12.5 × 40 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 12 of 32
B41888
Extended useful life 105 °C
Useful life
depending on ambient temperature TA under ripple current operating conditions1)
d = 8 mm
d = 10 mm
1) Refer to chapter "General technical information, 5.3 Calculation of useful life" for an explanation on how to interpret the useful life
graphs.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 13 of 32
B41888
Extended useful life 105 °C
Useful life
depending on ambient temperature TA under ripple current operating conditions2)
d = ≥ 12.5 mm
Frequency factor of permissible ripple current IAC versus frequency f
2) Refer to chapter "General technical information, 5.3 Calculation of useful life" for an explanation on how to interpret the useful life
graphs.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 14 of 32
B41888
Extended useful life 105 °C
Taping, packing and lead configurations
Taping
Single-ended capacitors are available taped in Ammo pack from diameter 5 to 18 mm as follows:
Lead spacing F = 2.5 mm (∅ d = 5 … 6.3 mm)
Lead spacing F = 3.5 mm (∅ d = 8 mm)
Lead spacing F = 5.0 mm (from d × l = 10 × 12.5 mm to 12.5 × 30 mm)
Lead spacing F = 7.5 mm (∅ d = 16 ... 18 mm).
Lead spacing 2.5 mm (∅ d = 5 ... 6.3 mm)
Last 3 digits of ordering code: 007
Dimensions in mm
∅d
5
F
H
W
W0
W1
W2
H0
P
P0
P1
I1
t
∆h
D0
2.5 18.5 18.0 5.5 9.0 1.5 16.0 12.7 12.7 5.1 1.0 0.7 1.0 4.0
6.3
Toler- +0.8
±0.75 ±0.5 min. ±0.5 max. ±0.5 ±1.0 ±0.2 ±0.5 max. ±0.2 max. ±0.2
ance 0.2
Please read Cautions and warnings and
Important notes at the end of this document.
Page 15 of 32
B41888
Extended useful life 105 °C
Lead spacing 3.5 mm (∅ d = 8 mm)
Last 3 digits of ordering code: 006
Dimensions in mm
∅d
8
Tolerance
F
H
W
W0
W1
W2
P
P0
P1
I1
t
∆h
3.5
18.5
18.0
12.5
9.0
1.5
12.7
12.7
4.6
1.0
0.7
1.0
+0.8
±1.0
0.2
±0.5
min.
±0.5
max. ±1.0
±0.2
±0.5
max. ±0.2
Please read Cautions and warnings and
Important notes at the end of this document.
Page 16 of 32
D0
4.0
max. ±0.2
B41888
Extended useful life 105 °C
Lead spacing 5.0 mm (∅ d = 5 ... 8 mm)
Last 3 digits of ordering code: 008
Lead spacing 5.0 mm (from d × l = 10 × 12.5 mm to 12.5 × 30 mm)
Last 3 digits of ordering code: 008
Dimensions in mm
∅d
5
6.3
F
H
W
W0
W1
W2
H0
P
P0
P1
I1
t
∆h
D0
5.0
18.5
18.0 5.5
9.0
1.5
16.0
12.7
12.7
3.85
1.0
0.7
1.0
4.0
16.0
12.7
12.7
3.85
18.0 12.5 9.0
1.5
12.7
12.7
3.85
1.0
0.7
1.0
4.0
15.0
15.0
5.0
±1.0
±0.2
±0.5
8
10
20.0
5.0
19.0
12.5
19.0
Toler- +0.8
±0.75 ±0.5 min. ±0.5 max. ±0.5
ance 0.2
Please read Cautions and warnings and
Important notes at the end of this document.
Page 17 of 32
max. ±0.2 max. ±0.2
B41888
Extended useful life 105 °C
Lead spacing 7.5 mm (∅ d = 16 ...18 mm)
Last 3 digits of ordering code: 009
Dimensions in mm
∅d
16
F
H
W
7.5 18.5 18.0
18 *)
Toler0.5
±0.8
±0.5
ance
+0.75
W0
W1
W2
P
P0
P1
I1
t
∆P
∆h
D0
12.5
9.0
1.5
30.0
15.0
3.75
1.0
0.7
0
0
4.0
min.
±0.5
max. ±1.0
±0.2
±0.5
max. ±0.2 ±1.0 ±1.0 ±0.2
*) Available only for case dimensions 18 × 20, 18 × 25 and 18 × 31.5 mm
Please read Cautions and warnings and
Important notes at the end of this document.
Page 18 of 32
B41888
Extended useful life 105 °C
Packing units and box dimensions
Ammo pack
Please read Cautions and warnings and
Important notes at the end of this document.
Case size
d×l
mm
Dimensions (mm)
Amax
Bmax
Cmax
5 × 11
345
55
240
2000
6.3 × 11
345
55
290
2000
8 × 11.5
345
55
240
1000
10 × 12.5
345
55
280
750
10 × 16
345
60
200
500
10 × 20
345
60
200
500
12.5 × 20
345
65
280
500
12.5 × 25
345
65
280
500
16 × 20
315
65
275
300
16 × 25
315
65
275
300
16 × 31.5
315
65
275
300
18 × 20
315
65
275
250
18 × 25
315
65
275
250
18 × 31.5
315
65
275
250
Page 19 of 32
Packing
units
pcs.
B41888
Extended useful life 105 °C
Kinked or cut leads
Single-ended capacitors are available with kinked or cut leads. Other lead configurations also
available upon request.
Kinked leads
Last 3 digits of ordering code: 001
With stand-off rubber seal
Case size
d × l (mm)
With flat rubber seal
Please read Cautions and warnings and
Important notes at the end of this document.
Page 20 of 32
Dimensions (mm)
a ±0.5
10 × 20
5.0
12.5 × 20
5.0
12.5 × 25
5.0
16 × 20
7.5
16 × 25
7.5
16 × 31.5
7.5
18 × 20
7.5
18 × 25
7.5
18 × 31.5
7.5
18 × 35
7.5
18 × 40
7.5
B41888
Extended useful life 105 °C
Cut leads
Last 3 digits of ordering code: 002
With stand-off rubber seal
Case size
d × l (mm)
With flat rubber seal
Please read Cautions and warnings and
Important notes at the end of this document.
Page 21 of 32
Dimensions (mm)
a ±0.5
10 × 12.5
5.0
10 × 16
5.0
10 × 20
5.0
12.5 × 20
5.0
12.5 × 25
5.0
16 × 20
7.5
16 × 25
7.5
16 × 31.5
7.5
18 × 20
7.5
18 × 25
7.5
18 × 31.5
7.5
18 × 35
7.5
18 × 40
7.5
20 × 20
10.0
20 × 25
10.0
20 × 30
10.0
20 × 35
10.0
20 × 40
10.0
22 × 30
10.0
22 × 35
10.0
22 × 40
10.0
B41888
Extended useful life 105 °C
PAPR leads (Protection Against Polarity Reversal)
These lead configurations ensure correct placement of the capacitor on the PCB with regard to
polarity. PAPR leads are available for diameters from 10 mm up to 20 mm.
There are three configurations available: Crimped leads, J leads, bent 90° leads
Crimped leads
Last 3 digits of ordering code: 003
With stand-off rubber seal
With flat rubber seal
Suggestion for PCB hole diameter
Case size
d × l (mm)
Dimensions (mm)
B ±0.2
C ±0.5
D ±0.1
E ±0.1
16 × 20
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
16 × 25
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
16 × 31.5
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
18 × 20
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 25
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 31.5
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 35
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 40
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
20 × 20
1.5
3.0
1.6
0.3
10.0
1.0 ±0.1
20 × 25
1.5
3.0
1.6
0.3
10.0
1.0 ±0.1
20 × 30
1.5
3.0
1.6
0.3
10.0
1.0 ±0.1
20 × 35
1.5
3.0
1.6
0.3
10.0
1.0 ±0.1
20 × 40
1.5
3.0
1.6
0.3
10.0
1.0 ±0.1
Please read Cautions and warnings and
Important notes at the end of this document.
Page 22 of 32
a ±0.5
∅b
B41888
Extended useful life 105 °C
J leads
Last 3 digits of ordering code: 004
Suggestion for PCB hole diameter
Case size
d × l (mm)
Dimensions (mm)
C ±0.5
E ±0.5
J ±0.2
10 × 12.5
3.2
0.7
1.2
5.0
0.6 ±0.05
10 × 16
3.2
0.7
1.2
5.0
0.6 ±0.05
10 × 20
3.2
0.7
1.2
5.0
0.6 ±0.05
12.5 × 20
3.2
0.7
1.2
5.0
0.6 ±0.05
12.5 × 25
3.2
0.7
1.2
5.0
0.6 ±0.05
16 × 20
3.5
0.7
1.6
7.5
0.8 ±0.05
16 × 25
3.5
0.7
1.6
7.5
0.8 ±0.05
16 × 31.5
3.5
0.7
1.6
7.5
0.8 ±0.05
18 × 20
3.5
0.7
1.6
7.5
0.8 ±0.1
18 × 25
3.5
0.7
1.6
7.5
0.8 ±0.1
18 × 31.5
3.5
0.7
1.6
7.5
0.8 ±0.1
18 × 35
3.5
0.7
1.6
7.5
0.8 ±0.1
Please read Cautions and warnings and
Important notes at the end of this document.
Page 23 of 32
a ±0.5
∅b
B41888
Extended useful life 105 °C
Bent 90° leads for horizontal mounting pinning
Last 3 digits of ordering code: 012
Case size
d × l (mm)
Dimensions (mm)
C ±0.5
E ±0.5
F ±0.5
a ±0.5
∅b
16 × 20
4.0
4.0
12.0
7.5
0.8 ±0.05
16 × 25
4.0
4.0
12.0
7.5
0.8 ±0.05
16 × 31.5
4.0
4.0
12.0
7.5
0.8 ±0.05
18 × 20
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 25
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 31.5
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 35
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 40
4.0
4.0
13.0
7.5
0.8 ±0.1
Bent leads for diameter 12.5 mm available upon request.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 24 of 32
B41888
Extended useful life 105 °C
Overview of packing units and code numbers for case sizes 5 × 11 ... 16 × 31.5
PAPR
Case size
d×l
Taped,
Ammo pack
mm
Standard,
bulk
pcs.
pcs.
Kinked
leads,
bulk
pcs.
Cut
leads,
bulk
pcs.
Crimped J leads,
leads,
blister
blister
pcs.
pcs.
2000
5 × 11
2000
6.3 × 11
2500
2000
8 × 11.5
1000
1000
10 × 12.5
1000
750
10 × 16
1000
500
1000
10 × 20
500
500
500
500
12.5 × 20
350
500
350
350
12.5 × 25
250
500
500
500
12.5 × 30
200
12.5 × 35
175
12.5 × 40
175
16 × 20
250
300
200
200
200
200
120
16 × 25
250
300
200
200
200
200
120
16 × 31.5
200
300
250
250
344
344
120
The last three
digits of the
complete
ordering code
state the lead
configuration
000
Code
006
007
008
009
001
002
003
004
012
F (mm) d (mm)
3.5
2.5
5
7.5
8
5...6.3
5...12.5
16...18
1) Available upon request
Please read Cautions and warnings and
Important notes at the end of this document.
Page 25 of 32
1000
Bent 90°
leads,
blister
pcs.
675
675
500
300
1)
225
1)
B41888
Extended useful life 105 °C
Overview of packing units and code numbers for case sizes 18 × 20 ... 25 × 40
PAPR
Case size
d×l
Taped,
Ammo pack
mm
Standard,
bulk
pcs.
pcs.
Kinked
leads,
bulk
pcs.
Cut
leads,
bulk
pcs.
Crimped J leads,
leads,
blister
blister
pcs.
pcs.
Bent 90°
leads,
blister
pcs.
18 × 20
175
18 × 25
150
250
175
175
200
200
120
250
150
150
200
200
18 × 31.5
120
100
250
100
100
150
150
120
18 × 35
100
100
100
150
150
150
18 × 40
125
100
100
120
72
20 × 20
125
125
200
20 × 25
125
125
200
20 × 30
100
100
120
20 × 35
100
100
120
20 × 40
100
100
120
22 × 30
80
100
22 × 35
80
22 × 40
80
25 × 40
40
The last three
digits of the
complete
ordering code
state the lead
configuration
000
Code
007
008
009
Please read Cautions and warnings and
Important notes at the end of this document.
F (mm) d (mm)
2.5
5
7.5
100
100
001
002
4...6.3
6.3...12.5
16...18
Page 26 of 32
003
004
012
B41888
Extended useful life 105 °C
Cautions and warnings
Personal safety
The electrolytes used by EPCOS have not only been optimized with a view to the intended
application, but also with regard to health and environmental compatibility. They do not contain
any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide
(DMAC).
Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They
contain flame-retarding substances which will quickly extinguish any flame that may have been
ignited.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce
operating electrolytes. However, in exceptional cases, such materials must be used in order to
achieve specific physical and electrical properties because no safe substitute materials are
currently known. However, the amount of dangerous materials used in our products has been
limited to an absolute minimum. Nevertheless, the following rules should be observed when
handling Al electrolytic capacitors:
Any escaping electrolyte should not come into contact with eyes or skin.
If electrolyte does come into contact with the skin, wash the affected parts immediately with
running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If
symptoms persist, seek medical treatment.
Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be
well ventilated. Clothing that has been contaminated by electrolyte must be changed and
rinsed in water.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 27 of 32
B41888
Extended useful life 105 °C
Product safety
The table below summarize the safety instructions that must be observed without fail. A detailed
description can be found in the relevant sections of chapter "General technical information".
Topic
Safety information
Polarity
Make sure that polar capacitors are connected
with the right polarity.
Reverse voltage
Voltages polarity classes should be prevented by
connecting a diode.
Do not exceed the upper category temperatur.
Upper category
temperature
Maintenance
Mounting
position of screw
terminal capacitors
Mounting of
single-ended
capacitors
Robustness of
terminals
Soldering
Make periodic inspections of the capacitors.
Before the inspection, make sure that the power
supply is turned off and carefully discharge the
electricity of the capacitors.
Do not apply any mechanical stress to the
capacitor terminals.
Do not mount the capacitor with the terminals
(safety vent) upside down.
Reference
Chapter "General
technical information"
1
"Basic construction of
aluminum electrolytic
capacitors"
3.1.6
"Reverse voltage"
7.2
"Maximum permissible
operating temperature"
10
"Maintenance"
11.1
"Mounting positions of
capacitors with screw
terminals"
The internal structure of single-ended capacitors 11.4
might be damaged if excessive force is applied to "Mounting
the lead wires.
considerations for
Avoid any compressive, tensile or flexural stress. single-ended capacitors"
Do not move the capacitor after soldering to PC
board.
Do not pick up the PC board by the soldered
capacitor.
Do not insert the capacitor on the PC board with a
hole space different to the lead space specified.
The following maximum tightening torques must
11.3
not be exceeded when connecting screw
"Mounting torques"
terminals:
M5: 2 Nm
M6: 2.5 Nm
Do not exceed the specified time or temperature 11.5
limits during soldering.
"Soldering"
Please read Cautions and warnings and
Important notes at the end of this document.
Page 28 of 32
B41888
Extended useful life 105 °C
Topic
Soldering,
cleaning agents
Passive
flammability
Active
flammability
Safety information
Reference
Chapter "General
technical information"
Do not allow halogenated hydrocarbons to come 11.6
into contact with aluminum electrolytic capacitors. "Cleaning agents"
Avoid external energy, such as fire or electricity.
8.1
"Passive flammability"
Avoid overload of the capacitors.
8.2
"Active flammability"
Breakdown strength Do not damage the insulating sleeve, especially
of insulating
when ring clips are used for mounting.
sleeves
Please read Cautions and warnings and
Important notes at the end of this document.
Page 29 of 32
Reference
Chapter "Capacitors
with screw terminals"
"Screw terminals accessories"
B41888
Extended useful life 105 °C
Symbols and terms
Symbol
English
German
C
CR
CS
CS,T
Cf
d
dmax
ESL
ESR
ESRf
Capacitance
Rated capacitance
Series capacitance
Series capacitance at temperature T
Capacitance at frequency f
Case diameter, nominal dimension
Maximum case diameter
Self-inductance
Equivalent series resistance
Equivalent series resistance at
frequency f
Equivalent series resistance at
temperature T
Frequency
Current
Alternating current (ripple current)
Root-mean-square value of alternating
current
Ripple current at frequency f
Maximum permissible ripple current
Rated ripple current
Rated ripple current for base cooling
Leakage current
Operating leakage current
Case length, nominal dimension
Maximum case length (without
terminals and mounting stud)
Resistance
Insulation resistance
Balancing resistance
Temperature
Temperature difference
Ambient temperature
Case temperature
Capacitor base temperature
Time
Period
Service life (operating hours)
Kapazität
Nennkapazität
Serienkapazität
Serienkapazität bei Temperatur T
Kapazität bei Frequenz f
Gehäusedurchmesser, Nennmaß
Maximaler Gehäusedurchmesser
Eigeninduktivität
Ersatzserienwiderstand
Ersatzserienwiderstand bei Frequenz f
ESRT
f
I
IAC
IAC,rms
IAC,f
IAC,max
IAC,R
IAC,R (B)
Ileak
Ileak,op
l
lmax
R
Rins
Rsymm
T
∆T
TA
TC
TB
t
∆t
tb
Please read Cautions and warnings and
Important notes at the end of this document.
Ersatzserienwiderstand bei Temperatur T
Frequenz
Strom
Wechselstrom
Wechselstrom, Effektivwert
Wechselstrom bei Frequenz f
Maximal zulässiger Wechselstrom
Nennwechselstrom
Nennwechselstromstrom für Bodenkühlung
Ableitstrom
Ableitstrom bei Betrieb
Gehäuselänge, Nennmaß
Maximale Gehäuselänge (ohne Anschlüsse
und Gewindebolzen)
Widerstand
Isolationswiderstand
Symmetrierwiderstand
Temperatur
Temperaturdifferenz
Umgebungstemperatur
Gehäusetemperatur
Temperatur des Becherbodens
Zeit
Zeitraum
Brauchbarkeitsdauer (Betriebszeit)
Page 30 of 32
B41888
Extended useful life 105 °C
Symbol
V
VF
Vop
VR
VS
XC
XL
Z
ZT
tan δ
λ
ε0
εr
ω
English
Voltage
Forming voltage
Operating voltage
Rated voltage, DC voltage
Surge voltage
Capacitive reactance
Inductive reactance
Impedance
Impedance at temperature T
Dissipation factor
Failure rate
Absolute permittivity
Relative permittivity
Angular velocity; 2 π f
German
Spannung
Formierspannung
Betriebsspannung
Nennspannung, Gleichspannung
Spitzenspannung
Kapazitiver Blindwiderstand
Induktiver Blindwiderstand
Scheinwiderstand
Scheinwiderstand bei Temperatur T
Verlustfaktor
Ausfallrate
Elektrische Feldkonstante
Dielektrizitätszahl
Kreisfrequenz; 2 π f
Notes
All dimensions are given in mm.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 31 of 32
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, CTVS, DSSP, MiniBlue, MKK,
MLSC, MotorCap, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap,
SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks
registered or pending in Europe and in other countries. Further information will be found on
the Internet at www.epcos.com/trademarks.
Page 32 of 32
Similar pages