Crydom D53TP50D Panel mount Datasheet

53TP Series IP00
• Three-phase solid-state relay; Ratings 25A, 50A per phase @ 48-530 VAC
• 2 package styles IP00 or IP20 (See IP20 spec sheet for more information)
• SCR output for heavy industrial loads
• Transient protection built in
• AC or DC control
• Zero-crossing (resistive loads) or random-fire (inductive loads) output
• LED input status indicator
• UL Recognized, CE Compliant to EN60950-1
PRODUCT SELECTION
Control Voltage
90-280 VAC
4-32 VDC
25A
50A
A53TP25D
D53TP25D
A53TP50D
D53TP50D
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk] (2)
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3)
Maximum Load Current [Arms] (4)
Minimum Load Current [Arms]
Maximum Surge Current 50-60 Hz (16.6ms) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum I²t for Fusing 50-60 Hz (8.3 msec) [A² sec]
Minimum Power Factor (with Maximum Load)
25 A
50 A
48-530
1200
10
500
25
0.05
239/250
1.6
1.02
285/260
0.5
48-530
1200
10
500
50
0.05
597/625
1.6
0.63
1779/1620
0.5
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Minimum Turn-On Voltage
Minimum Turn-Off Voltage
Minimum Input Current (for on-state)
Maximum Input Current
Nominal Input Impedance
Maximum Turn-On Time [msec] (5)
Maximum Turn-Off Time [msec]
D53
A53
4-32 VDC
4.0 VDC
1.0 VDC
19 mA @ 4V
25 mA @ 32V
Current Limiter
1/2 Cycle
1/2 Cycle
90-280 Vrms
90 Vrms
10 Vrms
2.2 mA @ 120V
10mA @ 240V
Current Limiter
50
50
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 V DC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Encapsulation
Terminals
Screws and Saddle clamps
Input Terminal Screw Torque Range:[in lbs/Nm]
Output Terminal Screw Torque Range:[in lbs/Nm]
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Relay will self trigger between 900-1200 Vpk.
3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
4) Heat sinking required, see page 4 for derating curves.
5) Turn-on time for Random turn-on versions is 0.02 msec (DC Control Models)
Parameters
4000 Vrms
109 Ohm
8 pF
-40 to 80°C
-40 to 125 °C
10.3 oz (315g)
Thermally conductive Epoxy
Nickel plated Brass
Zinc plated Steel
8-10 / 0.9-1.1
15-20 / 1.7-2.2
MECHANICAL SPECIFICATIONS
WIRING DIAGRAM
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Input :
EN61000-4-2, Level 3 ESD
EN61000-4-4, Level 3 Burst
Output :
EN61000-4-2, Level 4 ESD
EN61000-4-4, Level 4 Burst
EN61000-4-5, Level 4 Surge
EN60950 : Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7:
Rev. 120811
ANNEX - ENVIROMENTAL INFORMATION