AIMTEC AME10-3.3SCJZ 10 watt | ac-dc / dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AME10-CJZ
10 Watt | AC-DC / DC-DC Converter
FEATURES:
•
•
•
•
I/O Isolation 3000VAC
Operating Temp: -25 °C to +70 °C
Input: 85-264VAC, 47-63Hz, or 120-370VDC
Over current, Over Voltage Protection
•
•
•
•
Continuous Short circuit protection
Energy Star compliant
Compact package
Efficiency up to 84%
Models
Single output
Model
AME10-3.3SCJZ
AME10-5SCJZ
AME10-9SCJZ
AME10-12SCJZ
AME10-15SCJZ
AME10-24SCJZ
Input Voltage
(VAC/Hz)
Input Voltage
(VDC)
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
120-370
120-370
120-370
120-370
120-370
120-370
Input Voltage
(VAC/Hz)
Input Voltage
(VDC)
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
120-370
120-370
120-370
120-370
Output
Voltage
(V)
3.3
5
9
12
15
24
Output
Current max
(A)
2
2
1.1
0.9
0.7
0.45
Maximum
capacitive
Load
(µF)
Efficiency
230VAC
(%)
26400
9440
3600
2400
1170
370
70
76
78
80
81
82
Maximum
capacitive
Load
(µF)
Efficiency
230VAC
(%)
±8800
±1970
±1970
±660
76
80
81
84
Models
Dual output
Model
AME10-5DCJZ
AME10-12DCJZ
AME10-15DCJZ
AME10-24DCJZ
Output
Voltage
(V)
±5
±12
±15
±24
Output
Current max
(A)
±1
±0.45
±0.35
±0.2
Models
Triple output
Model
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Output
Voltage
(V)
Auxiliary
Output
Voltage
(V)
Output
Current max
(A)
Maximum
capacitive
Load
(µF)
Efficiency
230VAC
(%)
AME10-512TCJZ
AME10-515TCJZ
85-264/47-63
85-264/47-63
120-370
120-370
5
5
±12
±15
1/±0.2
0.9/±0.2
3200/±260
2160/±80
75
75
Models
Asymmetric Separated Dual output
Model
AME10-505DCJZ
AME10-512DCJZ
AME10-515DCJZ
AME10-524DCJZ
AME10-1224DCJZ
Input Voltage
(VAC/Hz)
Input Voltage
(VDC)
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
120-370
120-370
120-370
120-370
120-370
Output
Voltage
(V)
5/5
5/12
5/15
5/24
12/24
Output
Current max
(A)
1.8/0.2
1.5/0.2
1.4/0.2
1/0.2
0.42/0.2
Maximum
capacitive
Load
(µF)
Efficiency
230VAC
(%)
8000/540
4400/260
4400/170
4000/170
1100/170
75
79
79
81
80
Note: Add suffix “-ST” for optional screw terminal bottom plate or “-STD” for optional DIN Rail screw terminal bottom plate.
www.aimtec.com
F 052e R8. D
Tel: +1 514 620 2722
1 of 7
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME10-CJZ
10 Watt | AC-DC / DC-DC Converter
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Conditions
Typical
115 VAC
230 VAC
115 VAC
230 VAC
230VAC/50Hz
Recommended slow blow type


10
20

2
Maximum
260
160
Units
mA
mA
A
A
mA
A
0.3
Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
Line regulation
Load regulation (single output)
Load Regulation (dual output)
Load Regulation (triple &
asymmetric separated output)
Minimum load
Full load, main output
Full load, auxiliary output
10-100% load
10-100% Balanced load
10-100% Balanced load, main output
10-100% Balanced load, auxiliary output
Single output
Others
Ripple & Noise *
115VAC, 20MHz bandwidth
230VAC, 20MHz bandwidth
Hold-up time
Maximum
±2
±0.5
±1.5
±1
±2
±3
±5
0
10
50
15
80
Units
%
%
%
%
%
150
%
%
mV p-p
ms
ms
Rated
Units
3000
500
VAC
VDC
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Isolation voltage between Main and Auxiliary
output
Isolation Resistance
Typical
60 sec
60 sec
MΩ
>1000
General Specifications
Parameters
Switching frequency
Protection class
Over current protection
Over voltage protection
Short circuit protection
Operating temperature
Storage temperature
Maximum Case temperature
Temperature coefficient
Cooling
Humidity
Case material
Weight
Conditions
Typical
100% load
65
Class I
≥110
Zener diode clamp
Continuous, Auto recovery
-25 to +70
-25 to +105
See derating curve
Maximum
KHz
% of Iout
oC
oC
100
±0.02
Units
oC
% / oC
Free air convection
Non condensing
95
% RH
Plastic (flammability to UL 94V-0)
PCB mountable model:
80
With optional -ST mounting plate:
130
g
With optional -STD mounting plate:
170
Dimensions (L x W x H)
PCB mountable model:
2.165 x 1.772 x 0.827 inches (55.00 x 45.00 x 21.00mm)
With optional -ST mounting plate:
3.783 x 2.126 x 1.161 inches (96.10 x 54.00 x 29.50 mm)
With optional -STD mounting plate:
3.783 x 2.126 x 1.343 inches (96.10 x 54.00 x 34.10 mm)
MTBF
> 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
www.aimtec.com
F 052e R8. D
Tel: +1 514 620 2722
2 of 7
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME10-CJZ
10 Watt | AC-DC / DC-DC Converter
Safety Specifications
Parameters
Agency approvals
Standards
cULus (except triple output models and AME10-1224DCJZ), CE
Information technology Equipment
IEC/EN/UL 60950-1
EMI - Conducted and radiated emission
EN55022, class B
Electrostatic Discharge Immunity
IEC 61000-4-2 Level 3
RF, Electromagnetic Field Immunity
IEC 61000-4-3 Level 3
Electrical Fast Transient/Burst Immunity
IEC 61000-4-4 Level 3
Surge Immunity
IEC 61000-4-5 Level 3
RF, Conducted Disturbance Immunity
IEC 61000-4-6 Level 3
Power frequency Magnetic Field Immunity
IEC 61000-4-8 Level 3
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11 Class 2
Dimensions
3
2
Bottom
View
8
7
6
5
4
1
Top View
2
6
7
8
3
1
4.00
(0.16)
4
5
5.00
(0.20)
17.50
(0.69)
45.00
(1.77)
12.50
(0.49)
5.00
(0.20)
55.00
(2.17)
47.00
(1.85)
4.00
(0.16)
DIV: 10.00 (0.40)
21.00
(0.83)
Ø 1.50 (Ø 0.06)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004)
6.00
(0.24)
1.00
(0.04)
Pin Out Specifications
Pin
Single
Dual
Triple
Asymmetric Dual
1
2
3
4
5
6
7
8
Ground
AC Input (N)
AC Input (L)
-V Output
No pin
No pin
No pin
+V Output
Ground
AC Input (N)
AC Input (L)
-V Output
No pin
Common
No pin
+V Output
Ground
AC Input (N)
AC Input (L)
-V Output 1
+V Output 1
-V Output 2
Common
+V Output 2
Ground
AC Input (N)
AC Input (L)
-V Output 1
+V Output 1
No pin
-V Output 2
+V Output 2
www.aimtec.com
F 052e R8. D
Tel: +1 514 620 2722
3 of 7
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME10-CJZ
10 Watt | AC-DC / DC-DC Converter
With optional -ST bottom plate
96.10
(3.78)
86.10
(3.39)
Ø 3.50
(0.14)
4
46.00
(1.81)
54.00
(2.13)
1
5
2
Top view
3
6
7
8
MST
8.50
(0.34)
20.60
(0.81)
Side view
29.50
(1.16)
Dimensions: mm (inch)
Case Tolerance:± 0.50 (0.02)
Wire gauge: 24-12AWG
www.aimtec.com
F 052e R8. D
Tel: +1 514 620 2722
4 of 7
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME10-CJZ
10 Watt | AC-DC / DC-DC Converter
With optional -STD bottom plate
96.10
(3.78)
86.10
(3.39)
4
46.00
(1.81)
54.00
(2.13)
1
5
2
6
Top view
3
7
8
MST
25.20
(0.99)
Side view
34.10
(1.34)
8.50
(0.34)
Dimensions: mm (inch)
Case Tolerance:± 0.50 (0.02)
Wire gauge: 24-12AWG
Derating
Free Air Convection at 25°C
100
100
80
Output Power (%)
Output power (%)
Free Air Convection
Safe Operating Area
70
Input 100-240VAC or
120-340VDC
60
40
20
80
75
60
Safe Operating Area
40
20
0
- 25
-20
-10
55
0
20
40
60
70
80
Ambient Temperature º C
www.aimtec.com
F 052e R8. D
100
0
85
100
(100) (120)
240
(320)
264
(350)
Input Voltage VAC (VDC)
Tel: +1 514 620 2722
5 of 7
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME10-CJZ
10 Watt | AC-DC / DC-DC Converter
Typical application circuits
FUSE
2A/300V
Single Output
NTC
+ Vout
AC L
AC L
MOV
S14K350
AC N
AC
+ Vout
C1
C2
1µF/50V
AC N
Earth/GND
FUSE
2A/300V
- Vout
- Vout
Dual Output
NTC
+ Vout
AC L
AC L
MOV
S14K350
AC N
AC
Com
DC
Earth/GND
TVS 1
C4
+
Com
TVS 2
- Vout
+
Vout 1
AC N
+ Vout
+
- Vout
AC L
MOV
S14K350
C2
Asymmetric
Dual Output
NTC
AC L
C1
1µF/50V
C3
1µF/50V
AC N
FUSE
2A/300V
TVS
+
DC
C1
1µF/50V
DC +
AC
AC N
Earth/GND
Vout 2
C3
1µF/50V
C2
+ Vout 1
+
TVS 1
C4
- Vout 1
+ Vout 2
+
TVS 2
-
FUSE
2A/300V
Triple Output
NTC
+
AC L
AC L
- Vout 2
Vout 1
MOV
S14K350
AC N
C1
1µF/50V
TVS1
AC N
AC
Earth/GND
+ Vout 2
DC
Vout 1
-
C5
1µF/50V
Com
- Vout 2
F 052e R8. D
+
+
-
C3
1µF/50V
www.aimtec.com
C2
Tel: +1 514 620 2722
6 of 7
C6
+ Vout 2
+
TVS2
C4
+
Com
TVS3
- Vout 2
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME10-CJZ
10 Watt | AC-DC / DC-DC Converter
Model
Single 3.3 Vout
Single 5 Vout
Single 9 Vout
Single 12 & 15 Vout
Single 24 Vout
Dual ±5 Vout
Dual ±12 Vout
Dual ±15 Vout
Dual ±24 Vout
Triple 5/±12 Vout
Triple 5/±15 Vout
Dual 5/5 Vout
Dual 5/12 Vout
Dual 5/15 Vout
Dual 5/24 Vout
C2
470 µF
330 µF
120 µF
120 µF
68 µF
220 µF
120 µF
47 µF
33 µF
220 µF
220 µF
220 µF
220 µF
220 µF
220 µF
C4
220 µF
120 µF
47 µF
33 µF
68 µF
47 µF
68 µF
68 µF
47 µF
47 µF
C6
68 µF
47 µF
-
TVS1
7V
7V
12V
20V
30V
7V
20V
20V
30V
7V
7V
7V
7V
7V
7V
TVS2
7V
20V
20V
30V
20V
20V
7V
20V
20V
30V
TVS3
20V
20V
-
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8. D
Tel: +1 514 620 2722
7 of 7
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Similar pages