Dallas DS1818-20 3.3v econoreset with pushbutton Datasheet

DS1818
3.3V EconoReset with Pushbutton
www.dalsemi.com
FEATURES
PIN ASSIGNMENT
Automatically restarts a microprocessor after
power failure
Monitors pushbutton for external override
Maintains reset for 150 ms after VCC returns
to an in-tolerance condition
Reduces need for discrete components
Precision temperature-compensated voltage
reference and voltage sensor
Accurate 5%, 10% or 20% power monitoring
Low-cost TO-92 or space saving surface
mount SOT-23 packages available
Efficient open-drain output with internal
5.5 kΩ=pull-up resistor
Operating temperature -40°C to +85°C
3
1
2
SOT-23 PACKAGE
1 2 3
1 2 3
TO-92 PACKAGE
See Mech.
Drawings Section
PIN DESCRIPTION
TO-92
1
2
3
RST
VCC
GND
Active Low Reset Output
Power Supply
Ground
SOT-23
1
2
3
RST
VCC
GND
Active Low Reset Output
Power Supply
Ground
DESCRIPTION
The DS1818 EconoReset uses a precision temperature-compensated reference and comparator circuit to
monitor the status of the power supply (VCC). When an out-of-tolerance condition is detected, an internal
power-fail signal is generated which forces reset to the active state. When VCC returns to an in-tolerance
condition, the reset signal is kept in the active state for approximately 150 ms to allow the power supply
and processor to stabilize.
The DS1818 also monitors a pushbutton on the reset output. If the reset line is pulled low, a reset is
generated upon release and the DS1818 output will be held in reset output low for typically 150 ms.
1 of 5
111999
DS1818
OPERATION - POWER MONITOR
The DS1818 provides the functions of detecting out-of-tolerance power supply conditions and warning a
processor-based system of impending power failures. When VCC is detected as out-of-tolerance, the RST
signal is asserted. On power-up, RST is kept active for approximately 150 ms after the power supply has
reached the selected tolerance. This allows the power supply and microprocessor to stabilize before RST
is released.
BLOCK DIAGRAM (OPEN-DRAIN OUTPUT) Figure 1
APPLICATION EXAMPLE Figure 2
OPERATION - PUSHBUTTON RESET
The DS1818 provides a pushbutton switch for manual reset control. When the DS1818 is not in a reset
cycle, a pushbutton reset can be generated by pulling the RST pin low for at least 1 µs. When the
pushbutton is held low, the RST is forced active low and will remain active low for about 150 ms after
the pushbutton is released. See Figure 2 for an application example and Figure 3 for the timing diagram.
TIMING DIAGRAM: PUSHBUTTON RESET Figure 3
2 of 5
DS1818
TIMING DIAGRAM: POWER-UP Figure 4
TIMING DIAGRAM: POWER-DOWN Figure 5
3 of 5
DS1818
ABSOLUTE MAXIMUM RATINGS*
Voltage on VCC Pin Relative to Ground
Voltage on RST Relative to Ground
Operating Temperature
Storage Temperature
Soldering Temperature
*
-0.5V to +7.0V
-0.5V to +5VCC +0.5V
-40°C to +85°C
-55°C to +125°C
260°C for 10 seconds
This is a stress rating only and functional operation of the device at these or any other conditions
above those indicated in the operation sections of this specification is not implied. Exposure to
absolute maximum rating conditions for extended periods of time may affect reliability.
RECOMMENDED DC OPERATING CONDITIONS
PARAMETER
Supply Voltage
SYMBOL
VCC
DC ELECTRICAL CHARACTERISTICS
PARAMETER
MIN
1.0
(-40°C to +85°C)
TYP
MAX
5.5
UNITS
V
NOTES
1
(-40°C to +85°C; VCC=1.2V to 5.5V)
SYMBOL
MIN
Output Current @ 0.4 V
IOL
+10
Voltage Input Low
VIL
Voltage Input High
VIH
Operating Current VCC < 5.5V
ICC
TYP
MAX
0.4
0.7
*VCC
UNITS
NOTES
mA
2, 3
V
1
V
1
28
35
µA
4
VCC Trip Point (DS1818-5)
VCCTP
2.98
3.06
3.15
V
1
VCC Trip Point (DS1818-10)
VCCTP
2.80
2.88
2.97
V
1
VCC Trip Point (DS1818-20)
VCCTP
2.47
2.55
2.64
V
1
RP
3.50
5.5
7.5
kΩ
7
10
pF
Internal Pull-up Resistor
Output Capacitance
COUT
AC ELECTRICAL CHARACTERISTICS
PARAMETER
RESET Active Time
VCC Detect to RST
SYMBOL
tRST
(-40°C to +85°C; VCC=1.2V to 5.5V)
MIN
100
tRPD
TYP
150
MAX
250
UNITS
ms
2
5
µs
VCC Slew Rate
(VCCTP (MAX) to VCCTP (MIN))
tF
300
µs
VCC Slew Rate
(VCCTP (MIN) to VCCTP (MAX))
tR
0
ns
VCC Detect to RST
tRPU
100
Pushbutton Detect to RST
tPB
1
tPBRST
100
Pushbutton Reset
4 of 5
150
250
ms
NOTES
5
8
5, 6
µs
150
250
ms
5
DS1818
NOTES:
1. All voltages are referenced to ground.
2. Measured with VCC ≥ 2.7V.
3. A 1 kΩ external pull-up resistor may be required in some applications for proper operation of the
microprocessor reset control circuit.
4. Measured with RST output open.
5. Measured with 2.7V ≤ VCC ≤ 3.3V.
6. tR = 5 µs.
7. VOH and IOH are a function of the value of RP and the associated output load conditions.
8. The tF value is for reference in defining values for tRPD and should not be considered a requirement for
proper operation or use of the device.
PART MARKING CODES
“A”, “B”, &“C” represent the device type.
810
DS1810
811
DS1811
812
DS1812
813
DS1813
815
DS1815
816
DS1816
817
DS1817
818
DS1818
“D” represents the device tolerance.
A
5%
B
10%
C
15%
D
20%
5 of 5
Similar pages