Fairchild MTC16 Synchronous presettable binary counter Datasheet

Revised September 2003
74AC161 • 74ACT161
Synchronous Presettable Binary Counter
General Description
Features
The AC/ACT161 are high-speed synchronous modulo-16
binary counters. They are synchronously presettable for
application in programmable dividers and have two types
of Count Enable inputs plus a Terminal Count output for
versatility in forming synchronous multistage counters. The
AC/ACT161 has an asynchronous Master Reset input that
overrides all other inputs and forces the outputs LOW.
■ ICC reduced by 50%
■ Synchronous counting and loading
■ High-speed synchronous expansion
■ Typical count rate of 125 MHz
■ Outputs source/sink 24 mA
■ ACT161 has TTL-compatible inputs
Ordering Code:
Order Number
74AC161SC
74AC161SJ
74AC161MTC
Package Number
Package Description
M16A
16-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-012, 0.150" Narrow
M16D
16-Lead Small Outline Package (SOP), EIAJ TYPE II, 5.3mm Wide
MTC16
74AC161PC
N16E
16-Lead Thin Shrink Small Outline Package (TSSOP), JEDEC MO-153, 4.4mm Wide
16-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300" Wide
74ACT161SC
M16A
16-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-012, 0.150" Narrow
74ACT161SJ
M16D
16-Lead Small Outline Package (SOP), EIAJ TYPE II, 5.3mm Wide
74ACT161MTC
MTC16
74ACT161PC
N16E
16-Lead Thin Shrink Small Outline Package (TSSOP), JEDEC MO-153, 4.4mm Wide
16-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300" Wide
Device also available in Tape and Reel. Specify by appending suffix letter “X” to the ordering code.
Connection Diagram
Logic Symbols
IEEE/IEC
Pin Descriptions
Pin Names
CEP
Description
Count Enable Parallel Input
CET
Count Enable Trickle Input
CP
Clock Pulse Input
MR
Asynchronous Master Reset Input
P0–P3
Parallel Data Inputs
PE
Parallel Enable Inputs
Q0–Q3
Flip-Flop Outputs
TC
Terminal Count Output
FACT is a trademark of Fairchild Semiconductor Corporation.
© 2003 Fairchild Semiconductor Corporation
DS009931
www.fairchildsemi.com
74AC161 • 74ACT161 Synchronous Presettable Binary Counter
November 1988
74AC161 • 74ACT161
Functional Description
its the clock period is the CP to TC delay of the first stage
plus the CEP to CP setup time of the last stage. The TC
output is subject to decoding spikes due to internal race
conditions and is therefore not recommended for use as a
clock or asynchronous reset for flip-flops, registers or
counters.
The AC/ACT161 count in modulo-16 binary sequence.
From state 15 (HHHH) they increment to state 0 (LLLL).
The clock inputs of all flip-flops are driven in parallel
through a clock buffer. Thus all changes of the Q outputs
(except due to Master Reset of the AC/ACT161) occur as a
result of, and synchronous with, the LOW-to-HIGH transition of the CP input signal. The circuits have four fundamental modes of operation, in order of precedence:
asynchronous reset, parallel load, count-up and hold. Five
control inputs—Master Reset, Parallel Enable (PE), Count
Enable Parallel (CEP) and Count Enable Trickle (CET)—
determine the mode of operation, as shown in the Mode
Select Table. A LOW signal on MR overrides all other
inputs and asynchronously forces all outputs LOW. A LOW
signal on PE overrides counting and allows information on
the Parallel Data (Pn) inputs to be loaded into the flip-flops
on the next rising edge of CP. With PE and MR HIGH, CEP
and CET permit counting when both are HIGH. Conversely,
a LOW signal on either CEP or CET inhibits counting.
Logic Equations: Count Enable = CEP • CET • PE
TC = Q0 • Q1 • Q2 • Q3 • CET
Mode Select Table
CET
CEP
X
X
X
Reset (Clear)
Load (Pn→Qn)
L
X
X
H
H
Count (Increment)
H
L
X
No Change (Hold)
H
X
L
No Change (Hold)
State Diagram
The Terminal Count (TC) output is HIGH when CET is
HIGH and counter is in state 15. To implement synchronous multistage counters, the TC outputs can be used with
the CEP and CET inputs in two different ways.
Figure 1 shows the connections for simple ripple carry, in
which the clock period must be longer than the CP to TC
delay of the first stage, plus the cumulative CET to TC
delays of the intermediate stages, plus the CET to CP
setup time of the last stage. This total delay plus setup time
sets the upper limit on clock frequency. For faster clock
rates, the carry lookahead connections shown in Figure 2
are recommended. In this scheme the ripple delay through
the intermediate stages commences with the same clock
that causes the first stage to tick over from max to min in
the Up mode, or min to max in the Down mode, to start its
final cycle. Since this final cycle requires 16 clocks to complete, there is plenty of time for the ripple to progress
through the intermediate stages. The critical timing that lim-
FIGURE 1. Multistage Counter with Ripple Carry
FIGURE 2. Multistage Counter with Lookahead Carry
www.fairchildsemi.com
2
Clock Edge (
H
H = HIGH Voltage Level
L = LOW Voltage Level
X = Immaterial
The AC/ACT161 use D-type edge-triggered flip-flops and
changing the PE, CEP, and CET inputs when the CP is in
either state does not cause errors, provided that the recommended setup and hold times, with respect to the rising
edge of CP, are observed.
Action on the Rising
PE
)
74AC161 • 74ACT161
Block Diagram
Please note that this diagram is provided only for the understanding of logic operations and should not be used to estimate propagation delays.
3
www.fairchildsemi.com
74AC161 • 74ACT161
Absolute Maximum Ratings(Note 1)
Supply Voltage (VCC)
Recommended Operating
Conditions
−0.5V to +7.0V
DC Input Diode Current (IIK)
VI = −0.5V
−20 mA
VI = VCC + 0.5V
+20 mA
DC Input Voltage (VI)
Supply Voltage (VCC)
−0.5V to VCC + 0.5V
DC Output Diode Current (IOK)
VO = −0.5V
−20 mA
VO = VCC + 0.5V
+20 mA
DC Output Voltage (VO)
4.5V to 5.5V
0V to VCC
Output Voltage (VO)
0V to VCC
−40°C to +85°C
Operating Temperature (TA)
Minimum Input Edge Rate (∆V/∆t)
−0.5V to VCC + 0.5V
AC Devices
VIN from 30% to 70% of VCC
±50 mA
VCC @ 3.3V, 4.5V, 5.5V
125 mV/ns
Minimum Input Edge Rate (∆V/∆t)
DC VCC or Ground Current
±50 mA
per Output Pin (ICC or IGND)
Storage Temperature (TSTG)
2.0V to 6.0V
ACT
Input Voltage (VI)
DC Output Source
or Sink Current (IO)
AC
ACT Devices
−65°C to +150°C
VIN from 0.8V to 2.0V
Junction Temperature (TJ)
VCC @ 4.5V, 5.5V
140°C
PDIP
125 mV/ns
Note 1: Absolute maximum ratings are those values beyond which damage
to the device may occur. The databook specifications should be met, without exception, to ensure that the system design is reliable over its power
supply, temperature, and output/input loading variables. Fairchild does not
recommend operation of FACT circuits outside databook specifications.
DC Electrical Characteristics for AC
Symbol
VIH
VIL
VOH
Parameter
TA = +25°C
VCC
TA = −40°C to +85°C
(V)
Typ
Guaranteed Limits
Minimum HIGH Level
3.0
1.5
Input Voltage
4.5
2.25
3.15
3.15
5.5
2.75
3.85
3.85
2.1
Units
Maximum LOW Level
3.0
1.5
0.9
0.9
Input Voltage
4.5
2.25
1.35
1.35
5.5
2.75
1.65
1.65
Minimum HIGH Level
3.0
2.99
2.9
2.9
Output Voltage
4.5
4.49
4.4
4.4
5.5
5.49
5.4
5.4
3.0
2.56
2.46
4.5
3.86
3.76
5.5
4.86
4.76
0.1
0.1
Conditions
VOUT = 0.1V
2.1
V
or VCC − 0.1V
VOUT = 0.1V
V
or VCC − 0.1V
V
IOUT = −50 µA
VIN = VIL or VIH
VOL
Maximum LOW Level
3.0
0.002
Output Voltage
4.5
0.001
0.1
0.1
5.5
0.001
0.1
0.1
3.0
0.36
0.44
4.5
0.36
0.44
5.5
0.36
0.44
5.5
±0.1
IOH = −12 mA
V
IOH = −24 mA
IOH = −24 mA (Note 2)
V
IOUT = 50 µA
VIN = VIL or VIH
IIN
Maximum Input
IOL = 12 mA
V
IOL = 24 mA
IOL = 24 mA (Note 2)
(Note 4)
Leakage Current
±1.0
µA
VI = VCC, GND
IOLD
Minimum Dynamic
5.5
75
mA
VOLD = 1.65V Max
IOHD
Output Current (Note 3)
5.5
−75
mA
VOHD = 3.85V Min
ICC
Maximum Quiescent
(Note 4)
Supply Current
40.0
µA
5.5
4.0
Note 2: All outputs loaded; thresholds on input associated with output under test.
Note 3: Maximum test duration 2.0 ms, one output loaded at a time.
Note 4: IIN and ICC @ 3.0V are guaranteed to be less than or equal to the respective limit @ 5.5V VCC.
www.fairchildsemi.com
4
VIN = VCC
or GND
Symbol
Parameter
Minimum HIGH Level
VIH
VIL
VOH
TA = +25°C
VCC
(V)
Typ
4.5
1.5
TA = −40°C to +85°C
Guaranteed Limits
2.0
Units
2.0
Input Voltage
5.5
1.5
2.0
2.0
Maximum LOW Level
4.5
1.5
0.8
0.8
V
V
Conditions
VOUT = 0.1V
or VCC − 0.1V
VOUT = 0.1V
Input Voltage
5.5
1.5
0.8
0.8
or VCC − 0.1V
Minimum HIGH Level
4.5
4.49
4.4
4.4
IOUT = −50 µA
Output Voltage
5.5
5.49
5.4
5.4
3.86
3.76
V
VIN = VIL or VIH
4.5
5.5
VOL
V
IOH = −24 mA
IOH = −24 mA (Note 5)
4.86
4.76
Maximum LOW Level
4.5
0.001
0.1
0.1
Output Voltage
5.5
0.001
0.1
0.1
4.5
0.36
0.44
5.5
0.36
0.44
5.5
±0.1
±1.0
µA
1.5
mA
V
IOUT = 50 µA
VIN = VIL or VIH
IIN
Maximum Input
Leakage Current
ICCT
Maximum
5.5
ICC/Input
0.6
V
IOL = 24 mA
IOL = 24 mA (Note 5)
VI = VCC, GND
VI = VCC − 2.1V
IOLD
Minimum Dynamic
5.5
75
mA
VOLD = 1.65V Max
IOHD
Output Current (Note 6)
5.5
−75
mA
VOHD = 3.85V Min
ICC
Maximum Quiescent
40.0
µA
Supply Current
5.5
4.0
VIN = VCC
or GND
Note 5: All outputs loaded; thresholds on input associated with output under test.
Note 6: Maximum test duration 2.0 ms, one output loaded at a time.
AC Electrical Characteristics for AC
Symbol
Parameter
VCC
TA = +25°C
(V)
CL = 50 pF
(Note 7)
fMAX
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPHL
tPHL
Min
Typ
TA = −40°C to +85°C
CL = 50 pF
Max
Min
Maximum Count
3.3
70
111
60
Frequency
5.0
110
167
95
Units
Max
MHz
Propagation Delay CP to Qn
3.3
2.0
7.0
12
1.5
13.5
(PE Input HIGH or LOW)
5.0
1.5
5.0
9.0
1.0
9.5
Propagation Delay CP to Qn
3.3
1.5
7.0
12
1.5
13
(PE Input HIGH or LOW)
5.0
1.5
5.0
9.5
1.5
10
Propagation Delay
3.3
3.0
9
15
2.5
16.5
CP to TC
5.0
2.0
6
10.5
1.5
11.5
Propagation Delay
3.3
3.5
8.5
14
2.5
15.5
CP to TC
5.0
2.0
6.5
11
2.0
11.5
Propagation Delay
3.3
2.0
5.5
9.5
1.5
11
CET to TC
5.0
1.5
3.5
6.5
1.0
7.5
Propagation Delay
3.3
2.5
6.5
11
2.0
12.5
CET to TC
5.0
2.0
5
8.5
1.5
9.5
Propagation Delay
3.3
2.0
6.5
12
1.5
13.5
MR to Qn
5.0
1.5
5.5
9.5
1.5
10
Propagation Delay
3.3
3.5
10
15
3.0
17.5
MR to TC
5.0
2.5
8.5
13
2.5
13.5
ns
ns
ns
ns
ns
ns
ns
ns
Note 7: Voltage Range 3.3 is 3.3V ± 0.3V
Voltage Range 5.0 is 5.0V ± 0.5V
5
www.fairchildsemi.com
74AC161 • 74ACT161
DC Electrical Characteristics for ACT
74AC161 • 74ACT161
AC Operating Requirements for AC
Symbol
Parameter
VCC
TA = +25°C
(V)
CL = 50 pF
(Note 8)
tS
tH
tS
tH
tS
tH
tW
tW
tW
tREC
TA = −40°C to +85°C
CL = 50 pF
Typ
Units
Guaranteed Minimum
Setup Time, HIGH or LOW
3.3
6.0
13.5
16
Pn to CP
5.0
3.5
8.5
10.5
Hold Time, HIGH or LOW
3.3
−7.0
−1
−0.5
Pn to CP
5.0
−4.0
0
0
Setup Time, HIGH or LOW
3.3
6.5
11.5
14
PE to CP
5.0
4.0
7.5
8.5
Hold Time, HIGH or LOW
3.3
−6.0
0
0
PE to CP
5.0
−3.5
0.5
1
Setup Time, HIGH or LOW
3.3
3.0
6.0
7
CEP or CET to CP
5.0
2.0
4.5
5
Hold Time, HIGH or LOW
3.3
−3.5
0
0
CEP or CET to CP
5.0
−2
0
0.5
Clock Pulse Width
3.3
2.0
3.5
4
(Load) HIGH or LOW
5.0
2.0
2.5
3
Clock Pulse Width
3.3
2.0
4.0
4.5
(Count) HIGH or LOW
5.0
2.0
3.0
3.5
MR Pulse Width,
3.3
3.0
5.5
7.5
LOW
5.0
2.5
4.5
6.0
Recovery Time
−2
−0.5
0
MR to CP
−1
0
0.5
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Note 8: Voltage Range 3.3 is 3.3V ± 0.3V
Voltage Range 5.0 is 5.0V ± 0.5V
AC Electrical Characteristics for ACT
Symbol
fMAX
Parameter
Maximum Count
Frequency
tPLH
Propagation Delay CP to Qn
(PE Input HIGH or LOW)
tPHL
Propagation Delay CP to Qn
(PE Input HIGH or LOW)
tPLH
Propagation Delay
CP to TC
tPHL
Propagation Delay
CP to TC
tPLH
Propagation Delay
CET to TC
tPHL
Propagation Delay
CET to TC
tPHL
Propagation Delay
MR to Qn
tPHL
Propagation Delay
MR to TC
VCC
TA = +25°C
(V)
CL = 50 pF
CL = 50 pF
Min
Typ
5.0
115
125
5.0
1.5
5.5
9.5
1.5
10.5
ns
5.0
1.5
6.0
10.5
1.5
11.5
ns
5.0
2.0
7.0
11.0
1.5
12.5
ns
5.0
1.5
8.0
12.5
1.5
13.5
ns
5.0
1.5
5.5
8.5
1.5
10.0
ns
5.0
1.5
6.5
9.5
1.5
10.5
ns
5.0
1.5
6.0
10.0
1.5
11.0
ns
5.0
2.5
8.0
13.5
2.0
14.5
ns
6
Max
Min
Units
(Note 9)
Note 9: Voltage Range 5.0 is 5.0V ± 0.5V
www.fairchildsemi.com
TA = −40°C to +85°C
Max
100
MHz
Symbol
Parameter
VCC
TA = +25°C
(V)
CL = 50 pF
(Note 10)
tS
Setup Time, HIGH or LOW
Pn to CP
tH
Hold Time, HIGH or LOW
Pn to CP
Setup Time, HIGH or LOW
tS
PE to CP
tH
Hold Time, HIGH or LOW
PE to CP
tS
Setup Time, HIGH or LOW
CEP or CET to CP
tH
Hold Time, HIGH or LOW
CEP or CET to CP
tW
Clock Pulse Width,
(Load) HIGH or LOW
Clock Pulse Width,
tW
(Count) HIGH or LOW
tW
MR Pulse Width, LOW
tREC
Recovery Time
MR to CP
TA = −40°C to +85°C
CL = 50 pF
Typ
Units
Guaranteed Minimum
5.0
4.0
9.5
11.5
ns
5.0
−5.0
0
0
ns
5.0
4.0
8.5
9.5
ns
5.0
−5.5
−0.5
−0.5
ns
5.0
2.5
5.5
6.5
ns
5.0
−3.0
0
0
ns
5.0
2.0
3.0
3.5
ns
5.0
2.0
3.0
3.5
ns
5.0
3.0
3.0
7.5
ns
5.0
0
0
0.5
ns
Note 10: Voltage Range 5.0 is 5.0V ± 0.5V
Capacitance
Typ
Units
CIN
Symbol
Input Capacitance
Parameter
4.5
pF
VCC = OPEN
CPD
Power Dissipation Capacitance
45.0
pF
VCC = 5.0V
7
Conditions
www.fairchildsemi.com
74AC161 • 74ACT161
AC Operating Requirements for ACT
74AC161 • 74ACT161
Physical Dimensions inches (millimeters) unless otherwise noted
16-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-012, 0.150" Narrow
Package Number M16A
www.fairchildsemi.com
8
74AC161 • 74ACT161
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
16-Lead Small Outline Package (SOP), EIAJ TYPE II, 5.3mm Wide
Package Number M16D
9
www.fairchildsemi.com
74AC161 • 74ACT161
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
16-Lead Thin Shrink Small Outline Package (TSSOP), JEDEC MO-153, 4.4mm Wide
Package Number MTC16
www.fairchildsemi.com
10
74AC161 • 74ACT161 Synchronous Presettable Binary Counter
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
16-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300" Wide
Package Number N16E
Fairchild does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and
Fairchild reserves the right at any time without notice to change said circuitry and specifications.
LIFE SUPPORT POLICY
FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD
SEMICONDUCTOR CORPORATION. As used herein:
2. A critical component in any component of a life support
device or system whose failure to perform can be reasonably expected to cause the failure of the life support
device or system, or to affect its safety or effectiveness.
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the
body, or (b) support or sustain life, and (c) whose failure
to perform when properly used in accordance with
instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the
user.
www.fairchildsemi.com
11
www.fairchildsemi.com