DB Lectro N3753ABDC110P Suitable for automatic control, household electrical appliances and machinery electrical facilities. Datasheet

Présente / Presents:
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
N375
NHG RELAYS
Operation condition
N375
73.7 54.1 35.6
C
US
E160644
Features
heavy reverse power 30A/300VAC 28VDC
Optional mounting ways.
Firm structure, strong anti-shock & anti vibration.
Suitable for automatic control, household electrical appliances and machinery electrical facilities.
Insulation Resistance
100M
min (at 500VDC)
Item 7 of IEC255-5
Dielectric Strength
Between contacts
Between contact and coil
50Hz 2200V
50Hz 3750V
Item 6 of IEC255-5
IEC68-2-27 Test Ea
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
100m/s2 11ms
10~55Hz double amplitude 1.5mm
8N
235
2
3 0.5s
-25~60
85% (at 40 )
99g
Item 8 of IEC255-5
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua2
IEC68-2-20 Test Ta method 1
I EC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table
of IEC255-19-1 and minimum sample size 24.
Safety approvals
Safety approval
Ordering Information
N375 3C a DC12V P
2
3
4
30A/300VAC 2HP240VAC 1HP120VAC
Dimensions
5
1 Part number N375
2 Contact arrangement 3A:3A 3B:3B 3C:3C
3 Terminal a: inserting type b: PCB type
mm /inch
4 Coil rated voltage DC:6,12,24,48,110
AC: 6,12,24,48,120,208,240
5 Cover F:F mode; P:P mode; TM:TM model
2.750
0.170
Contact Data
Contact Arrangement
3A (3PSTNO)
Contact Material
Contact Rating
(Resistive)
Max. Switching Power
Max. Switching Voltage
Max. Resistance or
Voltage drop
Operation al Electrical
life
Mechanical
AgCdO AgSnO2
3B (3PSTNC) 3C (3PDT (B-M))
Max.
2.130max.
0.090 0.032
0.156
0.071
Max.
2.350max.
Max.
2.900max.
0.098
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
0.079
1 10
1 107
0.150
Item 3.12 of IEC255-7
5
2.500
2.350
Max. Switching Current:30A
50m
1.898
3A,3B,3C:30A/300VAC,28VDC; 2HP 240VAC , 1HP 120VAC
900W 9000VA
150VDC 380VAC
Max.
3.160max.
Max.
1.400 max.
0.062
1
UL&CUR
Load
0.059
0.055 0.032
0.250 0.031
0.625
Coil Parameter
DC
006-2600
012-2600
024-2600
048-2600
110-2600
6
12
24
48
110
75%o f
6.6
13.2
26.4
52.8
121
14
55
230
900
4900
rated voltage
4.5
9.0
18.0
36.0
82.5
10%o f
2
3
4
5
6
4
5
6
7
8
9
7
8
9
16.4
0.300
1
0.646
3
4.5VA
22.2
0.874
2- 1.8
0.071
22.2
0.874
Mounting (Bottom view)
1
rated voltage
0.6
1.2
2.4
4.8
11.0
9- 2.7
0.071
1.500
2
7.62
1.2
2.4
4.8
9.6
24.0
41.6
48.0
38.1
38.1
1.500
1
0.897
5.1
10.2
20.4
40.8
102.0
176.8
204.0
2.4
9.5
35
150
570
3075
3800
38.1
22.78
6.6
13.2
26.4
52.8
132
229
264
Dimensions
Release
Time
ms
7.62
6
12
24
48
120
208
240
Operate
Time
ms
0.300
006AC
012AC
024AC
048AC
120AC
208AC
240AC
COIL
POWER
0.897
AC
Release
voltage
V(min)
20%of rated
voltage
0.646
Max.
Pick up
voltage
V(max)
85%of rated
voltage
22.78
Rated
Coil
resistance
10%
16.4
Dash
numbers
Rated
voltage
V
2.6W
15
4
5
6
7
8
9
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
3
8
9
1
2
3
4
5
6
7
8
9
5
3A
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
7
2
3C
3B
Wiring diagram (Bottom view)
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
Ningbo Huaguan Relay Corporation LTD.