DYELEC GBU10005 Low forward voltage drop Datasheet

GBU10005 THRU GBU1010
SINGLE PHASE 10.0AMP GLASS PASSIVATED BRIDGE RECTIFIER
Features
GBU
· Glass passivated die construction
· Low forward voltage drop
· High current capability
· High surge current capability
· Plastic material-UL flammability 94V-0
Mechanical Data
· Case: G B U , molded plastic
· Terminals: Plated Leads Solderable per
·
·
·
·
MIL-STD-202, Method 208
Polarity: As Marked on Case
Mounting Position: Any
Marking: Type Number
Lead Free: For RoHS / Lead Free Version
dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ ambient temperature unless otherwise specified.
Single Phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
SYMBOL GBU
GBU
10005 1001
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
VRRM
VRWM
RMS Reverse Voltage
VRMS
GBU
GBU
GBU
GBU
1002 1004
1006
1008
1010
GBU
UNITS
50
100
200
400
600
800
1000
V
35
70
140
280
420
560
700
V
VDC
IO
Average Rectified Output Current (Note 1)@TA =40℃
A
10.0
Non-Repetitive Peak Forward Surge Current 8.3ms
Single half sine-wave superimposed on rated load
(JEDEC Method)
IFSM
200
A
@IF=5A
@IF=10A
VFM
1.0
1.1
V
IR
5.0
500
uA
CJ
70
pF
RθJA
25
RθJL
2.2
Forward Voltage per element
Peak Reverse Current
At Rated DC Blocking Voltage
@TA =25 ℃
@TA =125 ℃
Typical Junction Capacitance per leg
Typical Thermal Resistance per leg (Note 2)
Operating and Storage Temperature Range
TJ,TSTG
℃/W
℃
-55to+150
2
Note:1. Mounted on glass epoxy PC board with 1.3mm solder pad.
2. Measured at 1.0 MHz and applied reverse voltage of 4.0V D.C.
version:01
1 of 2
www.dyelec.com
20
15
10
5
0
100
50
TA, AMBIENT TEMPERATURE (°C)
150
IF, INSTANTANEOUS FORWARD CURRENT (A)
Fig. 1 Output Current Derating Curve
Fig. 2 Typical Forward Characteristics (per leg)
50
5
0.5
0.05
0.4
TA= 25°C
Pulse Width = 300µs
0.6
0.8
1.0
1.2
1.4
1.6
VF, INSTANTANEOUS FORWARD VOLTAGE (V)
Fig. 4 Typical Junction Capacitance
Fig. 3 Maximum Peak Forward Surge Current (per leg)
400
350
300
250
200
150
100
50
0
TA = 25°C
Single Half Sine-Wave
Pulse Width = 8.3ms
(JEDEC Method)
1
10
NUMBER OF CYCLES AT 60 Hz
100
INSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
IFSM, PEAK FORWARD SURGE CURRENT (A)
I(AV), AVERAGE FORWARD RECTIFIED CURRENT (A)
GBU10005 THRU GBU1010
10
1.0
T A=25°C
0.1
0.01
0
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE
version:01
2 of 2
www.dyelec.com