CANDD HL01U 1 watt unregulated dc/dc converter Datasheet

Product Data Sheet
1 WATT UNREGULATED
DC/DC CONVERTER
HL01U
FEATURES
●
●
●
●
● HIGH EFFICIENCY
● NON-CONDUCTIVE CASE
● SURFACE MOUNT PACKAGE (SMD)
LOW COST
INTERNAL FILTERING
SURFACE MOUNT CONSTRUCTION
TEMPERATURE RANGE: -25°C TO +70°C
DESCRIPTION
The HL01U Series offers an extensive selection of input
and output voltages to choose from. These miniature,
unregulated DC/DC converters come in 24-pin DIP and
SMD packages. This small size is possible through the use
of surface mount manufacturing technologies.
The HL01U Series utilizes a 125KHz push-pull oscillator
in the input stage with internal filtering to reduce the
output noise.
ABSOLUTE MAXIMUM RATINGS
ORDERING INFORMATION
Internal Power Dissipation..................................................................30 Sec
Short Circuit Duration..................................................................Momentary
Lead Temperature (soldering, 10 seconds max)..............................+300°C
*
* Note: Refer to Reflow Profile for SMD Models.
The use of surface mount construction and automated
manufacturing processes increase consistency and reliability while reducing overall cost.
HL01U xxyzz Y/Z /H
Device Family
HL Indicates DC/DC Converter
Model Number
Where:
xx = Input Voltage
y = Number or Outputs (Single "S", Dual "D")
zz = Output Voltage
Package Option
Screening Option
DIP Package only
Internet: http://www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Phone: 800.547.2537
Fax: 520.770.9369
HL01UrevD,10/97
Power Electronics Division, Europe
C&D Technologies (Power Electronics) Ltd.
132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland
Tel: +353.61.474.133
Fax:+353.61.474.141
Page 1
ELECTRICAL SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
NOMINAL
INPUT
VOLTAGE
MODEL
RATED
OUTPUT
VOLTAGE
RATED
OUTPUT
CURRENT
INPUT CURRENT
NO LOAD
RATED LOAD
(mA)
EFFICIENCY
(VDC)
(VDC)
(mA)
(mA)
(%)
HL01U05S05
HL01U05S12
HL01U05S15
5
5
5
5
12
15
200
83
67
30
30
30
300
260
260
70
74
74
HL01U12S05
HL01U12S12
HL01U12S15
12
12
12
5
12
15
200
83
67
25
25
25
120
120
120
67
70
70
HL01U15S05
HL01U15S12
HL01U15S15
15
15
15
5
12
15
200
83
67
20
20
20
100
100
100
67
70
70
HL01U24S05
HL01U24S12
HL01U24S15
24
24
24
5
12
15
200
83
67
15
15
15
65
65
65
67
70
70
HL01U05D05
HL01U05D12
HL01U05D15
5
5
5
±5
±12
±15
±100
±41
±33
30
30
30
300
260
260
70
74
74
HL01U12D05
HL01U12D12
HL01U12D15
12
12
12
±5
±12
±15
±100
±41
±33
25
25
25
120
120
120
67
70
70
HL01U15D05
HL01U15D12
HL01U15D15
15
15
15
±5
±12
±15
±100
±41
±33
20
20
20
100
100
100
67
70
70
HL01U24D05
HL01U24D12
HL01U24D15
24
24
24
±5
±12
±15
±100
±41
±33
15
15
15
65
65
65
67
70
70
TYP
MAX
UNITS
5
12
15
24
30
5.5
13.2
16.5
26.4
100
VDC
COMMON SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
PARAMETER
CONDITIONS
INPUT
Voltage Range
MIN
4.5
10.8
13.5
22.6
Reflected Ripple Current
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
OUTPUT
Rated Power
Voltage Setpoint Accuracy
Temperature Coefficent
Ripple & Noise
Line Regulation
Load Regulation
5 Vout Models
All Others
GENERAL
Switching Frequency
Package Weight
MTTF per MIL-HDBK-217, Rev. F
Ground Benign
TEMPERATURE
Specification
Operation
Storage
Page 2
60 Hz, 10 Seconds
500
500
VDC
mAp-p
VDC
Vpk
GΩ
pF
µArms
VISO= 240VAC, 60Hz
1
25
2
BW = DC to 10MHz
BW =10Hz to 2MHz
High Line to Low Line
1
±3
±0.02
50
10
1
±1.5
W
%
%/°C
mVp-p
mVrms
%/%
25% Rated Load to Rated Load
10% Rated Load to Rated Load
±5
±3
±10
±10
%
%
Circuit Stress Method
TA = +25°C
TA = +70°C
-25
-40
-40
±5
100
125
12
kHz
g
1100
550
kHr
kHr
+70
+85
+110
°C
°C
°C
HL01UrevD,10/97
MECHANICAL
Package/Pinout "Y" and "Z"
1.285±0.010"
(32.64±0.25)
1.285±0.010"
(32.64±0.25)
2423 22
0.525±0.010"
(13.34±0.25)
2423 22
1514 13
0.525±0.010"
(13.34±0.25)
HL01UxxyzzY
1 2 3
SIDE VIEWS
0.695±0.015"
(17.65±0.38)
10 11 12
0.375±0.005"
(9.52±0.13)
0.015±0.005"
(0.38±0.13)
0.020±0.002"
(0.51±0.05)
0.100±0.010"
(2.54±0.25)
HL01UxxyzzZ
1 2 3
10 11 12
0.375±0.005"
(9.52±0.13)
0.015±0.005"
(0.38±0.13)
1514 13
TOP VIEWS
0.100±0.010"
(2.54±0.25)
0.020±0.002"
(0.51±0.05)
END VIEWS
0°-15°
0.600"
(15.24)
0.125+0.030"
-0.000"
(3.18+0.76)
(
-0.00)
0.014±0.002"
(0.36±0.05)
DIP PACKAGE
.015±.010"
(.38±.25)
SMD PACKAGE
NU = Do Not Use.
NC = No Internal Connection.
PIN CONNECTIONS
Duplicate pin functions are internally connected.
PIN#
All dimensions are in inches (millimeters).
GRID: 0.100 inches (2.54 millimeters)
Typically Marked with: specific model ordered, date
code, job code and Logo.
RECOMMENDED LAND PATTERN
SINGLES
DUALS
1
2
3
+VIN
NU
NU
+VIN
-VOUT
Common
10
11
12
-VOUT
+VOUT
-VIN
Common
+VOUT
-VIN
13
14
15
-VIN
+VOUT
-VOUT
-VIN
+VOUT
Common
22
23
24
NU
NU
+VIN
Common
-VOUT
+VIN
RECOMMENDED REFLOW PROFILE
30 sec MAX
(>220°C)
0.100"
(2.54)
250
235 °C MAX
2423 22
220
1514 13
200
0.040"
(1.02)
1 2 3
10 11 12
1.150"
(29.21)
190
TEMPERATURE (°C)
0.080"
(2.03)
0.730"
(18.54)
150
100
90 sec MAX
(>190°C)
50
TIME (seconds)
HL01UrevD,10/97
Page 3
TYPICAL PERFORMANCE CURVES
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
VOUT VS LOAD
(±5Vout Models)
5.9
6.0
13.6
5.6
5.3
5.7
5.4
5.0
5.1
4.7
4.8
50
100
150
Vout (Volts)
14.0
0
200
13.2
12.8
12.4
12.0
0
25
Load (mA)
50
75
100
0
VOUT VS LOAD
(15Vout Models)
15.8
15.6
12.0
Vout (Volts)
12.6
Vout (Volts)
15.8
12.2
15.5
15.2
20
30
0
40
30
40
15.4
15.2
14.8
14.6
10
80
15.0
14.9
11.8
60
VOUT VS LOAD
(±15Vout Models)
16.1
12.4
40
Load (mA)
12.8
0
20
Load (mA)
VOUT VS LOAD
(±12Vout Models)
Vout (Volts)
VOUT VS LOAD
(12Vout Models)
6.3
Vout (Volts)
Vout (Volts)
VOUT VS LOAD
(5Vout Models)
6.2
20
Load (mA)
40
60
80
0
20
10
Load (mA)
Load (mA)
EFFICIENCY VS LOAD
Efficiency (%)
1.0
0.8
0.6
0.4
0.2
0.0
0
25
50
75
100
Load (mA)
SAFE OPERATING AREA
LOAD CAPACITANCE vs INPUT RISE TIME
(5 Vout models)
600
50
Total Load Capacitance (uF)
Total Load Capacitance (uF)
500
400
300
SAFE OPERATING AREA
200
40
30
SAFE OPERATING AREA
20
10
100
0
0
0
5
10
15
20
25
30
35
Rise Time of Input Voltage (mS)
40
45
5
10
15
20
25
30
35
40
45
50
Rise Time of Input Voltage (mS)
LOAD CAPACITANCE vs INPUT RISE TIME
(12 Vout models)
NOTES:
1.) When operated within the SAFE OPERATING AREA as defined
by the above curves, the output voltage of HL01U devices is
guaranteed to be within 95% of its steady-state value within 100
milliseconds after the input voltage has reached 95% of its steadystate value.
80
70
60
50
SAFE OPERATING AREA
40
0
50
90
Total Load Capacitance (uF)
LOAD CAPACITANCE vs INPUT RISE TIME
(15 Vout models)
60
30
20
2.) For dual output models, total load capacitance is the sum of the
capacitances on the plus and minus outputs.
10
0
0
5
10
15
20
25
30
35
40
45
50
Rise Time of Input Voltage (mS)
Page 4
HL01UrevD,10/97
Similar pages