AAC MSA34A24T1V1 Msa low capacitance max guardâ® esd suppressor array Datasheet

MSA Low Capacitance MAX Guard® ESD Suppressor Array
The content of this specification may change without notification 10/12/07
FEATURES
•
•
•
•
APPLICATIONS
HOW TO ORDER
MSA
24
A
05
T
1
V1
Product
Code
Size
Tolerance
Operating
Voltage
Packaging
Typical
Clamping
Voltage
Typical
Trigger
Voltage
24:
0402X
4
34:
0603X
4
MAX
Guard
Suppress
or
Low capacitance (<0.2pF)
Ultra low leakage current (<1nA)
Fast response time
Bi-direction device
A: Suit For
IEC6100-4-2
C: Suit For
IEC6100-4-2 &
AEC-Q200
03: 3.3V
05: 5.5V
12: 12V
24: 24V
T: Paper Tape
(5K/10K)
1: 17V
2: 25V
•
•
•
•
•
•
•
•
V1: 150V V2:
250V
SCHEMATIC
Cell / smart phone
Computers / Laptops
Digital cameras
PDA’s
Plasma display panels / LCD / TVs/ HDTVs
Mp3 / Multimedia players
Scanner / Printer
High speed data ports USB 2.0, IEEE1394
DIMENSIONS (mm)
Size
L
W
T
MS04 (0402)
2.0±0.1
1.0±0.
1
0.45±0.
1
P
0.5±0.1
MS06 (0603)
3.2±0.2
1.5±0.
2
0.6±0.1
0.8±0.1
A
B
C
D
G
0.3±0.1
0.2±.0.1
0.3±0.
1
0.15±0.
1
0.25±0.1
5
0.6±0.1
0.3±0.2
0.5±0.
1
0.25±0.
1
0.35±0.1
5
ELECTRICAL CHARACTERISTICS
Type
MSA24A03T1V1
MSA24A03T2V2
MSA24A05T1V1
MSA24A05T2V2
MSA24A12T1V1
MSA24A12T2V2
MSA24A24T1V1
MSA24A24T2V2
MSA34A03T1V1
MSA34A03T2V2
MSA34A05T1V1
MSA34A05T2V2
MSA34A12T1V1
MSA34A12T2V2
MSA34A24T1V1
MSA34A24T2V2
•
•
•
•
Continuous
Operating
Voltage
(Max.)
ESD
Capability
3.3 VDC
5.5 VDC
12 VDC
Direct
Discharge:
8KV Air
Discharge:1
5KV
24 VDC
3.3 VDC
5.5 VDC
12 VDC
24 VDC
Direct
Discharge:
8KV Air
Discharge:1
5KV
Trigger
Voltage
(Typ.)
Clamping
Voltage
(Typ.)
150V
250V
150V
250V
150V
250V
150V
250V
150V
250V
150V
250V
150V
250V
150V
250V
17V
25V
17V
25V
17V
25V
17V
25V
17V
25V
17V
25V
17V
25V
17V
25V
Capacitance
Leakage
Current
(Typ.)
Response
Time
ESD Pulse
Withstand
(Typ.)
<0.02pF
<10nA
<1ns
>1000 pulses
<0.02pF
<10nA
<1ns
>1000 pulses
The function meets with the requirement of IEC 61000-4-2 specification.
Trigger measurement made using Transmission Line Pulse method.
Capacitance measured at 1 M~1.8 GHz.
Performing under IEC 61000-4-2 level 4 (8KV contact discharge, 15KV air discharge).