The Bel Power Solutions MAP30/40/42 Series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety, EMI and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. Fixed frequency operation simplifies system level operation. The MAP30/40/42 Series is configured to the international standard 3 x 5 inch footprint. Input and output connections are made via popular single-row Molex connectors. Single output models feature widerange output adjustability to meet a wide variety of standard and userspecific output voltage requirements. Universal Input 85-264 VAC Input Transient & ESD Compliance to EN61000-4-2/-3/-4 Meets EN55022 Conducted and Radiated Limits Greater than 311,000 Hours MTBF Remote Sense (MAP30, MAP42) RoHS Compliant CE Marked to Low Voltage Directive MAP30/40/42 Series 2 MODEL 9 OUTPUT VOLTAGE ADJUSTMENT RANGE MAX OUTPUT CURRENT PEAK OUTPUT CURRENT 1 LINE REGULATION LOAD REGULATION RIPPLE & NOISE 2 INITIAL SETTING ACCURACY MAP30-1005G 5V 4.7V to 5.8V 6A 8A 8 0.2% ±1% 1% 4.9V to 5.1V MAP42-1005 5V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V 3 0.2% 1% 1% 11.9V to 12.1V 2.3/1.9A 3 0.2% 1% 1% 23.8V to 24.2V 3 MAP42-1012G 12V/15V 11V to 18V 3.4/2.7A MAP42-1024G 24V/28V 23V to 29V 1.7/1.4A 3 PEAK OUTPUT CURRENT 4 LINE REGULATION 3A 5A 2A 3.5A MODEL 9 OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT +5V 4.7V to 5.5V MAP40-3000G +12V Fixed MAP40-3100G MAP40-3101G MAP40-3105G MAP40-3500G MAP40-3003G 4.6/3.7A LOAD REGULATION RIPPLE & NOISE 2 0.2% 2% 1% 4.9V to 5.1V 1% 3.5% 5 1% 11.5V to 12.5V 1% -11.5V to -12.5V 1% 4.9V to 5.1V 1% 11.5V to 12.5V -12V Fixed 0.3A 0.5A 1% +5V 4.75V to 5.25V 3A 5A 0.2% +12V 2% 6 2% 5 INITIAL SETTING ACCURACY Fixed 2A 3.5A 1% 3.5% -12V Fixed 0.3A 0.5A 1% 2% 1% -11.4V to -12.6V +5V 4.75V to 5.25V 3A 5A 0.2% 2% 1% 4.9V to 5.1V +24V Fixed 1A 1.5A 1% 3.5% 5 1% 23.0V to 25.0V -12V Fixed 0.3A 0.5A 1% 2% 1% -11.5V to -12.5V +5V 4.7V to 5.8V 3A 5A 0.2% 2% 1% 4.9V to 5.1V +12V Fixed 2A 3.5A 1% 3.5% 5 1% 11.5V to 12.5V -5V Fixed 0.5A 1A 1% 2% 1% -4.75V to -5.25V +5V 4.7V to 5.8V 5A 6A 0.2% 2% 1% 4.9V to 5.1V 1% 11.5V to 12.5V -11.4V to -12.6V 5 +12V Fixed 1A 3.5A 1% 3.5% -12V Fixed 0.3A 0.5A 1% 2% 1% +5V 4.7V to 5.8V 3A 5A 0.2% 2% 1% 4.9V to 5.1V +15V Fixed 1.5A 3A 1% 3.5% 5 1% 14.7V to 15.3V 1% -14.3V to -15.7V -15V Fixed 0.2A 0.5A 1% 2% 6 MAXIMUM OUTPUT POWER 40 W 7 40 W 7 40 W 7 40 W 7 40 W 7 40 W 7 1 Peak ratings may be used as maximum output current with 100 Linear Feet per Minute (LFM) forced air cooling. Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3 MAP42-1012G output currents are expressed as 12V/15V operation. MAP42-1024G output currents are expressed as 24V/28V operation. 4 Peak loads for 30 seconds or less are acceptable, (10% duty cycle max.). 5 Quasi regulated output. See Regulation Curves for more information. 6 Requires a minimum load of 0.5A on V1 or 0.3A on V2. 7 Needs 170 LFM forced air cooling for use at 50°C ambient. 8 Needs 200 LFM forced air cooling for use at 50°C ambient. 9 Non-G models use lead solder exemption and are not recommended for new designs. Xxx Model highlighted in yellow is not recommended for new designs. 2 [email protected] MAP30/40/42 Series PARAMETER 3 CONDITIONS / DESCRIPTION MIN MAP42 MAP30, MAP40 MAX UNITS 85 90 NOM 264 264 VAC 63 Hz Input Voltage - AC Continuous input range Input Frequency AC input 47 Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC Hold-up Time Nominal AC Input Voltage (115VAC), full rated load. 15 ms Input Current 90 VAC (40W load). Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor, Vin = 264 VAC (one cycle), 25° C Operating Frequency Switching frequency of power supply (fixed frequency). PARAMETER CONDITIONS / DESCRIPTION Efficiency Full load @120 VAC Minimum Loads Single output models; MAP30, MAP42. All multiple output models, see regulation graphs. Ripple and Noise Full load, 20 MHz bandwidth. Output Power Multiple output models with convection cooling. 40 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on, V1. 1 % Regulation Transient Response 23 25 MIN NOM 30 kHz MAX UNITS See Model Selection Chart. Varies by output, total regulation includes: Line changes from 90132 VAC or 175-264, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output only of multiple output units). See regulation graphs. μs 500 Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 PARAMETER CONDITIONS / DESCRIPTION MIN MAP30-1005G, MAP42-1005 MAP42-1012G MAP42-1024G Main output only of multiple output units. Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. 5.8 20.0 32.0 5.8 8 APK Amps 1 Remote Sense 38 70% typical Time required for initial output voltage stabilization. Overload Protection ARMS 0.0 Turn-on Delay Overvoltage Protection 1.2 NOM 2 ms MAX UNITS 6.8 22.0 37.0 6.8 V 130 Total cable drop, single output models only. Sec % 250 mV Power Fail Warning is not available for MAP80-1024G. The MAP80-1012G is an open collector output, capable of sinking 35 mA, maximum. Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection BCD.00563_AC Asia-Pacific +86 755 298 85888 MAP30/40/42 Series 4 PARAMETER CONDITIONS / DESCRIPTION MIN Approved to the latest edition of the following standards; Agency Approvals UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd. Input to Chassis Dielectric Withstand Voltage Input to Output (tested by manufacturer only) FCC CFR title 47 part 15 sub-part B - conducted Electromagnetic EN55022 / CISPR 22 conducted (Note 1) Interference EN55022 / CISPR 22 radiated (Note 2) Line to Line Input Transient Protection EN61000-4-5 Level 3 Line to Ground Insulation Resistance Leakage Current PARAMETER Altitude Operating Temperature UNITS VDC B B B Class 1 2 kV 7 MΩ MAP42, MAP40-3100G/3001G/3105G/3500G MAP30-1005G, MAP40-3000G, MAP40-3003G 500 μA 750 CONDITIONS/DESCRIPTION MIN Operating Non-operating Derate linearly above 50°C by 2.5% per °C to a maximum temperature of 70°C MAX 2121 4242 Input to output Per EN60950, 264VAC NOM At 100% load: At 50% load: Storage Temperature NOM MAX UNITS 0 0 10k 40k 50 70 -40 85 °C ±0.03 %/°C 95 %RH ±0.02 ASL Ft. °C Temperature Coefficient 0°C to 70°C (after 15 minute warm-up) Relative Humidity Non-condensing Shock Operating, peak acceleration 20 G Vibration Random vibration, 10Hz to 2kHz, 3 axis 6 GRMS 5 14.25 13.75 13.25 12.75 +5V @ 5.0 Amps 12.25 +5V @ 3.0 Amps +5V @ 1.0 Amps 11.75 +5V @ 0 Amps 11.25 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 12V OUTPUT CURRENT Figure1. MAP40-3500G Typical Quasi Regulation Performance For +12V Output [email protected] MAP30/40/42 Series 5 13.5 13.0 12.5 12.0 +5V @ 3.0 Amps +5V @ 1.8 Amps 11.5 +5V @ 0.6 Amps +5V @ 0 Amps 11.0 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 12V OUTPUT CURRENT Figure 2. MAP40-3000/3100/3105G Typical Quasi Regulation Performance For +12V Output 17.0 16.5 16.0 15.5 15.0 +5V @ 3.0 Amps +5V @ 1.8 Amps 14.5 +5V @ 0.6 Amps +5V @ 0 Amps 14.0 13.5 0 0.15 0.3 0.45 0.6 0.75 0.9 1.05 1.2 1.35 1.5 15V OUTPUT CURRENT Figure 3. MAP40-3003G Typical Quasi Regulation Performance For +15V Output J1 NEUTRAL LINE MAP30 J2 PIN 1 PIN 7 PIN 2 J3 SAFETY EARTH GROUND (0.250" x 0.032" FASTON) PIN 1 MAP40 J2 N/C V1 V1 GND GND +Sense -Sense PIN 6 PIN 1 MAP42 J2 V2 V1 V1 GND GND V3 PIN 6 V1 V1 GND GND +Sense -Sense PIN 1 J1/J2 MATES WITH MOLEX (SERIES 2139 or SERIES 41695) .156" (4mm) CENTER CRIMP TERMINAL HOUSING OR EQUIVALENT Figure 4. Electrical Connectors PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX 127.0 x 76.2 x see table below 5.0 x 3.0 x see table below 0.26 0.6 Dimensions Weight UNITS mm in kg lb Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection BCD.00563_AC Asia-Pacific +86 755 298 85888 MAP30/40/42 Series 6 SINGLE OUTPUT MODELS MULTIPLE OUTPUT MODELS Model Height Model Height MAP30-1005G 1.16" (29.5) MAP40-3000G 1.16" (29.5) MAP42-1005 1.25" (31.8) MAP40-3003G 1.16" (29.5) MAP42-1012G 1.25" (31.8) MAP40-3100G 1.25" (31.8) MAP42-1024G 1.25" (31.8) MAP40-3101G 1.25" (31.8) MAP40-3105G 1.25" (31.8) MAP40-3500G 1.60" (40.6) Table 1. MAP30/40/42 Series Height . . Figure 1. Mechanical Drawing NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. [email protected]