EPCOS B72210S0111K101 Siov metal oxide varistor Datasheet

SIOV metal oxide varistors
Leaded varistors, StandarD series
Series/Type:
S05, S07, S10, S14, S20
Date:
December 2007
Data Sheet
 EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures
hereto and the information contained therein without EPCOS’ prior express consent is prohibited.
Leaded varistors
StandarD series
Construction
■ Round varistor element, leaded
■ Coating: epoxy resin, flame-retardant to UL 94 V-0
■ Terminals: tinned copper wire
Features
■
■
■
■
Wide operating voltage range 11 … 1100 VRMS
High surge current ratings up to 8 kA
No derating up to 85 °C ambient temperature
PSpice models
Approvals
■
■
■
■
■
■
■
UL
CSA (all types ≥K115)
SEV
VDE
CECC
CQC S05/07 (K11 … K460), S10/S14 (K11 … K680), S20 (K11 … K1100)
IEC
Delivery mode
■ Bulk (standard), taped versions on reel or in Ammo pack upon request.
■ For further details refer to chapter “Taping, packaging and lead configuration” for leaded varistors.
Options
S10* types with lead spacing 5.0 mm and S20* types with lead spacing 7.5 mm are also available
on request.
General technical data
Climatic category
Operating temperature
Storage temperature
Electric strength
Insulation resistance
Response time
to IEC 60068-1
to CECC 42 000
to CECC 42 000
to CECC 42 000
Please read Cautions and warnings and
Important notes at the end of this document.
2
11/07
40/85/56
– 40 … + 85
– 40 … +125
≥2.5
≥10
<25
°C
°C
kVRMS
MΩ
ns
Leaded varistors
StandarD series
Maximum ratings (TA = 85 °C)
VRMS
VDC
B72205S0110K101
B72207S0110K101
B72210S0110K101
B72214S0110K101
B72220S0110K101
Type
(untaped)
SIOVS05K11
S07K11
S10K11
S14K11
S20K11
Wmax
(2 ms)
J
0.3
0.8
1.7
3.2
10.0
Pmax
V
14
14
14
14
14
imax
(8/20 µs)
A
100
250
500
1000
2000
V
11
11
11
11
11
B72205S0140K101
B72207S0140K101
B72210S0140K101
B72214S0140K101
B72220S0140K101
S05K14
S07K14
S10K14
S14K14
S20K14
14
14
14
14
14
18
181)
181)
181)
181)
100
250
500
1000
2000
0.4
0.9
2.0
4.0
12.0
0.01
0.02
0.05
0.10
0.20
B72205S0170K101
B72207S0170K101
B72210S0170K101
B72214S0170K101
B72220S0170K101
S05K17
S07K17
S10K17
S14K17
S20K17
17
17
17
17
17
22
22
22
22
22
100
250
500
1000
2000
0.5
1.1
2.5
5.0
14.0
0.01
0.02
0.05
0.10
0.20
B72205S0200K101
B72207S0200K101
B72210S0200K101
B72214S0200K101
B72220S0200K101
S05K20
S07K20
S10K20
S14K20
S20K20
20
20
20
20
20
26
26
26
26
26
100
250
500
1000
2000
0.6
1.3
3.1
6.0
18.0
0.01
0.02
0.05
0.10
0.20
B72205S0250K101
B72207S0250K101
B72210S0250K101
B72214S0250K101
B72220S0250K101
S05K25
S07K25
S10K25
S14K25
S20K25
25
25
25
25
25
31
31
31
31
31
100
250
500
1000
2000
0.7
1.6
3.7
7.0
22.0
0.01
0.02
0.05
0.10
0.20
B72205S0300K101
B72207S0300K101
B72210S0300K101
B72214S0300K101
B72220S0300K101
S05K30
S07K30
S10K30
S14K30
S20K30
30
30
30
30
30
38
38
38
38
38
100
250
500
1000
2000
0.9
2.0
4.4
9.0
26.0
0.01
0.02
0.05
0.10
0.20
Ordering code
1) Jump-start strength (max. 24 V, 5 minutes)
Please read Cautions and warnings and
Important notes at the end of this document.
3
11/07
W
0.01
0.02
0.05
0.10
0.20
Leaded varistors
StandarD series
Characteristics (TA = 25 °C)
B72205S0110K101
B72207S0110K101
B72210S0110K101
B72214S0110K101
B72220S0110K101
Vv
(1 mA)
V
18
18
18
18
18
∆Vv
(1 mA)
%
±10
±10
±10
±10
±10
vc, max
(ic)
V
36
36
36
36
36
A
1.0
2.5
5.0
10.0
20.0
Ctyp
(1 kHz)
pF
1750
2750
6250
12100
23000
B72205S0140K101
B72207S0140K101
B72210S0140K101
B72214S0140K101
B72220S0140K101
22
22
22
22
22
±10
±10
±10
±10
±10
43
43
43
43
43
1.0
2.5
5.0
10.0
20.0
1450
2300
5200
9950
19000
B72205S0170K101
B72207S0170K101
B72210S0170K101
B72214S0170K101
B72220S0170K101
27
27
27
27
27
±10
±10
±10
±10
±10
53
53
53
53
53
1.0
2.5
5.0
10.0
20.0
1200
1900
4350
8200
15600
B72205S0200K101
B72207S0200K101
B72210S0200K101
B72214S0200K101
B72220S0200K101
33
33
33
33
33
±10
±10
±10
±10
±10
65
65
65
65
65
1.0
2.5
5.0
10.0
20.0
980
1600
3650
6800
13000
B72205S0250K101
B72207S0250K101
B72210S0250K101
B72214S0250K101
B72220S0250K101
39
39
39
39
39
±10
±10
±10
±10
±10
77
77
77
77
77
1.0
2.5
5.0
10.0
20.0
850
1400
3200
5850
11100
B72205S0300K101
B72207S0300K101
B72210S0300K101
B72214S0300K101
B72220S0300K101
47
47
47
47
47
±10
±10
±10
±10
±10
93
93
93
93
93
1.0
2.5
5.0
10.0
20.0
720
1200
2750
4950
9350
Ordering code
Please read Cautions and warnings and
Important notes at the end of this document.
4
11/07
ic
Leaded varistors
StandarD series
Maximum ratings (TA = 85 °C)
VRMS
VDC
B72205S0350K101
B72207S0350K101
B72210S0350K101
B72214S0350K101
B72220S0350K101
Type
(untaped)
SIOVS05K35
S07K35
S10K35
S14K35
S20K35
imax
(8/20 µs)
A
100
250
500
1000
2000
Wmax
(2 ms)
J
1.1
2.5
5.4
10.0
33.0
Pmax
V
35
35
35
35
35
V
45
45
45
45
45
B72205S0400K101
B72207S0400K101
B72210S0400K101
B72214S0400K101
B72220S0400K101
S05K40
S07K40
S10K40
S14K40
S20K40
40
40
40
40
40
56
56
56
56
56
100
250
500
1000
2000
1.3
3.0
6.4
13.0
37.0
0.01
0.02
0.05
0.10
0.20
B72205S0500K101
B72207S0500K101
B72210S0500K101
B72214S0500K101
B72220S0500K101
S05K50
S07K50
S10K50
S14K50
S20K50
50
50
50
50
50
65
65
65
65
65
400
1200
2500
4500
6500
1.8
4.2
8.4
15.0
27.0
0.10
0.25
0.40
0.60
1.00
B72205S0600K101
B72207S0600K101
B72210S0600K101
B72214S0600K101
B72220S0600K101
S05K60
S07K60
S10K60
S14K60
S20K60
60
60
60
60
60
85
85
85
85
85
400
1200
2500
4500
6500
2.2
4.8
10.0
17.0
33.0
0.10
0.25
0.40
0.60
1.00
B72205S0750K101
B72207S0750K101
B72210S0750K101
B72214S0750K101
B72220S0750K101
S05K75
S07K75
S10K75
S14K75
S20K75
75
75
75
75
75
100
100
100
100
100
400
1200
2500
4500
6500
2.5
5.9
12.0
20.0
40.0
0.10
0.25
0.40
0.60
1.00
B72205S0950K101
B72207S0950K101
B72210S0950K101
B72214S0950K101
B72220S0950K101
S05K95
S07K95
S10K95
S14K95
S20K95
95
95
95
95
95
125
125
125
125
125
400
1200
2500
4500
6500
3.4
7.6
15.0
25.0
50.0
0.10
0.25
0.40
0.60
1.00
Ordering code
Please read Cautions and warnings and
Important notes at the end of this document.
5
11/07
W
0.01
0.02
0.05
0.10
0.20
Leaded varistors
StandarD series
Characteristics (TA = 25 °C)
Ordering code
B72205S0350K101
B72207S0350K101
B72210S0350K101
B72214S0350K101
B72220S0350K101
Vv
(1 mA)
V
56
56
56
56
56
∆Vv
(1 mA)
%
±10
±10
±10
±10
±10
vc, max
(ic)
V
110
110
110
110
110
ic
1.0
2.5
5.0
10.0
20.0
Ctyp
(1 kHz)
pF
620
1050
2400
4200
8000
A
B72205S0400K101
B72207S0400K101
B72210S0400K101
B72214S0400K101
B72220S0400K101
68
68
68
68
68
±10
±10
±10
±10
±10
135
135
135
135
135
1.0
2.5
5.0
10.0
20.0
520
900
2100
3550
6750
B72205S0500K101
B72207S0500K101
B72210S0500K101
B72214S0500K101
B72220S0500K101
82
82
82
82
82
±10
±10
±10
±10
±10
135
135
135
135
135
5.0
10.0
25.0
50.0
100.0
300
530
950
1800
3800
B72205S0600K101
B72207S0600K101
B72210S0600K101
B72214S0600K101
B72220S0600K101
100
100
100
100
100
±10
±10
±10
±10
±10
165
165
165
165
165
5.0
10.0
25.0
50.0
100.0
250
480
870
1650
3600
B72205S0750K101
B72207S0750K101
B72210S0750K101
B72214S0750K101
B72220S0750K101
120
120
120
120
120
±10
±10
±10
±10
±10
200
200
200
200
200
5.0
10.0
25.0
50.0
100.0
210
430
720
1370
2900
B72205S0950K101
B72207S0950K101
B72210S0950K101
B72214S0950K101
B72220S0950K101
150
150
150
150
150
±10
±10
±10
±10
±10
250
250
250
250
250
5.0
10.0
25.0
50.0
100.0
135
260
530
870
1830
Please read Cautions and warnings and
Important notes at the end of this document.
6
11/07
Leaded varistors
StandarD series
Maximum ratings (TA = 85 °C)
VRMS
VDC
B72205S0111K101
B72207S0111K101
B72210S0111K101
B72214S0111K101
B72220S0111K101
Type
(untaped)
SIOVS05K115
S07K115
S10K115
S14K115
S20K115
V
115
115
115
115
115
V
150
150
150
150
150
B72205S0131K101
B72207S0131K101
B72210S0131K101
B72214S0131K101
B72220S0131K101
S05K130
S07K130
S10K130
S14K130
S20K130
130
130
130
130
130
170
170
170
170
170
400
1200
2500
4500
8000
4.2
9.5
19.0
34.0
74.0
0.10
0.25
0.40
0.60
1.00
B72205S0141K101
B72207S0141K101
B72210S0141K101
B72214S0141K101
B72220S0141K101
S05K140
S07K140
S10K140
S14K140
S20K140
140
140
140
140
140
180
180
180
180
180
400
1200
2500
4500
8000
4.5
10.0
22.0
36.0
78.0
0.10
0.25
0.40
0.60
1.00
B72205S0151K101
B72207S0151K101
B72210S0151K101
B72214S0151K101
B72220S0151K101
S05K150
S07K150
S10K150
S14K150
S20K150
150
150
150
150
150
200
200
200
200
200
400
1200
2500
4500
8000
4.9
11.0
24.0
40.0
85.0
0.10
0.25
0.40
0.60
1.00
B72205S0171K101
B72207S0171K101
B72210S0171K101
B72214S0171K101
B72220S0171K101
S05K175
S07K175
S10K175
S14K175
S20K175
175
175
175
175
175
225
225
225
225
225
400
1200
2500
4500
8000
5.6
13.0
28.0
46.0
98.0
0.10
0.25
0.40
0.60
1.00
B72205S0231K101
B72207S0231K101
B72210S0231K101
B72214S0231K101
B72220S0231K101
S05K230
S07K230
S10K230
S14K230
S20K230
230
230
230
230
230
300
300
300
300
300
400
1200
2500
4500
8000
7.2
17.0
36.0
60.0
130.0
0.10
0.25
0.40
0.60
1.00
B72205S0251K101
B72207S0251K101
B72210S0251K101
B72214S0251K101
B72220S0251K101
S05K250
S07K250
S10K250
S14K250
S20K250
250
250
250
250
250
320
320
320
320
320
400
1200
2500
4500
8000
8.2
19.0
38.0
65.0
140.0
0.10
0.25
0.40
0.60
1.00
Ordering code
Please read Cautions and warnings and
Important notes at the end of this document.
7
11/07
imax
Wmax
(8/20 µs) (2 ms)
A
J
400
3.6
1200
8.4
2500
18.0
4500
30.0
6500
60.0
Pmax
W
0.10
0.25
0.40
0.60
1.00
Leaded varistors
StandarD series
Characteristics (TA = 25 °C)
∆Vv
(1 mA)
%
±10
±10
±10
±10
±10
vc, max
(ic)
V
300
300
300
300
300
ic
B72205S0111K101
B72207S0111K101
B72210S0111K101
B72214S0111K101
B72220S0111K101
Vv
(1 mA)
V
180
180
180
180
180
5.0
10.0
25.0
50.0
100.0
Ctyp
(1 kHz)
pF
110
220
445
730
1520
B72205S0131K101
B72207S0131K101
B72210S0131K101
B72214S0131K101
B72220S0131K101
205
205
205
205
205
±10
±10
±10
±10
±10
340
340
340
340
340
5.0
10.0
25.0
50.0
100.0
100
200
400
650
1340
B72205S0141K101
B72207S0141K101
B72210S0141K101
B72214S0141K101
B72220S0141K101
220
220
220
220
220
±10
±10
±10
±10
±10
360
360
360
360
360
5.0
10.0
25.0
50.0
100.0
95
180
370
610
1240
B72205S0151K101
B72207S0151K101
B72210S0151K101
B72214S0151K101
B72220S0151K101
240
240
240
240
240
±10
±10
±10
±10
±10
395
395
395
395
395
5.0
10.0
25.0
50.0
100.0
90
170
350
570
1160
B72205S0171K101
B72207S0171K101
B72210S0171K101
B72214S0171K101
B72220S0171K101
270
270
270
270
270
±10
±10
±10
±10
±10
455
455
455
455
455
5.0
10.0
25.0
50.0
100.0
75
150
300
490
1000
B72205S0231K101
B72207S0231K101
B72210S0231K101
B72214S0231K101
B72220S0231K101
360
360
360
360
360
±10
±10
±10
±10
±10
595
595
595
595
595
5.0
10.0
25.0
50.0
100.0
60
115
230
380
760
B72205S0251K101
B72207S0251K101
B72210S0251K101
B72214S0251K101
B72220S0251K101
390
390
390
390
390
±10
±10
±10
±10
±10
650
650
650
650
650
5.0
10.0
25.0
50.0
100.0
55
105
215
350
700
Ordering code
Please read Cautions and warnings and
Important notes at the end of this document.
8
11/07
A
Leaded varistors
StandarD series
Maximum ratings (TA = 85 °C)
VRMS
VDC
B72205S0271K101
B72207S0271K101
B72210S0271K101
B72214S0271K101
B72220S0271K101
Type
(untaped)
SIOVS05K275
S07K275
S10K275
S14K275
S20K275
Wmax
(2 ms)
J
8.6
21.0
43.0
71.0
151.0
Pmax
V
350
350
350
350
350
imax
(8/20 µs)
A
400
1200
2500
4500
8000
V
275
275
275
275
275
B72205S0301K101
B72207S0301K101
B72210S0301K101
B72214S0301K101
B72220S0301K101
S05K300
S07K300
S10K300
S14K300
S20K300
300
300
300
300
300
385
385
385
385
385
400
1200
2500
4500
8000
9.6
23.0
47.0
76.0
173.0
0.10
0.25
0.40
0.60
1.00
B72210S0321K101
B72214S0321K101
B72220S0321K101
S10K320
S14K320
S20K320
320
320
320
420
420
420
2500
4500
8000
50.0
84.0
184.0
0.40
0.60
1.00
B72205S0381K101
B72207S0381K101
B72210S0381K101
B72214S0381K101
B72220S0381K101
S05K385
S07K385
S10K385
S14K385
S20K385
385
385
385
385
385
505
505
505
505
505
400
1200
2500
4500
8000
13.0
28.0
40.0
80.0
150.0
0.10
0.25
0.40
0.60
1.00
B72205S0421K101
B72207S0421K101
B72210S0421K101
B72214S0421K101
B72220S0421K101
S05K420
S07K420
S10K420
S14K420
S20K420
420
420
420
420
420
560
560
560
560
560
400
1200
2500
4500
8000
14.0
32.0
45.0
90.0
175.0
0.10
0.25
0.40
0.60
1.00
B72205S0441K101
B72207S0441K101
B72210S0441K101
B72214S0441K101
B72220S0441K101
S05K440
S07K440
S10K440
S14K440
S20K440
440
440
440
440
440
585
585
585
585
585
400
1200
2500
4500
8000
16.0
34.0
47.0
95.0
185.0
0.10
0.25
0.40
0.60
1.00
B72205S0461K101
B72207S0461K101
B72210S0461K101
B72214S0461K101
B72220S0461K101
S05K460
S07K460
S10K460
S14K460
S20K460
460
460
460
460
460
615
615
615
615
615
400
1200
2500
4500
8000
18.0
36.0
50.0
100.0
195.0
0.10
0.25
0.40
0.60
1.00
Ordering code
Please read Cautions and warnings and
Important notes at the end of this document.
9
11/07
W
0.10
0.25
0.40
0.60
1.00
Leaded varistors
StandarD series
Characteristics (TA = 25 °C)
B72205S0271K101
B72207S0271K101
B72210S0271K101
B72214S0271K101
B72220S0271K101
Vv
(1 mA)
V
430
430
430
430
430
∆Vv
(1 mA)
%
±10
±10
±10
±10
±10
B72205S0301K101
B72207S0301K101
B72210S0301K101
B72214S0301K101
B72220S0301K101
470
470
470
470
470
±10
±10
±10
±10
±10
B72210S0321K101
B72214S0321K101
B72220S0321K101
510
510
510
B72205S0381K101
B72207S0381K101
B72210S0381K101
B72214S0381K101
B72220S0381K101
5.0
10.0
25.0
50.0
100.0
Ctyp
(1 kHz)
pF
50
95
195
320
630
775
775
775
775
775
5.0
10.0
25.0
50.0
100.0
45
90
180
300
580
±10
±10
±10
840
840
840
25.0
50.0
100.0
170
280
540
620
620
620
620
620
±10
±10
±10
±10
±10
1025
1025
1025
1025
1025
5.0
10.0
25.0
50.0
100.0
40
75
150
240
450
B72205S0421K101
B72207S0421K101
B72210S0421K101
B72214S0421K101
B72220S0421K101
680
680
680
680
680
±10
±10
±10
±10
±10
1120
1120
1120
1120
1120
5.0
10.0
25.0
50.0
100.0
35
65
135
220
420
B72205S0441K101
B72207S0441K101
B72210S0441K101
B72214S0441K101
B72220S0441K101
715
715
715
715
715
±10
±10
±10
±10
±10
1180
1180
1180
1180
1180
5.0
10.0
25.0
50.0
100.0
32
60
125
210
400
B72205S0461K101
B72207S0461K101
B72210S0461K101
B72214S0461K101
B72220S0461K101
750
750
750
750
750
±10
±10
±10
±10
±10
1240
1240
1240
1240
1240
5.0
10.0
25.0
50.0
100.0
30
55
120
200
380
Ordering code
Please read Cautions and warnings and
Important notes at the end of this document.
vc, max
(ic)
V
710
710
710
710
710
10
11/07
ic
A
Leaded varistors
StandarD series
Maximum ratings (TA = 85 °C)
VRMS
VDC
B72210S0511K101
B72214S0511K101
B72220S0511K101
Type
(untaped)
SIOVS10K510
S14K510
S20K510
V
510
510
510
V
670
670
670
B72210S0551K101
B72214S0551K101
B72220S0551K101
S10K550
S14K550
S20K550
550
550
550
B72210S0621K101
B72214S0621K101
B72220S0621K101
S10K625
S14K625
S20K625
B72210S0681K101
B72214S0681K101
B72220S0681K101
S10K680
S14K680
S20K680
B72214S0102K101
B72220S0102K101
S14K10001)
S20K10001)
Ordering code
imax
(8/20 µs)
A
2500
4500
6500
Wmax
(2 ms)
J
55.0
110.0
190.0
Pmax
745
745
745
2500
4500
6500
60.0
120.0
210.0
0.40
0.60
1.00
625
625
625
825
825
825
2500
4500
6500
68.0
130.0
230.0
0.40
0.60
1.00
680
680
680
895
895
895
2500
4500
6500
72.0
140.0
250.0
0.40
0.60
1.00
1100
1100
1465
1465
4500
6500
230.0
410.0
0.60
1.00
1) Operating voltage differs from type designation.
Please read Cautions and warnings and
Important notes at the end of this document.
11
11/07
W
0.40
0.60
1.00
Leaded varistors
StandarD series
Characteristics (TA = 25 °C)
Ordering code
∆Vv
(1 mA)
%
±10
±10
±10
vc, max
(ic)
V
1355
1355
1355
ic
A
25.0
50.0
100.0
Ctyp
(1 kHz)
pF
110
180
340
B72210S0511K101
B72214S0511K101
B72220S0511K101
Vv
(1 mA)
V
820
820
820
B72210S0551K101
B72214S0551K101
B72220S0551K101
910
910
910
±10
±10
±10
1500
1500
1500
25.0
50.0
100.0
105
170
320
B72210S0621K101
B72214S0621K101
B72220S0621K101
1000
1000
1000
±10
±10
±10
1650
1650
1650
25.0
50.0
100.0
90
150
280
B72210S0681K101
B72214S0681K101
B72220S0681K101
1100
1100
1100
±10
±10
±10
1815
1815
1815
25.0
50.0
100.0
85
140
250
B72214S0102K101
B72220S0102K101
1800
1800
±10
±10
2970
2970
50.0
100.0
100
170
Please read Cautions and warnings and
Important notes at the end of this document.
12
11/07
Leaded varistors
StandarD series
Dimensional drawing
s
Nominal diameter
mm
5
7
10
14
20
3 max.
h
b
Weight
1)
a
Bottom view
VRMS
V
11 … 460
11 … 460
11 … 680
11 … 1000
11 … 1000
Weight
g
0.3 … 0.7
0.4 … 1.1
1.0 … 3.0
1.4 … 7.6
2.7 … 15.7
The weight of varistors in between these
voltage classes can be interpolated.
e
a
ød
e
1) Seating plane to IEC 60717
VAR0408-C
Dimensions
±1
bmax
mm
7.0
9.0
12.0
15.5
21.5
smax
mm
3.3
3.4
4.0
4.0
4.5
hmax
mm
8.5
11.0
14.5
18.5
25.5
Imin
mm
25.0
25.0
25.0
25.0
25.0
d ±0.05
mm
0.6
0.6
0.8
0.8
1.0
B72205S0110K101
B72207S0110K101
B72210S0110K101
B72214S0110K101
B72220S0110K101
mm
5.0
5.0
7.5
7.5
10.0
a ±1
mm
1.2
1.2
1.4
1.4
1.5
B72205S0140K101
B72207S0140K101
B72210S0140K101
B72214S0140K101
B72220S0140K101
5.0
5.0
7.5
7.5
10.0
1.3
1.3
1.5
1.5
1.6
7.0
9.0
12.0
15.5
21.5
3.4
3.5
4.2
4.2
4.6
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
B72205S0170K101
B72207S0170K101
B72210S0170K101
B72214S0170K101
B72220S0170K101
5.0
5.0
7.5
7.5
10.0
1.4
1.4
1.6
1.7
1.8
7.0
9.0
12.0
15.5
21.5
3.5
3.6
4.4
4.4
4.8
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
B72205S0200K101
B72207S0200K101
B72210S0200K101
B72214S0200K101
B72220S0200K101
5.0
5.0
7.5
7.5
10.0
1.2
1.2
1.8
1.9
2.1
7.0
9.0
12.0
15.5
21.5
3.5
3.6
4.5
4.6
5.1
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
Ordering code
Please read Cautions and warnings and
Important notes at the end of this document.
13
11/07
Leaded varistors
StandarD series
Dimensions
B72205S0250K101
B72207S0250K101
B72210S0250K101
B72214S0250K101
B72220S0250K101
mm
5.0
5.0
7.5
7.5
10.0
a ±1
mm
1.3
1.3
1.6
1.7
1.8
bmax
mm
7.0
9.0
12.0
15.5
21.5
smax
mm
3.6
3.7
4.2
4.2
4.7
hmax
mm
8.5
11.0
14.5
18.5
25.5
Imin
mm
25.0
25.0
25.0
25.0
25.0
d ±0.05
mm
0.6
0.6
0.8
0.8
1.0
B72205S0300K101
B72207S0300K101
B72210S0300K101
B72214S0300K101
B72220S0300K101
5.0
5.0
7.5
7.5
10.0
1.5
1.5
1.7
1.8
2.0
7.0
9.0
12.0
15.5
21.5
3.6
3.7
4.4
4.4
4.9
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
B72205S0350K101
B72207S0350K101
B72210S0350K101
B72214S0350K101
B72220S0350K101
5.0
5.0
7.5
7.5
10.0
1.6
1.6
1.8
2.0
2.2
7.0
9.0
12.0
15.5
21.5
3.7
3.9
4.4
4.5
5.1
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
B72205S0400K101
B72207S0400K101
B72210S0400K101
B72214S0400K101
B72220S0400K101
5.0
5.0
7.5
7.5
10.0
1.8
1.8
2.1
2.2
2.4
7.0
9.0
12.0
15.5
21.5
3.9
4.1
4.8
4.9
5.4
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
B72205S0500K101
B72207S0500K101
B72210S0500K101
B72214S0500K101
B72220S0500K101
5.0
5.0
7.5
7.5
10.0
1.2
1.2
1.4
1.4
1.5
7.0
9.0
12.0
15.5
21.5
3.3
3.3
3.9
3.9
4.3
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
B72205S0600K101
B72207S0600K101
B72210S0600K101
B72214S0600K101
B72220S0600K101
5.0
5.0
7.5
7.5
10.0
1.2
1.2
1.4
1.5
1.6
7.0
9.0
12.0
15.5
21.5
3.3
3.3
4.0
4.0
4.4
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
B72205S0750K101
B72207S0750K101
B72210S0750K101
B72214S0750K101
B72220S0750K101
5.0
5.0
7.5
7.5
10.0
1.3
1.3
1.5
1.5
1.6
7.0
9.0
12.0
15.5
21.5
3.4
3.6
4.2
4.2
4.6
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
±1
Ordering code
Please read Cautions and warnings and
Important notes at the end of this document.
14
11/07
Leaded varistors
StandarD series
Dimensions
B72205S0950K101
B72207S0950K101
B72210S0950K101
B72214S0950K101
B72220S0950K101
mm
5.0
5.0
7.5
7.5
10.0
a ±1
mm
1.3
1.3
1.5
1.5
1.6
bmax
mm
7.0
9.0
12.0
15.5
21.5
smax
mm
3.4
3.4
4.0
4.0
4.5
hmax
mm
8.5
11.0
14.5
18.5
25.5
Imin
mm
25.0
25.0
25.0
25.0
25.0
d ±0.05
mm
0.6
0.6
0.8
0.8
1.0
B72205S0111K101
B72207S0111K101
B72210S0111K101
B72214S0111K101
B72220S0111K101
5.0
5.0
7.5
7.5
10.0
1.5
1.5
1.6
1.7
1.8
7.0
9.0
12.0
15.5
21.5
3.6
3.6
4.2
4.2
4.6
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
B72205S0131K101
B72207S0131K101
B72210S0131K101
B72214S0131K101
B72220S0131K101
5.0
5.0
7.5
7.5
10.0
1.6
1.6
1.8
1.9
2.0
7.0
9.0
12.0
15.5
21.5
3.6
3.6
4.2
4.2
4.7
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
B72205S0141K101
B72207S0141K101
B72210S0141K101
B72214S0141K101
B72220S0141K101
5.0
5.0
7.5
7.5
10.0
1.7
1.7
1.9
2.0
2.1
7.0
9.0
12.0
15.5
21.5
3.7
3.7
4.3
4.3
4.8
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
B72205S0151K101
B72207S0151K101
B72210S0151K101
B72214S0151K101
B72220S0151K101
5.0
5.0
7.5
7.5
10.0
1.8
1.8
2.0
2.1
2.2
7.0
9.0
12.0
15.5
21.5
3.8
3.8
4.4
4.4
4.9
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
B72205S0171K101
B72207S0171K101
B72210S0171K101
B72214S0171K101
B72220S0171K101
5.0
5.0
7.5
7.5
10.0
2.0
2.0
2.2
2.2
2.3
7.0
9.0
12.0
15.5
21.5
3.9
4.0
4.6
4.6
5.0
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
B72205S0231K101
B72207S0231K101
B72210S0231K101
B72214S0231K101
B72220S0231K101
5.0
5.0
7.5
7.5
10.0
1.8
1.8
2.0
2.0
2.1
7.0
9.0
12.0
15.5
21.5
4.0
4.0
4.7
4.7
5.1
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
±1
Ordering code
Please read Cautions and warnings and
Important notes at the end of this document.
15
11/07
Leaded varistors
StandarD series
Dimensions
B72205S0251K101
B72207S0251K101
B72210S0251K101
B72214S0251K101
B72220S0251K101
mm
5.0
5.0
7.5
7.5
10.0
a ±1
mm
1.8
1.8
2.0
2.0
2.2
bmax
mm
7.0
9.0
12.0
15.5
21.5
smax
mm
4.2
4.2
4.8
4.8
5.3
hmax
mm
8.5
11.0
14.5
18.5
25.5
Imin
mm
25.0
25.0
25.0
25.0
25.0
d ±0.05
mm
0.6
0.6
0.8
0.8
1.0
B72205S0271K101
B72207S0271K101
B72210S0271K101
B72214S0271K101
B72220S0271K101
5.0
5.0
7.5
7.5
10.0
2.0
2.0
2.2
2.2
2.3
7.0
9.0
12.0
15.5
21.5
4.3
4.4
5.0
5.0
5.4
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
B72205S0301K101
B72207S0301K101
B72210S0301K101
B72214S0301K101
B72220S0301K101
5.0
5.0
7.5
7.5
10.0
2.1
2.1
2.3
2.3
2.4
7.0
9.0
12.0
15.5
21.5
4.5
4.5
5.1
5.2
5.6
8.5
11.0
14.5
18.5
25.5
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
B72210S0321K101
B72214S0321K101
B72220S0321K101
7.5
7.5
10.0
2.4
2.4
2.6
12.0
15.5
21.5
5.4
5.4
5.8
15.0
19.0
25.5
25.0
25.0
25.0
0.8
0.8
1.0
B72205S0381K101
B72207S0381K101
B72210S0381K101
B72214S0381K101
B72220S0381K101
5.0
5.0
7.5
7.5
10.0
2.5
2.5
2.7
2.7
2.8
7.0
9.0
12.0
15.5
21.5
5.1
5.2
5.8
5.9
6.3
9.0
11.5
15.0
19.0
26.0
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
B72205S0421K101
B72207S0421K101
B72210S0421K101
B72214S0421K101
B72220S0421K101
5.0
5.0
7.5
7.5
10.0
2.8
2.8
2.9
2.9
3.1
7.0
9.0
12.0
15.5
21.5
5.4
5.4
6.1
6.1
6.5
9.0
11.5
15.0
19.0
26.0
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
B72205S0441K101
B72207S0441K101
B72210S0441K101
B72214S0441K101
B72220S0441K101
5.0
5.0
7.5
7.5
10.0
2.8
2.8
3.0
3.0
3.1
7.0
9.0
12.0
15.5
21.5
5.5
5.5
6.2
6.3
6.7
9.0
11.5
15.0
19.0
26.0
25.0
25.0
25.0
25.0
25.0
0.6
0.6
0.8
0.8
1.0
±1
Ordering code
Please read Cautions and warnings and
Important notes at the end of this document.
16
11/07
Leaded varistors
StandarD series
Dimensions
B72205S0461K101
B72207S0461K101
B72210S0461K101
B72214S0461K101
B72220S0461K101
mm
5.0
5.0
7.5
7.5
10.0
a ±1
mm
3.0
3.0
3.1
3.1
3.3
bmax
mm
7.0
9.0
12.0
15.5
21.5
smax
mm
5.7
5.7
6.3
6.4
6.8
hmax
mm
9.0
11.5
15.0
19.0
26.0
Imin
mm
25.0
25.0
25.0
25.0
25.0
d ±0.05
mm
0.6
0.6
0.8
0.8
1.0
B72210S0511K101
B72214S0511K101
B72220S0511K101
7.5
7.5
10.0
3.4
3.4
3.5
12.0
15.5
21.5
6.7
6.8
7.1
15.0
19.0
26.0
25.0
25.0
25.0
0.8
0.8
1.0
B72210S0551K101
B72214S0551K101
B72220S0551K101
7.5
7.5
10.0
3.7
3.7
3.9
12.0
15.5
21.5
7.1
7.2
7.5
15.0
19.0
26.0
25.0
25.0
25.0
0.8
0.8
1.0
B72210S0621K101
B72214S0621K101
B72220S0621K101
7.5
7.5
10.0
4.0
4.0
4.2
12.0
15.5
21.5
7.5
7.5
7.9
15.0
19.0
26.0
25.0
25.0
25.0
0.8
0.8
1.0
B72210S0681K101
B72214S0681K101
B72220S0681K101
7.5
7.5
10.0
4.4
4.4
4.5
12.0
15.5
21.5
7.9
8.0
8.4
15.0
19.0
26.0
25.0
25.0
25.0
0.8
0.8
1.0
B72214S0102K101
B72220S0102K101
7.5
10.0
6.7
6.9
15.5
21.5
11.0
11.4
20.5
28.5
25.0
25.0
0.8
1.0
±1
Ordering code
Please read Cautions and warnings and
Important notes at the end of this document.
17
11/07
Leaded varistors
StandarD series
Reliability data
Test
Test methods/conditions
Varistor voltage
The voltage between two terminals with To meet the specified value.
the specified measuring current applied
is called Vv (1 mADC @ 0.2 … 2 s).
The maximum voltage between two
To meet the specified value.
terminals with the specified standard
impulse current (8/20 µs) applied.
CECC 42 000, test 4.20
|∆V/V (1 mA)| ≤10%
1000 h at UCT
Clamping voltage
Max. AC operating voltage
Surge current derating,
8/20 µs
Surge current derating,
2 ms
Electric strength
After having continuously applied
the maximum allowable voltage at UCT
±2 °C for 1000 h, the specimen shall be
stored at room temperature and normal
humidity for 1 to 2 h.
Thereafter, the change of Vv shall be
measured.
CECC 42 000, test C 2.1
Requirement
|∆V/V (1 mA)| ≤10%
100 surge currents (8/20 µs), unipolar, (measured in direction
interval 30 s, amplitude corresponding of surge current)
to derating curve for 100 impulses at
No visible damage
20 µs
CECC 42 000, test C 2.1
|∆V/V (1 mA)| ≤10%
100 surge currents (2 ms), unipolar,
interval 120 s, amplitude corresponding
to derating curve for 100 impulses at
2 ms
CECC 42 000, test 4.7
(measured in direction
of surge current)
Metal balls method, 2500 VRMS, 60 s
The varistor is placed in a container
holding 1.6 ±0.2 mm diameter metal
balls such that only the terminations of
the varistor are protruding.
The specified voltage shall be applied
between both terminals of the specimen connected together and the electrode inserted between the metal balls.
Please read Cautions and warnings and
Important notes at the end of this document.
18
11/07
No visible damage
No breakdown
Leaded varistors
StandarD series
Reliability data
Test
Test methods/conditions
Requirement
Climatic sequence
CECC 42 000, test 4.16
|∆V/V (1 mA)| ≤10%
Fast temperature cycling
Damp heat, steady state
Solderability
The specimen shall be subjected to:
Rins ≥1 MΩ
a) dry heat at UCT, 16 h
b) damp heat, 1st cycle:
55 °C, 93% r. H., 24 h
c) cold, LCT, 2 h
d) damp heat, additional 5 cycles:
55 °C/25 °C, 93% r. H., 24 h/cycle.
Then the specimen shall be stored at
room temperature and normal humidity
for 1 to 2 h.
Thereafter, the change of Vv shall be
measured. Thereafter, insulation resistance Rins shall be measured according
to CECC 42 000, test 4.8 at V = 500 V.
IEC 60068-2-14, test Na, LCT/UCT,
|∆V/V (1 mA)| ≤5%
dwell time 30 min, 5 cycles
No visible damage
The specimen shall be subjected to
|∆V/V (1 mA)| ≤10%
40 ±2 °C, 90 to 95% r. H. for 56 days R ≥1 MΩ
ins
without load / with 10% of the maximum
continuous DC operating voltage VDC.
Then stored at room temperature and
normal humidity for 1 to 2 h.
Thereafter, the change of Vv shall be
measured. Thereafter, insulation resistance Rins shall be measured according
to CECC 42 000, test 4.8 at V = 500 V.
IEC 60068-2-20, test Ta,
The inspection shall be
method 1 with modified conditions for carried out under adequate
lead-free solder alloys: 245 °C, 3 s:
light with normal eyesight or
with the assistance of a
After dipping the terminals to a depth
of approximately 3 mm from the body magnifier capable of giving
in a soldering bath of 245 °C for 3 s, the a magnification of 4 to
10 times. The dipped surterminals shall be visually examined.
face shall be covered with
a smooth and bright solder
coating with no more than
small amounts of scattered
imperfections such as
pinholes or un-wetted or
de-wetted areas. These
imperfections shall not be
concentrated in one area.
Please read Cautions and warnings and
Important notes at the end of this document.
19
11/07
Leaded varistors
StandarD series
Reliability data
Test
Test methods/conditions
Resistance to soldering heat IEC 60068-2-20, test Tb, method 1A,
260 °C, 10 s:
Tensile strength
|∆V/V (1 mA)| ≤5%
No visible damage
Each lead shall be dipped into a solder
bath having a temperature of 260 ±5 °C
to a point 2.0 to 2.5 mm from the body of
the specimen, be held there for 10 ±1 s
and then be stored at room temperature
and normal humidity for 1 to 2 h.
The change of Vv shall be measured
and the specimen shall be visually
examined.
IEC 60068-2-21, test Ua1
|∆V/V (1 mA)| ≤5%
After gradually applying the force
specified below and keeping the unit
fixed for 10 s, the terminal shall be
visually examined for any damage.
Vibration
Requirement
Force for wire diameter:
0.6 mm = 10 N
0.8 mm = 10 N
1.0 mm = 20 N
IEC 60068-2, test Fc
No break of solder joint,
no wire break
|∆V/V (1 mA)| ≤5%
Frequency range: 10 … 55 Hz
Amplitude:
0.75 mm or 98 m/s2
Duration:
6 h (3 · 2 h)
Pulse:
sine wave
After repeatedly applying a single
harmonic vibration according to the
table above.
The change of Vv shall be measured
and the specimen shall be visually
examined.
No visible damage
Bump
IEC 60068-2-29, test Eb
|∆V/V (1 mA)| ≤5%
No visible damage
Flammability
Pulse duration:
6 ms
Max. acceleration: 400 m/s2
Number of bumps: 4000
Pulse:
half sine
IEC 60695-2-2 (needle flame test)
5 s max.
Severity: vertical 10 s
Note:
UCT = Upper category temperature / LCT = Lower category temperature / Rins = Insulation resistance to CECC 42 000, test 4.8
Please read Cautions and warnings and
Important notes at the end of this document.
20
11/07
Leaded varistors
StandarD series
v/i characteristics
v = f (i) – for explanation of the characteristics refer
to “General technical information”, 1.6.3
v
A = Leakage current
B = Protection level
for worst-case
varistor tolerances
VAR0458-L
6000
V
4000
B
A
2000
K420
K460
1000
800 K420
K385
K440
600 K460
400 K385
K300
K250
K275
K230
200 K175
K140
K115
100
80 K75
60
40
K440
K275
K230
K150
K130
K175
K140
K115
K150
K130
K95
K95
K60
K50
K60
K50
K40
K35
K30
K25
K20
K17
K14
20
K300
K250
K75
K40
K35
K30
K25
K20
K17
K14
K11
K11
10
8
6
4
2
1 _
10 5
10
_4
10
_3
10
_2
10
_1
10 0
10 1
10 2
A 10 3
i
SIOV-S05 …
Please read Cautions and warnings and
Important notes at the end of this document.
21
11/07
Leaded varistors
StandarD series
v/i characteristics
v = f (i) – for explanation of the characteristics refer
to “General technical information”, 1.6.3
v
A = Leakage current
B = Protection level
for worst-case
varistor tolerances
VAR0443-Q
6000
V
4000
B
A
2000
K420
1000
800 K420
K460
K440
600 K460
400 K385
K300
K250
200
K440
K275
K230
K175
K140
K115
K150
K130
K385
K300
K250
K275
K230
K150
K130
K175
K140
K115
K95
K75
K60
100 K95
80
K60
60
K75
K50
K50
K40
K35
K30
K25
K40
K35
K20
K17
K30
K25
K14
K11
20 K20
K17
K14
K11
40
10
8
6
4
2
1 _
10 5
10
_4
10
_3
10
_2
10
_1
10 0
10 1
10 2
10 3
A 10 4
i
SIOV-S07 …
Please read Cautions and warnings and
Important notes at the end of this document.
22
11/07
Leaded varistors
StandarD series
v/i characteristics
v = f (i) – for explanation of the characteristics refer
to “General technical information”, 1.6.3
A = Leakage current
B = Protection level
VAR0451-H
10000
V
v
for worst-case
varistor tolerances
B
A
6000
4000
460
440
2000
680
625
1000
680
550
460
420
800
625
600 510
400
385
320
275
230
440
175
150
130
95
95
60
60
60
50
40
35
30
25
20
17
14
40
20
140
115
75
100
75
320
275
230
300
250
150
130
80
420
385
300
250
200 175
140
115
550
510
50
40
35
30
25
20
17
14
11
11
10
8
6
4 _
10 5
10
_4
10
_3
10
_2
10
_1
10 0
10 1
10 2
10 3
i
SIOV-S10 …
Please read Cautions and warnings and
Important notes at the end of this document.
23
11/07
A 10 4
Leaded varistors
StandarD series
v/i characteristics
v = f (i) – for explanation of the characteristics refer
to “General technical information”, 1.6.3
A = Leakage current
B = Protection level
VAR0459-T
10000
V
v
for worst-case
varistor tolerances
B
A
6000
4000
1000
2000
440
1000
1000
800 680
550
600 460
625
510
420
385
320
300
250
275
230
150
130
175
140
115
400
200
100
80
420
95
50
40
35
30
25
20
17
14
11
625
550
460
510
385
440
320
275
230
300
250
175
140
115
150
130
95
75
60
50
75
60
680
40
35
30
25
20
60
40
20
17
14
11
10
8
6
4 _
10 5
10
_4
10
_3
10
_2
10
_1
10 0
10 1
10 2
10 3
i
SIOV-S14 …
Please read Cautions and warnings and
Important notes at the end of this document.
24
11/07
A 10 4
Leaded varistors
StandarD series
v/i characteristics
v = f (i) – for explanation of the characteristics refer
to “General technical information”, 1.6.3
A = Leakage current
B = Protection level
VAR0444-Y
10000
V
v
for worst-case
varistor tolerances
B
A
6000
4000
1000
2000
1000
1000
625
510
440
385
800 680
550
600
460
420
400
320
275
230
300
250
150
130
200 175
140
115
60
40
20
75
40
35
30
25
20
17
14
320
275
230
300
250
175
140
115
150
130
95
60
60
50
625
510
440
385
75
95
100
80
680
550
460
420
50
40
35
30
25
20
17
14
11
11
10
8
6
4 _
10 5
10
_4
10
_3
10
_2
10
_1
10 0
10 1
10 2
10 3
10 4 A 10 5
i
SIOV-S20 …
Please read Cautions and warnings and
Important notes at the end of this document.
25
11/07
Leaded varistors
StandarD series
Derating curves
Maximum surge current imax = f (tr, pulse train)
For explanation of the derating curves refer to “General technical information”, section 1.8.1
VAR0097-E
10 3
i max A
i max
tr
10 2
5
1x
10 1
5
10
2
10 3 10
10 5 10 4
10 6
10 0
5
10
5
10
2
_1
_2
10 1
5
10 2
5
10 3
5
µs 10 4
tr
SIOV-S05K11 … K40
VAR0098-M
10 3
i max A
i max
tr
10 2
5
1x
10
10 1
5
2
2
10 3 10
4
5
10 10
10 6
10 0
5
10
5
10
_1
_2
10 1
5
10 2
5
10 3
5
µs 10 4
tr
SIOV-S05K50 … K460
Please read Cautions and warnings and
Important notes at the end of this document.
26
11/07
Leaded varistors
StandarD series
Derating curves
Maximum surge current imax = f (tr, pulse train)
For explanation of the derating curves refer to “General technical information”, section 1.8.1
VAR0018-Z
10 3
i max A
i max
tr
10 2
1x
5
2
10
10 1
10 3 10 2
10 5 10 4
5
10 6
10 0
5
10
_1
10 1
5
10 2
5
10 3
5
µs 10 4
tr
SIOV-S07K11 … K40
VAR0099-V
10 4
i max A
i max
tr
10 3
5
1x
10
5
2
10
2
10 3 10 2
10 5 10 4
10 6
10 1
5
10 0
5
10
_1
10 1
5
10 2
5
10 3
5
µs 10 4
tr
SIOV-S07K50 … K460
Please read Cautions and warnings and
Important notes at the end of this document.
27
11/07
Leaded varistors
StandarD series
Derating curves
Maximum surge current imax = f (tr, pulse train)
For explanation of the derating curves refer to “General technical information”, section 1.8.1
VAR0100-3
10 3
i max A
1x
10 2
5
i max
tr
10 2
2
10 3 10
4
10 5 10
10 6
10 1
5
10 0
5
10
5
10
_1
_2
10 1
5
10 2
5
10 3
5
µs 10 4
tr
SIOV-S10K11 … K40
VAR0101-B
10 4
i max A
i max
tr
10 3
5
1x
10
10 2
5
2
10 3 10 2
10 5 10 4
10 6
10 1
5
10 0
5
10
_1
10 1
5
10 2
5
10 3
5
µs 10 4
tr
SIOV-S10K50 … K320
Please read Cautions and warnings and
Important notes at the end of this document.
28
11/07
Leaded varistors
StandarD series
Derating curves
Maximum surge current imax = f (tr, pulse train)
For explanation of the derating curves refer to “General technical information”, section 1.8.1
VAR0102-J
10 4
i max A
i max
tr
10 3
5
1x
10
10 2
5
2
2
10 3 10
10 5 10 4
10 6
10 1
5
10 0
5
10
_1
10 1
5
10 2
5
10 3
5
µs 10 4
tr
SIOV-S10K385 … K680
VAR0103-S
10 4
i max A
i max
tr
10 3
5
1x
10 2
5
10
5
10
2
2
10 3 10
4
10 5 10
10 6
1
10 0
5
10
_1
10 1
5
10 2
5
10 3
5
µs 10 4
tr
SIOV-S14K11 … K40
Please read Cautions and warnings and
Important notes at the end of this document.
29
11/07
Leaded varistors
StandarD series
Derating curves
Maximum surge current imax = f (tr, pulse train)
For explanation of the derating curves refer to “General technical information”, section 1.8.1
VAR0104-1
10 4
i max A
i max
tr
10 3
5
1x
2
10
10 2
5
10 3
10 2
4
10 5 10
10 6
10 1
5
10 0
5
10
_1
10 1
5
10 2
5
10 3
5
µs 10 4
tr
SIOV-S14K50 … K320
VAR0105-9
10 4
i max A
i max
tr
10 3
5
1x
2
10
10 2
5
2
10 3 10
4
10 5 10
10 6
10 1
5
10 0
5
10
_1
10 1
5
10 2
5
10 3
5
µs 10 4
tr
SIOV-S14K385 … K1000
Please read Cautions and warnings and
Important notes at the end of this document.
30
11/07
Leaded varistors
StandarD series
Derating curves
Maximum surge current imax = f (tr, pulse train)
For explanation of the derating curves refer to “General technical information”, section 1.8.1
VAR0106-H
10 4
i max A
i max
tr
10 3
5
1x
10
10 3
10 2
5
2
10 2
10 4
10 5
10 6
10 1
5
10 0
5
10
_1
10 1
5
10 2
5
10 3
5
µs 10 4
tr
SIOV-S20K11 … K40
VAR0107-Q
10 4
i max A
1x
10 3
5
10
5
2
10
5
1
2
10
10 3
10 5
i max
tr
10 2
10 4
10 6
10 0
5
10
_1
10 1
5
10 2
5
10 3
5
µs 10 4
tr
SIOV-S20K50 … K115
Please read Cautions and warnings and
Important notes at the end of this document.
31
11/07
Leaded varistors
StandarD series
Derating curves
Maximum surge current imax = f (tr, pulse train)
For explanation of the derating curves refer to “General technical information”, section 1.8.1
VAR0168-7
10 4
i max A
1x
10 3
5
2
10
10 3
10 2
5
10 5
i max
tr
10 2
10 4
10 6
10
5
1
10 0
5
10
_1
10 1
5
10 2
5
10 3
5
µs 10 4
tr
SIOV-S20K130 … K320
VAR0169-F
10 4
i max A
1x
10 3
5
10
5
2
10
10 3
2
10 5
i max
tr
10 2
10 4
10 6
10 1
5
10 0
5
10
_1
10 1
5
10 2
5
10 3
5
µs 10 4
tr
SIOV-S20K385 … K460
Please read Cautions and warnings and
Important notes at the end of this document.
32
11/07
Leaded varistors
StandarD series
Derating curves
Maximum surge current imax = f (tr, pulse train)
For explanation of the derating curves refer to “General technical information”, section 1.8.1
VAR0108-Y
10 4
i max A
10 3
5
1x
10 2
5
10 3
10
5
i max
tr
2
10
10 5
10 2
10 4
10 6
1
10 0
5
10
_1
10 1
5
10 2
5
10 3
5
µs 10 4
tr
SIOV-S20K510 … K1000
Please read Cautions and warnings and
Important notes at the end of this document.
33
11/07
Leaded varistors
StandarD series
Cautions and warnings
General
1. EPCOS metal oxide varistors (SIOVs) are designed for specific applications and should not be
used for purposes not identified in our specifications, application notes and data books unless
otherwise agreed with EPCOS during the design-in-phase.
2. Ensure suitability of SIOVs through reliability testing during the design-in phase. SIOVs should
be evaluated taking into consideration worst-case conditions.
3. For applications of SIOVs in line-to-ground circuits based on various international and local
standards there are restrictions existing or additional safety measures required.
Storage
1. Store SIOVs only in original packaging. Do not open the package before storage.
2. Storage conditions in original packaging:
Storage temperature:
Relative humidity:
Dew precipitation:
–25 °C … +45 °C
<75% annual average,
<95% on maximum 30 days a year.
Is to be avoided.
3. Avoid contamination of an SIOV’s surface during storage, handling and processing.
4. Avoid storage of SIOVs in harmful environments that can affect the function during long-term
operation (examples given under operation precautions).
5. The SIOV type series should be soldered within the time specified:
SIOV-S, -Q, -LS
ETFV and SFS types
24 months
12 months.
Handling
1. SIOVs must not be dropped.
2. Components must not be touched with bare hands. Gloves are recommended.
3. Avoid contamination of the surface of SIOV electrodes during handling, be careful of the sharp
edge of SIOV electrodes.
Soldering (where applicable)
1. Use rosin-type flux or non-activated flux.
2. Insufficient preheating may cause ceramic cracks.
3. Rapid cooling by dipping in solvent is not recommended.
4. Complete removal of flux is recommended.
Please read Cautions and warnings and
Important notes at the end of this document.
34
11/07
Leaded varistors
StandarD series
Mounting
1. Potting, sealing or adhesive compounds can produce chemical reactions in the SIOV ceramic
that will degrade the component’s electrical characteristics.
2. Overloading SIOVs may result in ruptured packages and expulsion of hot materials. For this reason SIOVs should be physically shielded from adjacent components.
Operation
1. Use SIOVs only within the specified temperature operating range.
2. Use SIOVs only within the specified voltage and current ranges.
3. Environmental conditions must not harm SIOVs. Use SIOVs only in normal atmospheric conditions. Avoid use in the presence of deoxidizing gases (chlorine gas, hydrogen sulfide gas,
ammonia gas, sulfuric acid gas, etc), corrosive agents, humid or salty conditions. Avoid contact
with any liquids and solvents.
Please read Cautions and warnings and
Important notes at the end of this document.
35
11/07
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As
a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic components
or failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in which
the malfunction or failure of a passive electronic component could endanger human life or health
(e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of
suitable design of the customer application or other action taken by the customer (e.g.
installation of protective circuitry or redundancy) that no injury or damage is sustained by third
parties in the event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the foregoing
for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version
of the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, DSSP, MiniBlue, MKK, MLSC,
MotorCap, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD,
SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered
or pending in Europe and in other countries. Further information will be found on the Internet at
www.epcos.com/trademarks.
36
11/07