Mean Well DRH-120-48 120w single output industrial din rail power supply Datasheet

120W Single Output Industrial DIN RAIL Power Supply
DR-120
series
Features :
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
UL 508(industrial control equipment)approved
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 55KHz
3 years warranty
SPECIFICATION
MODEL
OUTPUT
INPUT
DR-120-12
DR-120-24
DR-120-48
DC VOLTAGE
12V
24V
48V
RATED CURRENT
10A
5A
2.5A
CURRENT RANGE
0 ~ 10A
0 ~ 5A
0 ~ 2.5A
RATED POWER
120W
120W
120W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
100mVp-p
VOLTAGE ADJ. RANGE
24 ~ 28V
1.0%
48 ~ 53V
1.0%
12 ~ 14V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
1.0%
1.0%
SETUP, RISE TIME
500ms, 70ms/230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
36ms/230VAC
32ms/115VAC at full load
88 ~ 132VAC/176 ~ 264VAC by switch
248 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
80%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
2.6A/115VAC
LEAKAGE CURRENT
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND
VOLTAGE
SAFETY &
ISOLATION
RESISTANCE
EMC
(Note 4)
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
500ms, 70ms/115VAC at full load
84%
85%
1.6A/230VAC
COLD START 20A/115VAC
40A/230VAC
<3.5mA / 240VAC
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
29 ~ 33V
58 ~ 65V
15 ~ 16.5V
Protection type : Shut down o/p voltage, re-power on to recover
90
5 (TSW1)
90
5 (TSW1)
85
5 (TSW1)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
UL508, UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55011,EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
136.8Khrs min. MIL-HDBK-217F (25
65.5*125.2*100mm (W*H*D)
0.79Kg; 20pcs/16.5Kg/1.29CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:DR-120-SPEC 2011-06-17
DR-120
120W Single Output Industrial DIN RAIL Power Supply
Mechanical Specification
Case No. 921A
series
Unit:mm
100
125.2
+V ADJ.
230VAC
65.5
1
2
3
115VAC
TB1
TB2
1
2
3
4
LED
Terminal Pin No. Assignment (TB1)
35
Pin No.
1
2
3
ADMISSIBLE DIN-RAIL: TS35/7.5 OR TS35/15
Terminal Pin No. Assignment (TB2)
Pin No.
1,2
3,4
Block Diagram
fosc : 55KHz
RECTIFIERS
&
FILTER
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
DETECTION
CIRCUIT
FG
O.L.P.
O.T.P.
Derating Curve
PWM
CONTROL
O.V.P.
48V
OUTPUT VOLTAGE (V)
80
60
12V,24V
40
20
32
350
28
300
24
250
20
200
16
150
12
100
80
8
-10
0
10
20
30
45
50
AMBIENT TEMPERATURE ( )
60 (VERTICAL)
OUTPUT RIPPLE (mVp-p)
Static Characteristics (24V)
100
LOAD (%)
Assignment
DC OUTPUT +V
DC OUTPUT -V
230
115
EMI
FILTER
I/P
Assignment
FG
AC/N
AC/L
80
160
85
170
90
180
95
190
100
200
105
210
110
220
115
230
120
240
125
250
132
264
INPUT VOLTAGE (V) 60Hz
File Name:DR-120-SPEC 2011-06-17
Similar pages