MPM-15IS Series Board Mount, 15W Single, Dual & Triple Out AC/DC Power Supplies Key Features: • 15W Output Power • Universal 85-265 VAC Input • EN 60950 Approved (UL) • Meets IEC Safety Class II • Industry Standard Pin-Out • Single, Dual & Triple Outputs • Meets EN 55022 B • >250 kHour MTBF Chassis Mount Models & DIN Rail Mount Option Available! Electrical Specifications Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range Input Frequency Input Current Conditions Inrush Current EMI Min. Typ. Max. 85 265 47 440 See Model Selection Guide 115 VAC 15.0 230 VAC 30.0 Meets CISPR Pub. 22/FCC Class B Units VAC Hz Conditions Min. Typ. Max. See Model Selection Guide See Model Selection Guide ±1.0 ±2.0 VIN = Min to Max ±0.5 ±1.0 IO = Min to Max ±0.5 ±1.0 IO = Min to Max ±2.5 ±5.0 5.0 VDC Output 1.5 1.8 All Other Outputs 0.8 1.0 115 VAC, 60 Hz 20 ±0.02 Zener Diode Clamp 120 Continuous (Autorecovery) Typ. 120% to 180% of Output Power Units A Pk Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation, Single Output Load Regulation, Dual, Triple Aux Output Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Over Voltage Protection Short Circuit Protection, Note 3 Overload Protection, Note 4 % % % % %VP-P of VO mSec %/°C % of VO General Parameter Isolation Voltage Isolation Test Voltage Isolation Resistance EMI/RFI Conditions Input to Output Input to Output, Flash Tested For 60S 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge EMC Compliance Switching Frequency Min. 3,000 4,700 500 Typ. Max. Units VAC VAC M EN 55022 Level B EN 61000-4-2 Level 3 EN 61000-4-3 EN 61000-4-4 Level 3 2 kV EN 61000-4-5 Level 3 1kV/2 kV 100 kHz Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Conditions Ambient Min. Typ. Max. -25 +25 +71 -40 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Units °C °C % 2.91 x 2.13 x 0.76 Inches (74.0 x 54.0 x 19.3 mm) Non-Conductive Plastic& Fiberglass (UL94-V0) 4.01 Oz (114g) Reliability Specifications Parameter MTBF Safety Standards Safety Approvals Safety Class Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 280 UL 60950, EN 60950 UL, cUL; File No. E245422 IEC 61140 Class II www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Model Number Output 1 (Vout 1) Current (A) Voltage 115 VAC 230 VAC (VDC) Max. Min. MPM-15S-05IS MPM-15S-12IS MPM-15S-15IS MPM-15S-24IS MPM-15S-48IS MPM-15D-12IS MPM-15D-15IS MPM-15T-0512IS MPM-15T-0515IS Input Current (A) 0.290 0.275 0.275 0.275 0.273 0.275 0.275 0.290 0.284 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 5.0 12.0 15.0 24.0 48.0 +12.0 +15.0 5.0 5.0 3.000 1.250 1.000 0.625 0.310 +0.625 +0.500 2.000 1.80 Other output combinations are available Contact the factory for details at: [email protected] Output 2 (Vout 2) Current (A) Voltage (VDC) Max. Min. 0.300 0.125 0.100 0.063 0.030 +0.063 +0.050 +0.200 +0.200 -12.0 -15.0 +12.0 +15.0 -0.625 -0.500 +0.200 +0.150 Output 3 (Vout 3) Current (A) Voltage (VDC) Max. Min. -0.063 -0.050 +0.020 +0.015 -12.0 -15.0 -0.200 -0.150 -0.020 -0.015 Capacitive Efficiency Load (%, Typ) (µF, Max) 3,900 2,200 2,200 2,200 1,000 ±1,500 ±1,500 Note 5 Note 5 75 79 79 79 79 79 79 74 74 Derating Curve Notes: 1. Load regulation is measured for an output change of 0% to 100% at nominal input line. For multiple output models, the loads are balanced. 2. Operation at no-load will not damage these units. However, they may not meet all specifications. 3. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 4. Output overload protection is provided by a fold back current limiting circuit. 5. For triple output models, the maximum capacitive load for the primary (5 VDC) output is 2,200 µF. For the auxilliary outputs it is ±1,500 µF. 6. The MPM-15IS series includes a built-in 2A/250 VAC fuse. It is recommended that an external 1.5A slow blow fuse also be used on the input for protection. Model Number Mechanical Dimensions Pin Connections Pin Single 1 AC-Neutral 2 AC-Line 3 NP 4 -Vo 5 NP 6 +Vo 7 NP NP = No Pin Dual Triple AC-Neutral AC-Line NP -Vo Common +Vo NP AC-Neutral AC-Line -Vo 3 Common +Vo 2 -Vo 1 +Vo 1 Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]