XP Power JTH1548S15 15 watts jth sery Datasheet

DCDC
15 Watts
JTH Series
xppower.com
•
4:1 Input Range
•
1500 VDC Isolation
•
Efficiency up to 86%
•
40 °C to +100 °C Operating Temperature
•
Optional Remote On/Off
•
Single & Dual Outputs
•
3 Year Warranty
Specification
Input
Input Voltage Range
Input Current
Input Filter
Input Reflected
Ripple Current
Input Surge
Undervoltage Lockout
General
• 24 V (9-36 VDC)
48 V (18-72 VDC)
• See table
• Pi network
• 35 mA rms through 12 µH inductor
• 24 V models 40 VDC for 100 ms
48 V models 80 VDC for 100 ms
• 24 V models ON 8.6 V, OFF 8 VDC typical
48 V models ON 16.0 V, OFF 14 V typical
• See table
• 1500 VDC Input to Output
1000 VDC Input to Case
1000 VDC Output to Case
Isolation Resistance
Isolation Capacitance
Switching Frequency
Power Density
MTBF
•
•
•
•
•
109Ω
1200 pF typical
300 kHz typical
18.75 W/in3
>1.21 MHrs to MIL-HDBK-217F
at 25 °C, GB
Environmental
Output
Output Voltage
Minimum Load
Line Regulation
Load Regulation
•
•
•
•
Cross Regulation
Setpoint Accuracy
Start Up Delay
Start Up Rise Time
Ripple & Noise
Transient Response
•
•
•
•
•
•
Temperature
Coefficient
Overvoltage Protection
Overcurrent Protection
Short Circuit Protection
•
Remote On/Off
Maximum Capacitive
Load
Efficiency
Isolation
See table
No minimum load required
±0.5%
±0.5% 10-100% load,
±1.0% 10% load
±5% on dual output models (see note 3)
±1%
<10 ms
<20 ms
75 mV pk-pk 20 MHz bandwidth
3% max deviation, recovery to within
1% in 200 µs for 25% load change
0.02%/°C
• None
• 140% typical of full load at nominal input
• Trip & restart (hiccup mode),
auto recovery
• Optional (see application note)
• See table
Operating Temperature • -40 °C to +100 °C, derate from 100% load
at +60 °C to 0% load at +100 °C
Case Temperature
• 100 °C max
Cooling
• Convection-cooled
Operating Humidity
• Up to 95% RH, non-condensing
Storage Temperature • -40 °C to +125 °C
EMC
Emissions
ESD Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
• EN55022 class A conducted &
radiated with external components,
see application note
• EN61000-4-2,
8 kV air discharge Perf Criteria A,
4 kV contact discharge Perf Criteria A
• EN61000-4-4, level 1 Perf Criteria A*
• EN61000-4-5, installation class 1,
Perf Criteria A*
• EN61000-4-6, 3 Vrms Perf Criteria A
• EN61000-4-8, 1 A/m Perf Criteria A
*External input capacitor required 220 µF/100 V
Input Voltage
Range
Output Voltage
Input Current(1)
No Load
Full Load
25 mA
515 mA
25 mA
753 mA
25 mA
735 mA
25 mA
726 mA
25 mA
753 mA
25 mA
735 mA
25 mA
726 mA
Output Current
9-36 VDC
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
V
V
V
V
V
V
V
3000
3000
1250
1000
±1500
±625
±500
mA
mA
mA
mA
mA
mA
mA
18-72 VDC
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
V
V
V
V
V
V
V
3000
3000
1250
1000
±1500
±625
±500
mA
mA
mA
mA
mA
mA
mA
20
20
20
20
20
20
20
mA
mA
mA
mA
mA
mA
mA
257
376
367
363
376
367
363
Efficiency
mA
mA
mA
mA
mA
mA
mA
Max.
Capacitive Load
Model Number(2)
80%
83%
85%
86%
83%
85%
86%
3300
3300
680
470
±2200
±470
±330
µF
µF
µF
µF
µF
µF
µF
JTH1524S3V3
JTH1524S05
JTH1524S12
JTH1524S15
JTH1524D05
JTH1524D12
JTH1524D15
80%
83%
85%
86%
83%
85%
86%
3300
3300
680
470
±2200
±470
±330
µF
µF
µF
µF
µF
µF
µF
JTH1548S3V3
JTH1548S05
JTH1548S12
JTH1548S15
JTH1548D05
JTH1548D12
JTH1548D15
Notes
1. Measured at nominal input voltage.
2. For optional Remote On/Off. add suffix ‘-R’ to model number.
3. Cross regulations is ±5% when one output is at 100% and the other is varied
between 25% and 100%.
Mechanical Details
0.40
(10.1)
0.10
(2.5)
1.00 (25.4)
0.40
(10.1)
0.10
(2.5)
3
0.80
(20.3)
Pin
1
2
3
4
5
6*
ø 0.04
(1.0)
0.60
(15.2)
2.00
(50.8)
0.40
(10.1)
5
4
Bottom View
1
2
PIN CONNECTIONS
Single
Dual
+Vin
+Vin
-Vin
-Vin
+Vout
+Vout
No pin
Common
-Vout
-Vout
ROF*
ROF*
* Pin 6 only present with optional
Remote On/Off
6
Notes
0.60
(15.2)
0.40
(10.1)
0.20
(5.0)
0.20
(5.0)
Min
0.40
(10.1)
1. All dimensions are in inches (mm).
2. Weight: 0.07 lbs (30 g)
3. Pin diameter: 0.04 +/- 0.002 (1.0 +/- 0.05)
4. Pin pitch tolerance: +/-0.014 (+/-0.35)
5. Case tolerance: +/- 0.02 (+/-0.5)
Application Notes
Derating Curve
Optional Remote On/Off
On = +2.5 to +5.5 VDC on pin 6 WRT pin 2 or open circuit
Off = -0.7 to +0.8 VDC on pin 6 WRT pin 2 or short circuit pin 2 & 6
Output Power (%)
100
Input current is typically 2.5 mA when output is remotely switched off.
75
50
Input Filter
+Vout
25
+Vin
+
12 µF
-40
-20
0
20
40
60
Ambient Temperature (°C)
80
100
47 µF
120
-
DC/DC
Converter
33 µF
Load
-Vin
-Vout
30-June-11
DCDC
JTH15
Models and Ratings
Similar pages