Vitec ITDA180I-S280SI 180w desktop power supply for i.t. equipment Datasheet

ITDA180I SERIES
180W Desktop Power Supply for I.T. Equipment
–
–
–
–
–
–
–
–
2 Year Warranty
Wide Input Voltage 90 to 264VAC, 47 to 63Hz
Constant Output Voltage Available From 12VDC To 48VDC
Over Voltage, Over Current, Short Circuit, and Over Temperature Protection
High Efficiency (over 90%), Active Power Factor Correction (PFC)
Energy Star 2.0, CEC Level V, and RoHS Compliance
UL/C-UL, TUV-GS, CE Certifications
Output connector shield connects back to earth ground.
EMC: FCC Part 15 Class B & EN55022 Class B
Approvals:
Single Output
Part Number
Output Voltage
ITDA180I-S120SI
ITDA180I-S190SI
ITDA180I-S240SI
ITDA180I-S280SI
ITDA180I-S360SI
ITDA180I-S480SI
12 VDC
19 VDC
24 VDC
28 VDC
36 VDC
48 VDC
Max.
Output Current
14.16 A
9.47 A
7.50 A
6.42 A
5.00 A
3.75 A
Efficiency
(220VAC, Full Load)
91.5%
92.5%
93.5%
93.5%
93.5%
93.5%
Over Voltage
Protection
16V
26V
33V
39V
50V
60V
Max.
Output Power
170W
180W
180W
180W
180W
180W
Electrical Characteristics
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
High Line Inrush Current
Power Factor Correction
Efficiency
No-Load Power Consumption
Line Regulation
Load Regulation
Over Voltage Protection
Over Current Protection
Over Temperature Protection
Short Circuit Protection
Output Overshoot / Undershoot
Start Up Time
Hold-Up Time
Rise Time
Fall Time
Ripple & Noise (Peak to Peak)
Test Conditions
Operating Voltage
Min.
90
47
0
Typ.
Max.
264
63
180
2.3
0.9
50
Vin=90 to 264VAC
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Vin=110VAC
99
Io=Full Load, Vin=230VAC
91.5
93.5
No Load, VIn=230VAC
0.5
Io=Full Load
0.5
Vin=230VAC
5
Latch mode. The power unit shall return to normal operation only after the power is turn-on again.
120
Hiccup mode. Self-recovery when fault is removed.
140
170
125
No damage shall occur when any output operating in a short circuit condition.
The power supply shall be self-recovery when the fault condition is removed.
When power on or off
10
Io=Full Load, Vin=90VAC
2
Full Load, Vin=90~264VAC
9
25
Full Load
30
Measured by 20 MHz bandwidth oscilloscope and the
output paralleled a 0.1 uF ceramic capacitor and a 10 uF
1.5
electrolytic capacitor.
Unit
VAC
Hz
W
A
A
A
%
%
W
%
%
% Io
°C
%
S
mS
mS
mS
% Vo
Conditions
Parameter
Test Conditions
Operating Temperature
Humidity: 10% RH to 90% RH
Storage Temperature
Humidity: 5% RH to 95% RH
Operation temperature at 25°C, calculated per MIL-HDBK-217F
Min.
0
-20
0.45M
Typ.
Max.
Unit
+40
80
°C
°C
Hours
Approvals and Compliance
Parameter
EMI
Standards
Safety UL/c-UL, T-mark, CE
EN 55022:1998, +A1:2000 +A2:2003, Class B, CISPR 22:2003, Class B, AS/NZS CISPR 22: 2004, Class B
EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4.3, , EN61000-4-4, , EN61000-4-5, EN61000-4-6,
EN61000-4-8, EN61000-4-1-1
UL/C-UL60950-1, EN60950-1
Environmental Compliance
RoHS
EMS
Mechanical
Parameter
Specification
Dimension, Net Weight
180x70.5x42mm (7.08x2.78x1.65 inches)
Weight
595g
The output connector shield/foil is connected back to earth ground, and isolated from both +output and output return.