Actel COREAI-UG Coreai Datasheet

CoreAI
Product Summary
Synthesis and Simulation Support
Intended Use
•
Analog Interface Control Using a Microprocessor/
Microcontroller and an Actel FusionTM Device
•
Voltage, Current, and Temperature Monitoring
Using a Microprocessor/Microcontroller and an
Actel Fusion Device
ADC Conversions Controlled by MCU/MPU Writes
•
AMBA APB Slave Interface (8- or 16-Bit Data
Widths Supported)
•
14 Maskable Interrupt Sources
•
Internal Clock Divider for Generating Analog
Configuration MUX Clock
•
Optional Read FIFO Stores up to 256 ADC
Conversion Results
•
Analog Configuration MUX Can Be Configured by
SmartGen
Fusion (including M7 devices)
Evaluation Version
–
•
–
•
•
Simulation: OVI-Compliant Verilog Simulators and
Vital-Compliant VHDL Simulators
•
Comprehensive VHDL and Verilog Testbenches
•
User Can Easily Modify User Testbench Using
Existing Format to Add Custom Tests
Compiled RTL Simulation Model Fully
Supported in Actel Libero® Integrated Design
Environment (IDE)
Netlist Version
–
•
Synthesis: Synplicity®, Synopsys® (Design Compiler /
FPGA Compiler / FPGA Express), Exemplar
General Description ................................................... 1
Functional Block Descriptions ................................... 3
CoreAI Device Requirements ..................................... 3
CoreAI Verification ..................................................... 3
I/O Signal Descriptions ............................................... 4
Parameter/Generic Descriptions ................................ 6
Internal CoreAI Registers ......................................... 10
ACM Interface .......................................................... 18
RTC Operation .......................................................... 21
ADC Operation ......................................................... 22
Interrupt Logic ......................................................... 23
Ordering Information .............................................. 24
Datasheet Categories ............................................... 24
Core Deliverables
•
•
Contents
Supported Families
•
Directly Supported within Actel Libero IDE and
CoreConsole
Core Verification
Key Features
•
•
General Description
Structural Verilog and VHDL Netlists (with and
without I/O Pads) Compatible with Actel
Designer Software Place-and-Route Tool
Compiled RTL Simulation
Supported in Actel Libero IDE
Model
CoreAI (Analog Interface) allows for simple control of
the analog peripherals within the Fusion family of Actel
devices. Control may be implemented with an internal or
external microprocessor or microcontroller (such as
Core8051 or CoreMP7), or with user-created custom logic
within the FPGA fabric. The industry-standard AMBA
(Advanced Microcontroller Bus Architecture) APB
(Advanced Peripheral Bus) slave interface is used as the
primary control mechanism within CoreAI.
Fully
RTL Version
–
Verilog and VHDL Core Source Code
–
Core Synthesis Scripts
Testbench (Verilog and VHDL)
CoreAI instantiates the AB (Analog Block) macro, as
shown in Figure 1 on page 2. The AB macro includes the
March 2006
© 2006 Actel Corporation
v 2 .0
1
CoreAI
ACM (Analog Configuration MUX) interface, Analog
Quads, and RTC (Real-Time Counter). The ACM interface,
within the AB macro, is used to control configuration of
the Analog Quads and RTC in the Fusion device. CoreAI
generates the control signals used by the ACM, including
its clock signal, which is generated by an internal clock
divider. The ACM clock divider is used to ensure that the
ACM interface is clocked at a frequency less than or
equal to 10 MHz (refer to "ACM Interface" on page 18
for details). For more details on the silicon features of
the AB macro, such as the Analog Quads, RTC, or ACM,
refer to the Fusion datasheet.
Several aspects of CoreAI can be configured using toplevel parameters (Verilog) or generics (VHDL). For a
detailed description of the parameters/generics, refer to
Table 4 on page 6.
The CoreAI block diagram is shown in Figure 1. A typical
application using CoreAI is shown in Figure 2.
CoreAI
APB I/F
µProcessor I/F
Logic
Interrupt
ACM I/F
Logic
ADC I/F
Logic
Analog Inputs
Analog Outputs
RTC Inputs
AB
(Analog Block)
Analog Inputs
Used as
Digital Inputs
RTC Outputs
Figure 1 • CoreAI Block Diagram
Fusion Device
CoreMP7
CoreAI
CorePWM
Figure 2 • CoreAI Typical Application
2
v2.0
Temperature Monitor
Bipolar Transistor
CoreAI
Functional Block Descriptions
maskable interrupt. The ACM interface block writes
configuration data into the AB macro to control Analog
Quad and RTC settings. The ADC interface block sends
control data to and receives status information from the
ADC.
CoreAI, shown in Figure 1 on page 2, consists of the
microprocessor interface logic, ACM interface logic, and
ADC interface logic blocks. The microprocessor interface
logic implements APB slave logic and generates a
CoreAI Device Requirements
CoreAI has been implemented in the Actel Fusion device family. A summary of the data for CoreAI is listed in Table 1
and Table 2.
Table 1 • CoreAI Device Utilization and Performance (minimum configuration)
Cells or Tiles
Family
Fusion
Utilization
Sequential
Combinatorial
Total
Device
Total
Performance
45
105
150
AFS090
7%
150 MHz
Note: Data in this table were achieved using typical synthesis and layout settings. Top-level parameters/generics that differ from the
default values were set as follows: FIXED_VAREFSEL = 1, FIXED_VAREFSEL_VAL = 0, FIXED_MODE = 1, FIXED_MODE_VAL = 0,
FIXED_TVC = 1, FIXED_TVC_VAL = 0, FIXED_STC = 1, FIXED_STC_VAL = 0, CFG_ACx = 512, CFG_ATx = 512, DISABLE_TMSTBINT = 1,
CFG_GDx = 768, ACTLOW_INTERRUPT = 0, DISABLE_INTERRUPT = 1, APB_16BIT_DATA = 1.
Table 2 • CoreAI Device Utilization and Performance (maximum configuration)
Family
Fusion
Cells or Tiles
Utilization
Performance
Sequential
Combinatorial
Total
FIFO
Device
Total
130
330
460
1
AFS090
20%
133 MHz
Note: Data in this table were achieved using typical synthesis and layout settings. Top-level parameters/generics that differ from the
default values were set as follows: ACM_CLK_DIV = 4, USE_RTC = 1, USE_RDFIFO = 1, USE_RDFIFO_AEVAL = 16,
USE_RDFIFO_AFVAL = 240.
CoreAI Verification
The comprehensive simulation testbench verifies correct operation of the CoreAI macro.
The testbench applies several tests to the CoreAI macro, including the following:
•
Voltage monitor, current monitor, and temperature monitor tests
•
RTC tests
•
Gate-driver control tests
Using the supplied testbench as a guide, the user can alter the verification of the core by adding custom tests or
removing existing tests.
v2.0
3
CoreAI
I/O Signal Descriptions
The port signals for the CoreAI macro are defined in Table 3 and illustrated in Figure 3. CoreAI has 120 I/O signals.
Note that vector notation is used in Figure 3 for the AV, AC, AT, ATRETURN, DDGDON, DAVOUT, DACOUT, DATOUT,
AG, and RTCXTLMODE ports; however, these ports are actually split into individual single-bit ports, as described in
Table 3. For example, there are two individual output ports, RTCXTLMODE1 and RTCXTLMODE0, rather than one
vectored output port RTCXTLMODE[1:0].
PRDATA[7:0]
INTERRUPT
DAVOUT[9:0]
DACOUT[9:0]
DATOUT[9:0]
AG[9:0]
RTCXTLMODE[1:0]
RTCXTLSEL
RTCMATCH
RTCPSMMATCH
PCLK
PRESETN
PADDR[4:0]
PSEL
PENABLE
PWRITE
PWDATA[7:0]
VAREF
GNDREF
AV[9:0]
AC[9:0]
AT[9:0]
ATRETURN[4:0]
DDGDON[9:0]
RTCCLK
Figure 3 • CoreAI I/O Signal Diagram
Table 3 • CoreAI I/O Signal Descriptions
Name
Type
Description
PCLK
Input
APB System Clock: reference clock for all internal logic
PRESETN
Input
APB active-low asynchronous reset
PADDR[4:0]
Input
APB address bus – This port is used to address internal CoreAI registers.
PSEL
Input
APB Slave Select – This signal selects CoreAI for reads or writes.
PENABLE
Input
APB Strobe – This signal indicates the second cycle of an APB transfer.
PWRITE
Input
APB Write/Read – If high, a write will occur when an APB transfer to CoreAI takes place; if
low, a read from CoreAI will take place.
PWDATA[15:0]
Input
APB write data – If the APB_16BIT_DATA parameter/generic is set to 1, all 16 bits are used; if
the APB_16BIT_DATA parameter/generic is set to 0, only the lower 8 bits, PWDATA[7:0], are
used (in this case, PWDATA[15:8] should be tied to static high or low values).
PRDATA[15:0]
Output
APB read data – If the APB_16BIT_DATA parameter/generic is set to 1, all 16 bits are used; if
the APB_16BIT_DATA parameter/generic is set to 0, only the lower 8 bits, PRDATA[7:0], are
used (in this case, PRDATA[15:8] can be left unconnected).
INTERRUPT
Output
Microprocessor interrupt output – This interrupt signal is generated from 14 possible
interrupt sources, each of which can be masked or enabled via the INTENABLE register. The
polarity of this output is controlled via the ACTLOW_INTERRUPT parameter/generic.
APB Interface
Note: All signals active high (logic 1) unless otherwise noted.
4
v2.0
CoreAI
Table 3 • CoreAI I/O Signal Descriptions (Continued)
Name
Type
Description
Analog Interface
VAREF
Input or
Output
Voltage reference – If using the internal voltage reference, this signal will be an output; if
using an external voltage reference, this signal will be an input for this reference (see the
FIXED_VAREFSEL and FIXED_VAREFSEL_VAL parameters/generics).
GNDREF
Input
Ground reference – If external voltage reference is used, this signal must be connected to the
ground for the reference; otherwise this should be connected to digital ground (logic 0).
AV9, AV8, AV7, AV6, AV5,
AV4, AV3, AV2, AV1, AV0
Input
Analog Voltage Monitor inputs – These signals correspond to the AVx voltage monitor inputs
(AV9 through AV0) of the AB macro.
Note: Unused AVx inputs need to be disabled with the CFG_AVx parameters/generics and
connected to logic 0.
AC9, AC8, AC7, AC6, AC5,
AC4, AC3, AC2, AC1, AC0
Input
Analog Current Monitor inputs – These signals correspond to the ACx current monitor
inputs (AC9 through AC0) of the AB macro.
Note: Unused ACx inputs need to be disabled with the CFG_ACx parameters/generics and
connected to logic 0.
AT9, AT8, AT7, AT6, AT5,
AT4, AT3, AT2, AT1, AT0
Input
Analog Temperature Monitor inputs – These signals correspond to the ATx temperature
monitor inputs (AT9 through AT0) of the AB macro.
Note: Unused ATx inputs need to be disabled with the CFG_ATx parameters/generics and
connected to logic 0.
ATRETURN4, ATRETURN3,
ATRETURN2, ATRETURN1,
ATRETURN0]
Input
Shared Analog Temperature Monitor Returns – These signals correspond to the shared
returns for the temperature monitor inputs (ATRETURN89 through ATRETURN01) of the AB
macro.
DAVOUT9, DAVOUT8,
DAVOUT7, DAVOUT6,
DAVOUT5, DAVOUT4,
DAVOUT3, DAVOUT2,
DAVOUT1, DAVOUT0
Output
Digital AV outputs – These signals correspond to the digital AV outputs (DAVOUT9 through
DAVOUT0) of the AB macro. If any of the AVx inputs are configured as digital inputs rather
than analog inputs, their corresponding buffered digital signals are put out on these ports.
DACOUT9, DACOUT8,
DACOUT7, DACOUT6,
DACOUT5, DACOUT4,
DACOUT3, DACOUT2,
DACOUT1, DACOUT0
Output
Digital AC outputs – These signals correspond to the digital AC outputs (DACOUT9 through
DACOUT0) of the AB macro. If any of the ACx inputs are configured as digital inputs rather
than analog inputs, their corresponding buffered digital signals are put out on these ports.
DATOUT9, DATOUT8,
DATOUT7, DATOUT6,
DATOUT5, DATOUT4,
DATOUT3, DATOUT2,
DATOUT1, DATOUT0
Output
Digital AT outputs – These signals correspond to the digital AT outputs (DATOUT9 through
DATOUT0) of the AB macro. If any of the ATx inputs are configured as digital inputs rather
than analog inputs, their corresponding buffered digital signals are put out on these ports.
Input
Direct Digital Gate Driver enables – These signals can control the corresponding GDONx
gate-driver enable inputs (GDON9 through GDON0) of the AB macro if the CFG_GDx
parameters/generics are set appropriately (refer to "Parameter/Generic Descriptions" on
page 6).
Output
Analog Gate Driver outputs – These signals correspond to the AGx gate driver outputs (AG9
through AG0) of the AB macro.
DDGDON9, DDGDON8,
DDGDON7, DDGDON6,
DDGDON5, DDGDON4,
DDGDON3, DDGDON2,
DDGDON1, DDGDON0
AG9, AG8, AG7 AG6, AG5,
AG4, AG3, AG2, AG1, AG0
Note: If unused, each of these gate driver outputs can be disabled via the CFG_GDx
parameters/generics.
Note: All signals active high (logic 1) unless otherwise noted.
v2.0
5
CoreAI
Table 3 • CoreAI I/O Signal Descriptions (Continued)
Name
Type
Description
RTCCLK
Input
RTC Clock input – If the RTC is used (via the USE_RTC parameter/generic), this input must
come from the internal crystal oscillator (XTLOSC) CLKOUT pin; if the RTC is not used, this
pin should be tied low.
RTCXTLMODE1,
RTCXTLMODE0
Output
RTC XTLOSC Mode outputs – If the RTC is used (via the USE_RTC parameter/generic), these
output ports must be connected to the internal crystal oscillator (XTLOSC) RTCMODE[1:0]
pins; if the RTC is not used, these pins should be left unconnected.
RTCXTLSEL
Output
RTC XTLOSC Mode Selection output – If the RTC is used (via the USE_RTC parameter/
generic), this output port must be connected to the internal crystal oscillator (XTLOSC)
MODESEL pin; if the RTC is not used, this pin should be left unconnected.
RTCMATCH
Output
RTC Match output – If the RTC is used (via the USE_RTC parameter/generic), this output port
indicates that a match event has occurred and can be connected to other FPGA logic; if the
RTC is not used, this pin should be left unconnected.
RTCPSMMATCH
Output
RTC Match VRPSM output – If the RTC is used (via the USE_RTC parameter/generic), this
output port can be connected to the VRPSM pin of the internal voltage regulator to control
regulator power-up; if the RTC is not used, this pin should be left unconnected.
Note: All signals active high (logic 1) unless otherwise noted.
Parameter/Generic Descriptions
CoreAI has parameters (Verilog) and generics (VHDL), described in Table 4, for configuring the RTL code. All
parameters and generics are integer types.
Table 4 • CoreAI Parameters/Generics Descriptions
Name
Valid Range
Description
APB_16BIT_DATA
0 or 1
Set this to 1 if the APB reads and writes are using all 16-bits of the
PRDATA[15:0] and PWDATA[15:0] ports, or to 0 if 8-bit APB reads and writes
are done on the PRDATA[15:0] and PWDATA[15:0] ports. If 8-bit APB reads
and writes are used, only the lower eight bits of each port are used, i.e.,
PRDATA[7:0] and PWDATA[7:0]; PWDATA[15:8] should be tied statically high
or low and PRDATA[15:8] should be left unconnected in this case. Note that
for 16-bit reads and writes, the internal address map shown in Table 9 on
page 11 will concatenate adjacent bytes since PADDR[0] will be ignored; in
this case, each byte that is addressed by PADDR[0] = 0 will correspond to the
LSB and each byte that is addressed by PADDR[0] = 1 will correspond to the
MSB of each 16-bit word. The default value of 0 uses 8-bit APB reads and
writes.
ACTLOW_INTERRUPT
0 or 1
Interrupt Active Low: Set this to 1 if the INTERRUPT output polarity is active
low, or to 0 if the INTERRUPT output polarity is active high. The default value
of 0 is active high.
DISABLE_INTERRUPT
0 or 1
Disable Interrupt: Set this to 1 if the INTERRUPT output will not be used, in
which case the INTERRUPT output will be fixed at the inactive polarity chosen
by ACTLOW_INTERRUPT, i.e., INTERRUPT = ACTLOW_INTERRUPT; set this to 0
if the INTERRUPT output is used. The default value of 0 uses the INTERRUPT
output.
Note: *Invalid values are 3, 7, 11, and 15 (refer to the Fusion datasheet).
6
v2.0
CoreAI
Table 4 • CoreAI Parameters/Generics Descriptions (Continued)
Name
ACM_CLK_DIV
Valid Range
Description
1 to 4
Set this to the division value to generate the ACM clock, which has a
maximum frequency of 10 MHz. The actual value will be the frequency of
PCLK divided by (2ACM_CLK_DIV); valid values are 1–4. The default value of 1
sets the ACM clock at half the PCLK frequency.
Note: It is the user’s responsibility to ensure that the ACM clock has a
maximum operating frequency of 10 MHz.
USE_RTC
0 or 1
Use RTC: Set this to 1 if the RTC is to be used, or to 0 if the RTC is not to be
used. The default value of 0 does not use the RTC.
USE_RDFIFO
0 or 1
Use Read FIFO: Set this to 1 if using an internal data FIFO for storing up to 256
ADC conversion results for later reading by a microprocessor, or to 0 if not
using the FIFO. The default value of 0 does not use a read FIFO.
0 to 255
Read FIFO Almost Empty Value: Set this 8-bit integer to the fixed almost empty
value of the read FIFO. This value determines when the almost empty flag
output from the read FIFO becomes active; it represents the number of 16-bit
ADC conversion result words that are left to be read before the read FIFO will
be empty.
USE_RDFIFO_AEVAL
Note: This is only used if USE_RDFIFO = 1.
USE_RDFIFO_AFVAL
0 to 255
Read FIFO Almost Full Value: Set this 8-bit integer to the fixed almost full value
of the read FIFO. This value determines when the almost full flag output from
the read FIFO becomes active; it represents the number of 16-bit ADC
conversion result words that are left to be written before the read FIFO will be
full.
Note: This is only used if USE_RDFIFO = 1.
FIXED_VAREFSEL
0 or 1
Set this to 1 if the VAREFSEL input pin of the AB macro is to be fixed, or to 0 to
allow register-controlled VAREFSEL setting (saves some logic tiles for a fixed
system). The default value of 0 does not have a fixed VAREFSEL setting.
FIXED_VAREFSEL_VAL
0 or 1
Fixed VAREFSEL Value: Set this to a 1-bit constant value (set in higher-level
wrapper). Set to 1 to select external VAREF as input, 0 to select internal VAREF
as output.
Note: This is only used if FIXED_VAREFSEL = 1.
FIXED_MODE
FIXED_MODE_VAL
FIXED_TVC
FIXED_TVC_VAL
0 or 1
Set this to 1 if the MODE[3:0] pins of the AB macro are a fixed constant, or to
0 to allow register-controlled MODE[3:0] setting (saves some logic tiles for a
fixed system). The default of 0 does not have a fixed MODE[3:0] setting.
0 to 2,
4 to 6,
8 to 10,
12 to 14*
Fixed MODE Value: Set this to the integer value of the 4-bit fixed constant
connected to the MODE[3:0] input pins of the AB macro (controls ADC
resolution, etc.).
0 or 1
Set this to 1 if the TVC[7:0] pins of the AB macro are a fixed constant, or to 0
to allow register-controlled TVC[7:0] setting (saves some logic tiles for a fixed
system). The default value of 0 does not have a fixed TVC[7:0] setting.
0 to 255
Fixed TVC Value: Set this to the integer value of the 8-bit fixed constant
connected to the TVC[7:0] inputs of the AB macro.
Note: This is only used if FIXED_MODE = 1.
Note: This is only used if FIXED_TVC = 1.
FIXED_STC
0 or 1
Set this to 1 if the STC[7:0] pins of the AB macro are a fixed constant, or to 0
to allow register-controlled STC[7:0] setting (saves some logic tiles for a fixed
system). The default value of 0 does not have a fixed STC[7:0] setting.
Note: *Invalid values are 3, 7, 11, and 15 (refer to the Fusion datasheet).
v2.0
7
CoreAI
Table 4 • CoreAI Parameters/Generics Descriptions (Continued)
Name
FIXED_STC_VAL
Valid Range
Description
0 to 255
Fixed STC Value: Set this to the integer value of the 8-bit fixed constant
connected to the STC[7:0] inputs of the AB macro.
Note: This is only used if FIXED_STC = 1.
DISABLE_TMSTBINT
0 or 1
Disable Internal Temperature Monitor Strobe: Set this 1-bit integer to disable
the internal temperature monitor strobes. If this bit is set to 1, the TMSTBINT
input is disabled; if it is set to 0, the TMSTBINT input is register-controlled. The
default value of 0 allows the internal temperature monitor strobe to be
controlled via register settings.
CFG_AV9, CFG_AV8, CFG_AV7,
CFG_AV6, CFG_AV5, CFG_AV4,
CFG_AV3, CFG_AV2, CFG_AV1,
CFG_AV0
0 to 1,023
Configure AVx Inputs: Set each of these 10-bit integers to configure the AV9
through AV0 inputs that are connected to the AB macro. The lower 8 bits of
each of these 10-bit integers are reserved for generating firmware settings for
the target processor used with CoreAI and are ignored by the CoreAI
hardware. The upper 2 bits are used to create the settings for each AVx input,
shown in Table 5 on page 9.
For example, if CFG_AV5 is set to the binary value 0000000000 (decimal 0),
the AV5 input will be used as an analog voltage monitor input. If CFG_AV5 is
set to the binary value 0100000000 (decimal 256), the AV5 input will be used
as a digital input, and the buffered DAVOUT5 output would be connected to
the user’s own logic. If CFG_AV5 is set to the binary value 1100000000
(decimal 768), the AV5 input will be disabled; in this case, the CoreAI AV5
input will not be used and the AV5 input of the AB macro will be hardwired to
logic 0 within CoreAI.
CFG_AC9, CFG_AC8, CFG_AC7,
CFG_AC6, CFG_AC5, CFG_AC4,
CFG_AC3, CFG_AC2, CFG_AC1,
CFG_AC0
0 to 1,023
Configure ACx Inputs: Set each of these 10-bit integers to configure the AC9
through AC0 inputs that are connected to the AB macro. The lower 8 bits of
each of these 10-bit integers are reserved for generating firmware settings for
the target processor used with CoreAI and are ignored by the CoreAI
hardware. The upper 2 bits are used to create the settings for each ACx input,
shown in Table 6 on page 9.
For example, if CFG_AC7 is set to the binary value 0000000000 (decimal 0),
the AC7 input will be used as an analog current monitor input. If CFG_AC7 is
set to the binary value 0100000000 (decimal 256), the AC7 input will be used
as a digital input, and the buffered DACOUT7 output would be connected to
the user’s own logic. If CFG_AC7 is set to the binary value 1000000000
(decimal 512), the AC7 input will be used as an analog voltage monitor input.
If CFG_AC7 is set to the binary value 1100000000 (decimal 768), the AC7
input will be disabled; in this case, the CoreAI AC7 input will not be used and
the AC7 input of the AB macro will be hardwired to logic 0 within CoreAI.
Note: *Invalid values are 3, 7, 11, and 15 (refer to the Fusion datasheet).
8
v2.0
CoreAI
Table 4 • CoreAI Parameters/Generics Descriptions (Continued)
Name
Valid Range
Description
CFG_AT9, CFG_AT8, CFG_AT7,
CFG_AT6, CFG_AT5, CFG_AT4,
CFG_AT3, CFG_AT2, CFG_AT1,
CFG_AT0
0 to 1,023
Configure ATx Inputs: Set each of these 10-bit integers to configure the AT9
through AT0 inputs that are connected to the AB macro. The lower 8 bits of
each of these 10-bit integers are reserved for generating firmware settings for
the target processor used with CoreAI and are ignored by the CoreAI
hardware. The upper 2 bits are used to create the settings for each ATx input,
shown in Table 7 on page 10.
For example, if CFG_AT2 is set to the binary value 0000000000 (decimal 0),
the AT2 input will be used as an analog temperature monitor input. If
CFG_AT2 is set to the binary value 0100000000 (decimal 256), the AT2 input
will be used as a digital input, and the buffered DATOUT2 output would be
connected to the user’s own logic. If CFG_AT2 is set to the binary value
1000000000 (decimal 512), the AT2 input will be used as an analog voltage
monitor input. If CFG_AT2 is set to the binary value 1100000000 (decimal
768), the AT2 input will be disabled; in this case, the CoreAI AT2 input will not
be used and the AT2 input of the AB macro will be hardwired to logic 0 within
CoreAI.
CFG_GD9, CFG_GD8, CFG_GD7,
CFG_GD6, CFG_GD5, CFG_GD4,
CFG_GD3, CFG_GD2, CFG_GD1,
CFG_GD0
0 to 1,023
Configure Gate Drivers: Set each of these 10-bit integers to configure the
GDON9 through GDON0 inputs and the AG9 through AG0 outputs that are
connected to the AB macro. The lower 8 bits of each of these 10-bit integers
are reserved for generating firmware settings for the target processor used
with CoreAI and are ignored by the CoreAI hardware. The upper 2 bits are
used to create the settings shown in Table 8 on page 10.
For example, if CFG_GD1 is set to the binary value 0000000000 (decimal 0),
the AG1 gate-driver output will be controlled by a software-controlled register
within CoreAI (ADC Control Register 5). If CFG_GD1 is set to the binary value
0100000000 (decimal 256), the DDGDON1 input (connected to the user’s
own logic) will be used to directly control the AG1 gate-driver output. If
CFG_GD1 is set to the binary value 1100000000 (decimal 768), the AG1
output will be disabled; in this case, the CoreAI AG1 output will not be used
and the GDON1 input of the AB macro will be hardwired to logic 0 within
CoreAI.
Note: *Invalid values are 3, 7, 11, and 15 (refer to the Fusion datasheet).
Table 5 • Settings for AVx Inputs
CFG_AVx Bit-Position Values ('X' indicates "don’t care")
AVx Input Usage
9
8
7
6
5
4
3
2
1
0
0
0
X
X
X
X
X
X
X
X
Voltage Monitor (default)
0
1
X
X
X
X
X
X
X
X
Digital Input
1
0
X
X
X
X
X
X
X
X
Reserved (unused)
1
1
X
X
X
X
X
X
X
X
Disabled
Table 6 • Settings for ACx Inputs
CFG_ACx Bit-Position Values ('X' indicates "don’t care")
ACx Input Usage
9
8
7
6
5
4
3
2
1
0
0
0
X
X
X
X
X
X
X
X
Current Monitor (default)
0
1
X
X
X
X
X
X
X
X
Digital Input
1
0
X
X
X
X
X
X
X
X
Voltage Monitor
1
1
X
X
X
X
X
X
X
X
Disabled
v2.0
9
CoreAI
Table 7 • Settings for ATx Inputs
CFG_ATx Bit-Position Values ('X' indicates "don’t care")
ATx Input Usage
9
8
7
6
5
4
3
2
1
0
0
0
X
X
X
X
X
X
X
X
Temperature Monitor (default)
0
1
X
X
X
X
X
X
X
X
Digital Input
1
0
X
X
X
X
X
X
X
X
Voltage Monitor
1
1
X
X
X
X
X
X
X
X
Disabled
Table 8 • Settings for Gate Driver Usage
CFG_GDx Bit-Position Values ('X' indicates "don’t care")
8
7
6
5
4
3
2
1
0
0
0
X
X
X
X
X
X
X
X
Register controlled (default)
1
0
X
X
X
X
X
X
X
X
Gate Driver (AGx)
DDGDONx input
1
0
X
X
X
X
X
X
X
X
Reserved (unused)
1
1
X
X
X
X
X
X
X
X
Disabled (GDONx and AGx)
Internal CoreAI Registers
The internal register address map and reset values of
each APB-accessible register for CoreAI are shown in
Table 9 on page 11. In the case of 8-bit APB reads and
writes (APB_16BIT_DATA = 0), each PADDR[4:0] address is
significant and contains the byte listed in the far right
column; however, when 16-bit APB reads and writes are
used (APB_16BIT_DATA = 1), PADDR[4:1] addresses
contain one 16-bit word, where each two adjacent rows
in Table 9 on page 11 contain the low-order and highorder bytes, consecutively (PADDR[0] is unused in this
case).
Table 10 on page 12 through Table 31 on page 17
describe the various APB-accessible registers within
CoreAI. Unless otherwise stated, each register can be
read from or written to by an internal or external
microprocessor/microcontroller. All registers are listed
assuming 8-bit APB reads and writes; if 16-bit APB reads
and writes are used, add 8 to each item in the "Bits"
column for high-order bytes (Table 11 on page 12,
Table 15 on page 13, Table 17 on page 13, Table 19 on
page 14, Table 21 on page 14, Table 23 on page 14,
Table 25 on page 15, Table 29 on page 16, and Table 31
on page 17).
10
Gate Driver Usage
9
v2.0
controlled
by
When reading from register bits that are write-only or
unused (reserved), a logic 0 will be returned. When
writing to register bits that are read-only or unused
(reserved), no action takes place.
The INTERRUPT output is generated as the logical OR of
the interrupt enable bits (INTEN[14:0]) ANDed with the
interrupt status bits (INT[14:0]), as shown in Figure 4.
INTEN[14]
INT[14]
INTERRUPT
INTEN[0]
INT[0]
Figure 4 • CoreAI Interrupt Logic
CoreAI
Note that after an APB read of the interrupt status registers has been performed, each INT[14:0] bit will be cleared if
its condition is no longer valid. If an APB read of the interrupt status registers has just occurred coincident with a
pending interrupt condition, the interrupt condition will have priority in order to prevent a missed
interrupt.
Table 9 • CoreAI Internal Register Address Map*
PADDR[4:0]
Type
Reset Value
Brief Description
0x00
R/W
0x04
ACM Control/Status Register (low-order)
0x01
R/W
0x00
ACM Control/Status Register (high-order)
0x02
R/W
0x00
ACM Address Register
0x03
–
0x00
Reserved
0x04
R/W
0x00
ACM Data Register
0x05
–
0x00
Reserved
0x06
R/W
0x00
ADC Control Register 1 (low-order)
0x07
R/W
0x00
ADC Control Register 1 (high-order)
0x08
R/W
0x00
ADC Control Register 2 (low-order)
0x09
R/W
0x00
ADC Control Register 2 (high-order)
0x0a
R/W
0x00
ADC Control Register 3 (low-order)
0x0b
R/W
0x00
ADC Control Register 3 (high-order)
0x0c
R/W
0x00
ADC Control Register 4 (low-order)
0x0d
R/W
0x00
ADC Control Register 4 (high-order)
0x0e
R/W
0x00
ADC Control Register 5 (low-order)
0x0f
R/W
0x00
ADC Control Register 5 (high-order)
0x10
R
0x00
ADC Status Register (low-order)
0x11
R
0x00
ADC Status Register (high-order)
0x12
R
0x00
Read FIFO Data Output
0x13
–
0x00
Reserved
0x14
R
0x0c
Read FIFO Status
0x15
–
0x00
Reserved
0x16
R/W
0x00
Interrupt Enable Register (low-order)
0x17
R/W
0x00
Interrupt Enable Register (high-order)
0x18
R
0x00
Interrupt Status Register (low-order)
0x19
R
0x00
Interrupt Status Register (high-order)
Note: *Values shown in hexadecimal format. Type designations: "R" – read-only, "R/W" – read/write, "–" – Not used (to accommodate
16-bit APB access)
v2.0
11
CoreAI
Table 10 • ACM Control/Status Register (low-order)
Bits
Name
7:5
Reserved
Function
Not used
4
ACMWRBUSY
ACM Write Cycle Busy (read-only) – If 1, the ACM is busy writing data into the AB block.
3
ACMRDBUSY
ACM Read Cycle Busy (read-only) – If 1, the ACM is busy reading data from the AB block.
2
ACMRESETBUSY
1
ACMRDSTART
ACM Reset Cycle Busy (read-only) – If 1, the ACM is busy being reset.
ACM Read Start (write-only)
1 – The ACM starts a read cycle from the ACM address in the ACMADDR[7:0] bits of the ACM
Address/Data register. Note that this write-only bit is active for one ACM clock cycle (self-clearing),
and that the resulting busy signal from the ACM read taking place will be reflected in the
ACMRDBUSY bit of this register.
0 – Normal (no operation or current ACM operation continues)
0
ACMRESET
ACM Reset (write-only)
1 – The ACM is put into a reset condition. Note that this write-only bit is active for only one ACM
clock cycle (self-clearing), and that the resulting busy signal from the ACM reset taking place will
be reflected in the ACMRESETBUSY bit of this register.
0 – Normal (no operation or current ACM operation continues)
Table 11 • ACM Control/Status Register (high-order)
Bits
Name
7:0
Reserved
Function
Not used
Table 12 • ACM Address Register
Bits
Name
7:0
ACMADDR[7:0]
Function
ACM Address
These bits are connected to the ACMADDR[7:0] port of the AB macro.
(Refer to the Fusion datasheet for further information.)
Table 13 • ACM Data Register
Bits
Name
7:0
ACMDATA[7:0]
Function
ACM Data
If this register is read from, the ACMRDATA[7:0] output port from the AB block is returned.
If this register is written to, it will drive the ACMWDATA[7:0] input port of the AB block.
12
v2.0
CoreAI
Table 14 • ADC Control Register 1 (low-order)
Bits
Name
7
Reserved
6
ADCRESET
Function
Not used
ADC Reset (write-only)
1 – The ADC is given an active high pulse (connected to the ADCRESET pin of the AB macro). Note
that this write-only bit is active for only one PCLK clock cycle (self-clearing).
0 – Normal (no operation or current conversion continues)
5
PWRDN
ADC Power Down
1 – The ADC is powered down.
0 – The ADC is powered up (normal operation).
4
VAREFSEL
ADC Voltage Reference Select
1 – Select external voltage reference (3.3 V max.) to be used (input on VAREF and GNDREF ports)
0 – Select internal voltage reference (2.56 V) to be used (output on VAREF port)
3:0
MODE[3:0]
ADC Mode Selection
The mode selection bits are used to select between 8-, 10-, and 12-bit ADC resolution.
(Refer to the Fusion datasheet for further information.)
Table 15 • ADC Control Register 1 (high-order)
Bits
Name
7:0
TVC[7:0]
Function
ADC Clock Divider
(Refer to the Fusion datasheet for further information.)
Table 16 • ADC Control Register 2 (low-order)
Bits
Name
7:0
STC[7:0]
Function
ADC Sample Time Control
(Refer to the Fusion datasheet for further information.)
Table 17 • ADC Control Register 2 (high-order)
Bits
Name
7:6
Reserved
5
ADCSTART
Function
Not used
ADC Start Conversion (write-only)
1 – The ADC starts an analog-to-digital conversion on the selected channel. Note that this writeonly bit is high for only one PCLK clock cycle (self-clearing).
0 – Normal (no operation or current conversion continues)
4:0
CHNUMBER[4:0]
ADC Channel Number
This 5-bit value selects one of 32 analog channels that are fed to the analog MUX within the AB
macro.
(Refer to the Fusion datasheet for further information.)
Table 18 • ADC Control Register 3 (low-order)
Bits
Name
7:0
CMSTB[7:0]
Function
Current Monitor Strobes
These bits are connected to the CMSTB[7:0] pins of the AB macro.
(Refer to the Fusion datasheet for further information.)
v2.0
13
CoreAI
Table 19 • ADC Control Register 3 (high-order)
Bits
Name
7:2
Reserved
1:0
CMSTB[9:8]
Function
Not used
Current Monitor Strobes
These bits are connected to the CMSTB9 and CMSTB8 pins of the AB macro.
(Refer to the Fusion datasheet for further information.)
Table 20 • ADC Control Register 4 (low-order)
Bits
Name
7:0
TMSTB[7:0]
Function
Temperature Monitor Strobes
These bits are connected to the TMSTB[7:0] pins of the AB macro.
(Refer to the Fusion datasheet for further information.)
Table 21 • ADC Control Register 4 (high-order)
Bits
Name
Function
7:2
Reserved
Not used
2
TMSTBINT
Internal Temperature Monitor Strobe
This bit is connected to the TMSTBINT pin of the AB macro.
(Refer to the Fusion datasheet for further information.)
1:0
TMSTB[9:8]
Temperature Monitor Strobes
These bits are connected to the TMSTB9 and TMSTB8 pins of the AB macro.
(Refer to the Fusion datasheet for further information.)
Table 22 • ADC Control Register 5 (low-order)
Bits
Name
7:0
GDON[7:0]
Function
Gate Driver Enables
These bits are connected to the GDON[7:0] pins of the AB macro. Note that the CFG_GDx
parameters/generics settings affect whether or not the GDON[7:0] register bits are used.
(Refer to the Fusion datasheet for further information.)
Table 23 • ADC Control Register 5 (high-order)
Bits
Name
7:2
Reserved
1:0
GDON[9:8]
Function
Not used
Gate Driver Enables
These bits are connected to the GDON9 and GDON8 pins of the AB macro. Note that the CFG_GDx
parameters/generics settings affect whether or not the GDON[9:8] register bits are used.
(Refer to the Fusion datasheet for further information.)
Table 24 • ADC Status Register (low-order)
Bits
Name
7:0
RESULT[7:0]
Function
ADC Result (low-order)
These bits come from the RESULT[7:0] bits of the AB macro.
(Refer to the Fusion datasheet for further information.)
14
v2.0
CoreAI
Table 25 • ADC Status Register (high-order)
Bits
7
Name
CALIBRATE
Function
ADC Calibrate
1 – The ADC is busy performing its calibration.
0 – The ADC is calibrated.
(Refer to the Fusion datasheet for further information.)
6
SAMPLE
ADC Sample
1 – The ADC is sampling the selected analog input.
0 – Normal (no operation or the ADC has finished the sampling phase)
(Refer to the Fusion datasheet for further information.)
5
BUSY
ADC Busy
1 – The ADC is busy performing an analog-to-digital conversion.
0 – The ADC is not busy.
(Refer to the Fusion datasheet for further information.)
4
DATAVALID
ADC Data Valid
1 – The ADC contains valid data from an analog-to-digital conversion on the RESULT[11:0] outputs.
0 – Normal (no operation or current conversion continues)
(Refer to the Fusion datasheet for further information.)
3:0
RESULT[11:8]
ADC Result (high-order)
These bits come from the RESULT[11:8] bits of the AB macro.
(Refer to the Fusion datasheet for further information.)
Table 26 • Read FIFO Data Output Register
Bits
Name
7:0
DOUT[7:0]
Function
Read FIFO Data Output
If CoreAI is used in 8-bit APB read/write mode, the read FIFO must be read twice to retrieve one
ADC sample of result data (two bytes); in this case, the low-order byte would be read first and the
high-order byte second. Note also that in 8-bit APB read/write mode, the read FIFO will not become
empty until the last high-order byte has been read from the FIFO, i.e., an even number of reads
must occur. If CoreAI is used in 16-bit APB read/write mode, the read FIFO will be read as one 16-bit
word at once (with only the lower 12 bits being significant, since the ADC result has 12 bits of
resolution); in this case, DOUT[15:0] will appear on the PRDATA[15:0] output port, rather than
DOUT[7:0] appearing on PRDATA[7:0] as in 8-bit mode.
v2.0
15
CoreAI
Table 27 • Read FIFO Status Register
Bits
Name
7:4
Reserved
3
AEMPTY
Function
Not used
Read FIFO Almost Empty
1 – The read FIFO is almost empty (based on the value of the USE_RDFIFO_AEVAL parameter/
generic).
0 – The read FIFO is not almost empty.
2
EMPTY
Read FIFO Empty
1 – The read FIFO is empty.
0 – The read FIFO is not empty.
1
AFULL
Read FIFO Almost Full
1 – The read FIFO is almost full (based on the value of the USE_RDFIFO_AFVAL parameter/generic).
0 – The read FIFO is not almost full.
0
FULL
Read FIFO Full
1 – The read FIFO is full.
0 – The read FIFO is not full.
Table 28 • Interrupt Enable Register (low-order)
Bits
7
6:0
Name
Reserved
INTEN[6:0]
Function
Not used
Low-Order Interrupt Enables
Each of these bits is ANDed with each of the bits in the INT[6:0] register to contribute to the ORed
INTERRUPT output. To mask the contribution of the corresponding bit in the INT[6:0] register, set
that bit to 0; to enable the contribution, set that bit to 1. Note that the INTEN[6:0] bits only mask
what appears on the INTERRUPT output and that the INT[6:0] register bits will always be active to
reflect current interrupt source conditions.
Table 29 • Interrupt Enable Register (high-order)
Bits
Name
7:0
INTEN[14:7]
Function
High-Order Interrupt Enables
Each of these bits is ANDed with each of the bits in the INT[14:7] register to contribute to the ORed
INTERRUPT output. To mask the contribution of the corresponding bit in the INT[14:7] register, set
that bit to 0; to enable the contribution, set that bit to 1. Note that the INTEN[14:7] bits only mask
what appears on the INTERRUPT output and that the INT[14:7] register bits will always be active to
reflect current interrupt source conditions.
16
v2.0
CoreAI
Table 30 • Interrupt Status Register (low-order)
Bits
Name
Function
7
Reserved
Not used
6
INT[6]
RTC Match Rising Edge – If 1, the RTCMATCH output has transitioned high, indicating that the RTC
has reached the desired count.
5
INT[5]
ACM Read Done – If 1, an ACM read cycle has completed and valid data can be read from the
ACM DATA register.
4
INT[4]
ACM Write Done – If 1, an ACM write cycle has completed and valid data has been written into the
AB macro.
3
INT[3]
DATAVALID Rising Edge – If 1, the DATAVALID signal from the AB block has transitioned high,
indicating that valid converted data from the ADC is available on the RESULT[11:0] output port
from the AB block.
2
INT[2]
BUSY Rising Edge – If 1, the BUSY signal from the AB block has transitioned high, indicating that
the ADC has begun an analog-to-digital conversion and is now busy performing that conversion.
1
INT[1]
CALIBRATE Falling Edge – If 1, the CALIBRATE signal from the AB block has transitioned low,
indicating that the ADC has finished its calibration procedure.
0
INT[0]
CALIBRATE Rising Edge – If 1, the CALIBRATE signal from the AB block has transitioned high,
indicating that the ADC has started its calibration procedure.
Table 31 • Interrupt Status Register (high-order)
Bits
Name
Function
7
INT[14]
Read FIFO Almost Empty Rising Edge – If 1, the Almost Empty flag from the read FIFO has
transitioned high, indicating that it is almost empty.
6
INT[13]
Read FIFO Almost Empty Falling Edge – If 1, the Almost Empty flag from the read FIFO has
transitioned low, indicating that it is no longer almost empty.
5
INT[12]
Read FIFO Empty Rising Edge – If 1, the Empty flag from the read FIFO has transitioned high,
indicating that it is now empty.
4
INT[11]
Read FIFO Empty Falling Edge – If 1, the Empty flag from the read FIFO has transitioned low,
indicating that it is no longer empty.
3
INT[10]
Read FIFO Almost Full Rising Edge – If 1, the Almost Full flag from the read FIFO has transitioned
high, indicating that it is almost full.
2
INT[9]
Read FIFO Almost Full Falling Edge – If 1, the Almost Full flag from the read FIFO has transitioned
low, indicating that it is no longer almost full.
1
INT[8]
Read FIFO Full Rising Edge – If 1, the Full flag from the read FIFO has transitioned high, indicating
that it is now full.
0
INT[7]
Read FIFO Full Falling Edge – If 1, the Full flag from the read FIFO has transitioned low, indicating
that it is no longer full.
v2.0
17
CoreAI
ACM Interface
The internal address map of the ACM is shown in
Table 32.
The ACM interface is used to configure the analog quads
and RTC within the AB macro. Various features of the
analog quads need to be set prior to correct operation of
the ADC, including the pre-scaler circuits in each of the
AV, AC, and AT analog input ports that will be accessed
in the user’s design. The SmartGen software, included
with Libero IDE, can be used to configure the various
pre-scaler settings for each quad, as well as the functions
used (voltage monitor, current monitor, temperature
monitor, gate-driver output driver strengths, etc.).
Consult the Fusion datasheet for details on how each
pre-scaler should be set, relative to the design-specific
voltage, current, or temperature ranges used.
Note that the ACM must operate with a clock frequency
that is less than or equal to 10 MHz; to achieve this
requirement, the user must set the clock-divider
appropriately via the ACM_CLK_DIV parameter/generic.
For example, if the system clock frequency (PCLK) is
50 MHz, ACM_CLK_DIV can be set to 3, which would
generate an ACM clock frequency of 50/(23) = 6.25 MHz.
ACM reads and writes are synchronized to the internally
generated ACM clock. Since the ACM clock is operating
at a lower frequency than the system clock (PCLK) used
by CoreAI, various status and interrupt status registers
have been implemented to indicate when ACM read and
write accesses are busy or completed (see Table 10 on
page 12 and Table 30 on page 17).
Table 32 • ACM Address Map (Analog Quads and RTC)*
PADDR[4:0]
Name
Description
Associated Peripheral
–
Reserved
Unused
0x01
AQ0
Byte 0 (AV0 control)
Analog Quad
0x02
AQ0
Byte 1 (AC0 control)
Analog Quad
0x03
AQ0
Byte 2 (AG0 control)
Analog Quad
0x04
AQ0
Byte 3 (AT0 control)
Analog Quad
0x05
AQ1
Byte 0 (AV1 control)
Analog Quad
0x06
AQ1
Byte 1 (AC1 control)
Analog Quad
0x07
AQ1
Byte 2 (AG1 control)
Analog Quad
0x08
AQ1
Byte 3 (AT1 control)
Analog Quad
…
…
Analog Quad
0x25
AQ9
Byte 0 (AV9 control)
Analog Quad
0x26
AQ9
Byte 2 (AC9 control)
Analog Quad
0x27
AQ9
Byte 2 (AG9 control)
Analog Quad
0x28
AQ9
Byte 3 (AT9 control)
Analog Quad
0x29
–
Reserved
Unused
0x30
–
Reserved
Unused
…
…
…
Unused
0x3E
–
Reserved
Unused
0x00
Analog Quad 0
Analog Quad 1
…
Analog Quad 9
Note: *Address values are given in hexadecimal format.
18
v2.0
CoreAI
Table 32 • ACM Address Map (Analog Quads and RTC)* (Continued)
PADDR[4:0]
Name
Description
Associated Peripheral
0x3F
–
Reserved
Unused
0x40
COUNTER0
Counter bits 7:0
RTC
0x41
COUNTER1
Counter bits 15:8
RTC
0x42
COUNTER2
Counter bits 23:16
RTC
0x43
COUNTER3
Counter bits 31:24
RTC
0x44
COUNTER4
Counter bits 39:32
RTC
0x45
–
Reserved
Unused
0x46
–
Reserved
Unused
0x47
–
Reserved
Unused
0x48
MATCHREG0
Match register bits 7:0
RTC
0x49
MATCHREG1
Match register bits 15:8
RTC
0x4A
MATCHREG2
Match register bits 23:16
RTC
0x4B
MATCHREG3
Match register bits 31:24
RTC
0x4C
MATCHREG4
Match register bits 39:32
RTC
0x4D
–
Reserved
Unused
0x4E
–
Reserved
Unused
0x4F
–
Reserved
Unused
0x50
MATCHBITS0
Individual match bits 7:0
RTC
0x51
MATCHBITS1
Individual match bits 15:8
RTC
0x52
MATCHBITS2
Individual match bits 23:16
RTC
0x53
MATCHBITS3
Individual match bits 31:24
RTC
0x54
MATCHBITS4
Individual match bits 39:32
RTC
0x55
–
Reserved
Unused
0x56
–
Reserved
Unused
0x57
–
Reserved
Unused
0x58
CTRL_STAT
Control (write) / Status (read) register bits 7:0
RTC
0x59
TEST_REG
Test register(s)
RTC
0x60
–
Reserved
Unused
0x61
–
Reserved
Unused
…
…
…
Unused
0xFF
–
Reserved
Unused
Real-Time Counter
Note: *Address values are given in hexadecimal format.
v2.0
19
CoreAI
ACM Writes
2. Write the desired ACM address to the ACM
Address register.
An example of writing data into the ACM is illustrated in
Figure 5. The steps for writing information into the AB
block via the ACM are as follows:
3. Write the desired ACM data to the ACM Data
register.
4. Keep reading the ACM Control/Status register
until CoreAI is not busy processing the ACM
write.
1. Read the ACM Control/Status register to make
sure that CoreAI is not busy processing an ACM
read or write.
PCLK
PADDR[4:0]
ACMCtrlStat
ACMAddr
ACMData
ACMCtrlStat
PWRITE
PSEL
PENABLE
PWDATA[7:0]
ACMADDR[7:0]
PRDATA[7:0]
ACMDATA[7:0]
00
08
00
Note: 8-bit APB reads and writes are shown.
Figure 5 • ACM Write Procedure
ACM Reads
An example of reading data from the ACM is illustrated
in Figure 6. The steps for reading information from the
AB block via the ACM are as follows:
1. Read the ACM Control/Status register to make
sure that CoreAI is not busy processing an ACM
read or write.
2. Write the desired ACM address to the ACM
Address register.
3. Write a logic 1 to the ACMRDSTART bit of the
ACM Control/Status register.
4. Keep reading the ACM Control/Status register
until CoreAI is not busy processing the ACM read.
5. Read the ACM Data register to read the byte of
ACM data that is now available from the AB
block.
PCLK
PADDR[4:0]
ACMCtrlStat
ACMAddr
ACMCtrlStat
ACMData
PWRITE
PSEL
PENABLE
ACMADDR[7:0]
PWDATA[7:0]
PRDATA[7:0]
02
00
04
Note: 8-bit APB reads and writes are shown.
Figure 6 • ACM Read Procedure
20
v2.0
00
ACMDATA[7:0]
CoreAI
RTC Operation
ACM interface address map listed in Table 32 on page 18.
Control of the RTC is primarily accomplished via writes to
the RTC CTRL_STAT (Control/Status) register at ACM
address 0x58 (88), which is listed in Table 33. Status
information is primarily obtained by reading the same
register.
For detailed data on the connection and operation of
the 40-bit real-time counter block within the AB macro,
refer to the Fusion datasheet.
The SmartGen software can be used to configure the
RTC. The internal registers of the RTC are accessed via the
Table 33 • RTC Control/Status Register
Bits
Name
Function
7
rtc_rst
RTC Reset: Writing logic 1 to this bit causes an RTC reset.1 Writing logic 0 to this bit will allow
synchronous removal of reset after two ACM_CLK cycles if VCC33UP = 1.2
6
cntr_en
Counter Enable: Writing logic 1 to this bit will enable the counter if the RTC is not in reset. After
reset is removed and cntr_en = 1, 64 RTCCLK positive edges (one-half of the pre-scaler division
factor) will elapse before the counter is incremented.3 A logic 0 in this bit resets the pre-scaler and
therefore suspends incrementing the counter, but the counter is not reset. Before writing to the
COUNTER registers, the counter must be disabled.
5
vr_en_mat
Voltage Regulator Enable on Match: Writing logic 1 to this bit will allow the RTCMATCH output
port to transition to logic 1 when a match occurs between the 40-bit counter and the 40-bit match
register. Logic 0 forces RTCMATCH to logic 0 to prevent enabling the voltage regulator from the
RTC.
4:3
xt_mode[1:0]
Crystal Oscillator Mode: These bits control the RTCXTLMODE[1:0] output ports that are connected
to the RTCMODE[1:0] input pins of the crystal oscillator pad. For 32 kHz crystal operation, this
should be set to "01".
2
rst_cnt_omat
Reset Counter on Match: Writing logic 1 to this bit allows the counter to clear itself when a match
occurs. In this situation, the 40-bit counter clears on the next rising edge of the pre-scaled clock,
approximately 4 ms after the match occurs (the pre-scaled clock toggles at a rate of 256 Hz, given
a 32.768 kHz external crystal). Writing logic 0 to this bit allows the counter to increment
indefinitely while still allowing match events to occur.
1
rstb_cnt
Counter Reset: Writing logic 0 to this bit resets the 40-bit counter value to 0. Writing logic 1 allows
the counter to count.
0
xtal_en
Crystal Oscillator Enable: This bit controls the RTCXTLSEL output port that is connected to the
SELMODE input pin of the crystal oscillator. If a logic 0 is written to this bit, only the FPGA fabric
can be used to control the crystal oscillator EN and MODE[1:0] inputs. If a logic 1 is written to this
bit, only the RTC can be used to control the RTCXTLSEL and RTCMODE[1:0] inputs of the crystal
oscillator. This bit must be set to 1 to allow the RTC counter to function if the 1.5 V supply is off.
Notes:
1. Reset of all RTC states (except this Control/Status register) occurs asynchronously if VCC33UP = 0 or CTRL_STAT bit 7 (rtc_rst) is
written to 1.
2. Reset is removed synchronously after 2 rising edges of the ACM_CLK, following both VCC33UP = 1 and rtc_rst = 0.
3. Counter will first increment on the 64th rising edge of RTCCLK after all of the following are true: reset is removed, the rstb_cnt bit
is set to 1, and the cntr_en bit is set to 1; it will then increment every 128 RTCCLK cycles.
v2.0
21
CoreAI
ADC Operation
(internal or external), mode selection
resolution), and clock divider settings.
Control of the ADC within the AB macro in CoreAI is
accomplished by APB reads and writes. After a power-up
reset condition, the ADC will come out of its reset state
and commence with its internal calibration sequence.
When this calibration sequence has finished, the ADC
will be ready to use for conversions. Read the INT[1:0]
register bits to obtain status information relevant to the
ADC calibration.
The user must configure the analog quads
appropriately via the ACM interface to match the
required design-specific voltage, current, and
temperature ranges prior to performing ADC
conversions; failure to do so may result in damage to
the Fusion device. The SmartGen software can be used to
configure the analog quads and RTC.
ADC Control
A typical analog-to-digital conversion is shown starting
in Figure 7 and ending in Figure 8 on page 23. The steps
for performing an ADC conversion are as follows:
1. Read the ADC Status register to ensure that the ADC
is not busy calibrating or performing a conversion.
2. Write the desired ADC settings to ADC Control
register 1, including the voltage reference selection
3. Write the desired ADC settings to ADC Control
register 2, including the sample time control and
channel number to sample (1 of 32).
4. Set the Start Conversion bit to begin the
conversion process.
5. If a current or temperature monitor operation is
used on a corresponding AC or AT input pin, a write
must be done to set the corresponding current or
temperature monitor strobe high in ADC Control
register 3 or ADC Control register 4, respectively.
Refer to the Fusion datasheet for details on
external component connection requirements for
current and temperature monitoring.
6. Keep reading the high-order ADC Status register
until the ADC is not busy performing a conversion.
7. If a current or temperature monitor operation has
completed using a corresponding AC or AT input
pin, a write must be done to set the corresponding
current or temperature monitor strobe low in ADC
Control register 3 or ADC Control register 4,
respectively.
8. Read the low-order ADC Status register to obtain
the lower 8 bits of the resulting ADC conversion
data (the upper 4 bits of conversion data have
already been read from the high-order ADC Status
register).
ADC Conversion Starts
PCLK
PADDR[4:0]
ADCStat(hi)
ADCCtrl1(lo) ADCCtrl1(hi) ADCCtrl2(lo) ADCCtrl2(hi)
ADCStat(hi)
PWRITE
PSEL
PENABLE
00
PWDATA[7:0]
PRDATA[7:0]
01
08
00
22
11
60
Note: 8-bit APB reads and writes are shown.
Figure 7 • ADC Start of Conversion
v2.0
(ADC
CoreAI
ADC Conversion Ends
PCLK
PADDR[4:0]
ADCStat(hi)
ADCStat(lo)
PWRITE
PSEL
PENABLE
PWDATA[7:0]
PRDATA[7:0]
20
15
55
Note: 8-bit APB reads and writes are shown.
Figure 8 • ADC End of Conversion
ADC Result Read FIFO
Note that although the ADC conversion results are
stored as one 16-bit word, the four upper bits of this 16bit word are reserved for possible future use. Since there
is no channel information associated with each ADC
conversion word, it is up to the user to maintain
temporal coherency between conversions and resulting
data.
An optional read FIFO, capable of holding up to 256
analog-to-digital conversions, is instantiated in CoreAI
when the USE_RDFIFO parameter/generic is set to 1. The
controlling element that is connected to CoreAI (internal
or external microprocessor or microcontroller, or custom
FPGA logic) can read resulting ADC conversions from this
FIFO when desired. Resulting ADC conversion data is
always written into the FIFO 12 bits at once, regardless of
the ADC resolution (8-, 10-, or 12-bit), and is MSBjustified so that the resulting values are always of the
same order of magnitude. The steps for reading resulting
ADC conversion data from the read FIFO are as follows:
Interrupt Logic
Although polling operations have been described to
control the ACM and ADC, wherein status registers are
periodically read (polled), the INTERRUPT output may be
connected to a microprocessor or microcontroller to
indicate similar events (e.g., ACM reads and writes
completing, ADC calibration events, read FIFO events,
etc.). In this case, interrupt service routines may be
written in software to determine what actions, if any,
should be taken for each of the interrupt events. Any or
all interrupt events can be disabled by writing logic 0
values to the INTEN[14:0] register bits to mask the effect
of each of the interrupt sources; it is the responsibility of
the microprocessor/microcontroller software developer
to determine what should or should not be masked.
1. Read the Read FIFO Status register to check if
there is data in the FIFO (not empty).
2. If the APB_16BIT_DATA parameter/generic is set to
0 (8-bit mode), read the Read FIFO Data Output
register twice in a row to retrieve the lower 8 bits
then the upper 4 bits of ADC conversion data. If
the APB_16BIT_DATA parameter/generic is set to 1
(16-bit mode), read the Read FIFO Data Output
register once to retrieve all 12 bits of ADC
conversion data.
3. Repeat steps 1 and 2 until the Read FIFO is empty.
v2.0
23
CoreAI
Ordering Information
Order CoreAI through your local Actel sales representative. Use the following naming convention when ordering:
CoreAI-XX, where XX is listed in Table 34.
Table 34 • Ordering Codes
Traditional (FTP) Delivery
CoreConsole Delivery
EV
Evaluation version
Evaluations included with CoreConsole
SN
Single use netlist
OC
Obfuscated RTL – 1 year license
AN
Multiple use netlist
OM
Obfuscated RTL – multiple use license
SR
Single use RTL
RC
RTL source – 1 year license
AR
Multiple use RTL
RM
RTL source – multiple use license
UR
Unrestricted technology (on request)
UG
Upgrade
M
Maintenance
Datasheet Categories
In order to provide the latest information to designers, some datasheets are published before data has been fully
characterized. Datasheets are designated as "Product Brief," "Advanced," and "Production." The definitions of these
categories are as follows:
Product Brief
The product brief is a summarized version of an advanced or production datasheet containing general product
information. This brief summarizes specific device and family information for unreleased products.
Advanced
This datasheet version contains initial estimated information based on simulation, other products, devices, or speed
grades. This information can be used as estimates, but not for production.
Unmarked (production)
This datasheet version contains information that is considered to be final.
24
v2.0
Actel and the Actel logo are registered trademarks of Actel Corporation.
All other trademarks are the property of their owners.
www.actel.com
Actel Corporation
Actel Europe Ltd.
Actel Japan
www.jp.actel.com
Actel Hong Kong
www.actel.com.cn
2061 Stierlin Court
Mountain View, CA
94043-4655 USA
Phone 650.318.4200
Fax 650.318.4600
Dunlop House, Riverside Way
Camberley, Surrey GU15 3YL
United Kingdom
Phone +44 (0) 1276 401 450
Fax +44 (0) 1276 401 490
EXOS Ebisu Bldg. 4F
1-24-14 Ebisu Shibuya-ku
Tokyo 150 Japan
Phone +81.03.3445.7671
Fax +81.03.3445.7668
Suite 2114, Two Pacific Place
88 Queensway, Admiralty
Hong Kong
Phone +852 2185 6460
Fax +852 2185 6488
51700066-0/3.06