STANLEY MU20-5105 Single color / light bar module Datasheet

MU20 Series
Single Color / Light Bar Module
Features
Light emitting surface (Outer size)
Product features
5 x 9 mm (6 x 10 mm) (L x W)
・Single Color (Green, Yellow Green, Orange or Red)
・Lead–free soldering compatible
・RoHS compliant
Peak wavelength
Green
Yellow Green
Orange
Red
Die materials
Green, Yellow Green : GaP
Orange
: GaAsP
Red
: GaAlAs
Soldering methods
TTW (Through The Wave) soldering and manual soldering
Soldering methods
More than 2kV(HBM)
Packing
Plastic bag
: 555 nm
: 570 nm
: 605 nm
: 660 nm
Recommended Applications
Electric Household Appliances, OA/FA, Other General Applications
2012.11.19
Page 1
MU20 Series
Single Color / Light Bar Module
Color and Luminous Intens ity
L uminous Inte nsity
P a rt No.
Ma te ria l E mitte d Color
MU20-5101
MU20-5105
MU20-4101
MU20-4105
MU20-3101
MU20-3105
MU20-2101
MU20-2105
Ga P
Gre e n
Ga P
Ga P
Ye llow Gre e n
Ga P
Ga AsP
Ora ng e
Ga AsP
Ga AlAs
Re d
Ga AlAs
Re sin Color
Gre e n
Milky White
Ye llow
Milky White
Ora ng e
Milky White
Re d
Milky White
Numbe r of
Chips
Iv (mc d)
MIN.
2
2
4
4
3
3
4
4
T YP .
4
4
8
8
6
6
8
8
IF
20
20
20
20
20
20
20
20
1
1
1
1
1
1
1
1
Abs olute Maximum R atings
(Ta=25℃)
Absolute Ma x imum Ra ting s
Ite m
S ymbol
P ow e r Dissipa tion
Pd
62.5
75
62.5
60
mW
IF
25
30
25
30
mA
F orwa rd Curre nt
※1
5101
5105
4101
4105
3101 3105 2101 2105
Unit
IF R M
60
60
60
60
mA
⊿ IF
0.33
0.40
0.33
0.40
0.80
0.80
0.80
0.80
Re ve rse Volta g e
⊿ IF R M
VR
mA/℃
mA/℃
4
4
4
4
V
Ope ra ting Te mpe ra ture
T opr
S tora g e T e mpe ra ture
T s tg
P ulse F orwa rd Curre nt
De ra ting
(T a =25℃ or hig he r)
-40~ +85
-40~ +85
℃
℃
※ 1 IF R M Me a sure me nt condition : P ulse Width ≦ 2ms, Duty ≦ 1/5
E lectro- Optical Characteris tics
Ite m
Conditions
5101
5105
4101
4105
3101 3105 2101 2105
Unit
T YP .
2.2
2.1
2.2
1.7
MAX .
2.5
2.5
2.5
2.0
IR
MAX .
100
100
100
100
λp
T YP .
555
570
605
660
μA
nm
⊿λ
T YP .
30
30
30
30
nm
IF =20mA
VF
Re ve rse Curre nt
V R =4V
2012.11.19
Cha ra cte ristics
S ymbol
F orw a rd Volta ge
P e a k Wa ve le ng th IF =20mA
S pe ctra l L ine Half
IF =20mA
Width
(Ta=25℃)
V
Page 2
MU20 Series
Single Color / Light Bar Module
Technical Data(5101/5105)
Forward Voltage vs. Forward Current
Ambient Temperature vs. Forward Voltage
Forward Voltage VF(V)
Forward Current IF(mA)
Condition : Ta = 25℃
Forward Voltage VF(V)
Ambient Temperature : Ta(℃)
Forward Current vs. Relative Intensity
Ambient Temperature vs. Relative Intensity
Condition : IF=20mA
Relative Intensity
Relative Intensity
Condition : Ta = 25℃
Forward Current IF(mA)
2012.11.19
Ambient Temperature : Ta(℃)
Page 3
MU20 Series
Single Color / Light Bar Module
Technical Data(5101/5105)
Power Dissipation vs. Ambient Temperature
Derating
Power Dissipation : Pd (mW)
Maximum Forward Current : IF MAX. (mA)
Ambient Temperature vs. Maximum Forward Current
Repetition Frequency : f ≧ 100Hz
Ambient Temperature : Ta(℃)
Ambient Temperature : Ta(℃)
Pulse Width vs. Maximum Tolerable Peak Current
Dynamic Drive Rating
Duty cycle vs. Maximum Forward Current
Condition : Ta = 25℃
IF peak Max./IF DC MAX.
Maximum Forward Current : IF MAX. (mA)
Condition : Ta = 25℃
Pulse Width : tw (μs)
2012.11.19
Duty (%)
Page 4
MU20 Series
Single Color / Light Bar Module
Technical Data(4101/4105)
Forward Voltage vs. Forward Current
Ambient Temperature vs. Forward Voltage
Forward Voltage VF(V)
Forward Current IF(mA)
Condition : Ta = 25℃
Forward Voltage VF(V)
Ambient Temperature : Ta(℃)
Forward Current vs. Relative Intensity
Ambient Temperature vs. Relative Intensity
Condition : IF=20mA
Relative Intensity
Relative Intensity
Condition : Ta = 25℃
Forward Current IF(mA)
2012.11.19
Ambient Temperature : Ta(℃)
Page 5
MU20 Series
Single Color / Light Bar Module
Technical Data(4101/4105)
Power Dissipation vs. Ambient Temperature
Derating
Power Dissipation : Pd (mW)
Maximum Forward Current : IF MAX. (mA)
Ambient Temperature vs. Maximum Forward Current
Repetition Frequency : f ≧ 100Hz
Ambient Temperature : Ta(℃)
Ambient Temperature : Ta(℃)
Pulse Width vs. Maximum Tolerable Peak Current
Dynamic Drive Rating
Duty cycle vs. Maximum Forward Current
Condition : Ta = 25℃
IF peak Max./IF DC MAX.
Maximum Forward Current : IF MAX. (mA)
Condition : Ta = 25℃
Pulse Width : tw (μs)
2012.11.19
Duty (%)
Page 6
MU20 Series
Single Color / Light Bar Module
Technical Data(3101/3105)
Forward Voltage vs. Forward Current
Ambient Temperature vs. Forward Voltage
Forward Voltage VF(V)
Forward Current IF(mA)
Condition : Ta = 25℃
Forward Voltage VF(V)
Ambient Temperature : Ta(℃)
Forward Current vs. Relative Intensity
Ambient Temperature vs. Relative Intensity
Condition : IF=20mA
Relative Intensity
Relative Intensity
Condition : Ta = 25℃
Forward Current IF(mA)
2012.11.19
Ambient Temperature : Ta(℃)
Page 7
MU20 Series
Single Color / Light Bar Module
Technical Data(3101/3105)
Power Dissipation vs. Ambient Temperature
Derating
Power Dissipation : Pd (mW)
Maximum Forward Current : IF MAX. (mA)
Ambient Temperature vs. Maximum Forward Current
Repetition Frequency : f ≧ 100Hz
Ambient Temperature : Ta(℃)
Ambient Temperature : Ta(℃)
Pulse Width vs. Maximum Tolerable Peak Current
Dynamic Drive Rating
Duty cycle vs. Maximum Forward Current
Condition : Ta = 25℃
IF peak Max./IF DC MAX.
Maximum Forward Current : IF MAX. (mA)
Condition : Ta = 25℃
Pulse Width : tw (μs)
2012.11.19
Duty (%)
Page 8
MU20 Series
Single Color / Light Bar Module
Technical Data(2101/2105)
Forward Voltage vs. Forward Current
Ambient Temperature vs. Forward Voltage
Forward Voltage VF(V)
Forward Current IF(mA)
Condition : Ta = 25℃
Forward Voltage VF(V)
Ambient Temperature : Ta(℃)
Forward Current vs. Relative Intensity
Ambient Temperature vs. Relative Intensity
Condition : IF=20mA
Relative Intensity
Relative Intensity
Condition : Ta = 25℃
Forward Current IF(mA)
2012.11.19
Ambient Temperature : Ta(℃)
Page 9
MU20 Series
Single Color / Light Bar Module
Technical Data(2101/2105)
Power Dissipation vs. Ambient Temperature
Derating
Power Dissipation : Pd (mW)
Maximum Forward Current : IF MAX. (mA)
Ambient Temperature vs. Maximum Forward Current
Repetition Frequency : f ≧ 100Hz
Ambient Temperature : Ta(℃)
Ambient Temperature : Ta(℃)
Pulse Width vs. Maximum Tolerable Peak Current
Dynamic Drive Rating
Duty cycle vs. Maximum Forward Current
Condition : Ta = 25℃
IF peak Max./IF DC MAX.
Maximum Forward Current : IF MAX. (mA)
Condition : Ta = 25℃
Pulse Width : tw (μs)
2012.11.19
Duty (%)
Page 10
MU20 Series
Single Color / Light Bar Module
Package Dimensions
(Unit: mm)
(Tolerance:±0.25 mm)
● ※ mark : The measure of lead root
2012.11.19
Page 11
MU20 Series
Single Color / Light Bar Module
TTW (Through The Wave) soldering Conditions
Pre-heating
100 ℃
60 s
(MAX.) Resin surface temperature
(MAX.)
Solder Bath Temp.
265 ℃
(MAX.)
Dipping Time
Position
5 s
(MAX.)
At least 3.0 mm away from the root of lead
1) The dip soldering process shall be 2 times maximum.
2) The product shall be cooled to normal temperature before the second dipping process.
Manual Soldering Conditions
Iron tip temp.
Soldering time and frequency
Position
2012.11.19
360 ℃
(MAX.)
(MAX.)
3 s
2 times (MAX.)
At least 3.0 mm away from the root of lead
Page 12
MU20 Series
Single Color / Light Bar Module
Reliability Testing Result
Reliability Testing Result Applicable Standard
Room Temp.
Operating Life
Resistance to
Soldering Heat
EIAJ ED4701/100(101)
EIAJ ED4701/300(302)
Temperature Cycling
EIAJ ED4701/100(105)
Wet High Temp.
Storage Life
High Temp.
Storage Life
Low Temp.
Storage Life
Lead Tension
Vibration,
Variable Frequency
Lead Bend
Shock
EIAJ ED4701/100(103)
EIAJ ED4701/200(201)
EIAJ ED4701/200(202)
EIAJ ED4701/400(401)
EIAJ ED4701/400(403)
EIAJ ED4701/400(401)
JIS C 7201
A-8
Testing Conditions
Duration
Ta = 25℃, IF = Maxium Rated Current
Failure
1,000 h
0/10
10s
0/10
Minimum Rated Storage Temperature(30min)
~Normal Temperature(15min)
~Maximum Rated Storage Temperature(30min)
~Normal Temperature(15min)
5 cycles
0/10
Ta = 60±2℃, RH = 90±5%
1,000 h
0/10
Ta = Maximum Rated Storage Temperature
1,000 h
0/10
Ta = Minimum Rated Storage Temperature
1,000 h
0/10
10s
0/10
2h
0/10
Twice
0/10
3 times
0/10
260±5℃, 3mm from package base
5N,1time
2
98.1m/s (10G), 100 ~ 2KHz sweep for 20min.,
XYZ each direction
2.5N, 0°←→ 90°
It falls on wood engraving from height of 75cm.
Failure Criteria
Items
Symbols
Conditions
Failure criteria
Luminous Intensity
Iv
IF=20mA
Testing Min. Value < Spec. Min. Value x 0.5
Forward Voltage
VF
IF=20mA
Testing Max. Value ≧ Spec. Max. Value x 1.2
Reverse Current
IR
VR=4V
Testing Max. Value ≧ Spec. Max. Value x 2.5
Cosmetic Appearance
-
-
Occurrence of notable decoloration,
deformation and cracking
2012.11.19
Page 13
MU20 Series
Single Color / Light Bar Module
Special Notice to Customers Using the Products and
Technical Information Shown in This Data Sheet
1) The technical information shown in the data sheets are limited to the typical characteristics and circuit
examples of the referenced products. It does not constitute the warranting of industrial property nor the
granting of any license.
2) For the purpose of product improvement, the specifications, characteristics and technical data described in
the data sheets are subject to change without prior notice. Therefore it is recommended that the most
updated specifications be used in your design.
3) When using the products described in the data sheets, please adhere to the maximum ratings for operating
voltage, heat dissipation characteristics, and other precautions for use. We are not responsible for any
damage which may occur if these specifications are exceeded.
4) The products that have been described to this catalog are manufactured so that they will be used for the
electrical instrument of the benchmark (OA equipment, telecommunications equipment, AV machine, home
appliance and measuring instrument).
The application of aircrafts, space borne application, transportation equipment, medical equipment and
nuclear power control equipment, etc. needs a high reliability and safety, and the breakdown and the wrong
operation might influence the life or the human body. Please consult us beforehand if you plan to use our
product for the usages of aircrafts, space borne application, transportation equipment, medical equipment
and nuclear power control equipment, etc. except OA equipment, telecommunications equipment, AV
machine, home appliance and measuring instrument.
5) In order to export the products or technologies described in this data sheet which are under the
“Foreign Exchange and Foreign Trade Control Law,” it is necessary to first obtain an export permit from the
Japanese government.
6) No part of this data sheet may be reprinted or reproduced without prior written permission from Stanley
Electric Co., Ltd.
7) The most updated edition of this data sheet can be obtained from the address below:
http://www.stanley-components.com
2012.11.19
Page 14