MPD MPV4080S Pv power, 40w 200 - 1500v input dc/dc con vert er Datasheet

MPV4080 Series
PV Power, 40W
200 - 1500V Input
DC/DC Converters
Electrical Specifications
Key Features:
• 40W Output Power
• 200 - 1500 VDC Input Range
• 4,000 VAC Isolation
• Input Under Volt Protection
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Start Voltage
Under Voltage Shutdown
Min.
200
180
170
200 VDC Input
800 VDC Input
1500 VDC Input
200 VDC Input
800 VDC Input
1500 VDC Input
• Output Over Volt Protection Input Current
• Short Circuit Protection
• -40°C to +70°C Operation
Conditions
Inrush Current
• >300 kHours MTBF
Typ.
Max.
1,500
195
185
320
80
42
Units
VDC
VDC
VDC
mA
30
80
150
Start-Up Time
A
2.0
S
Max.
Units
%
%
%
mV P - P
%/°C
%IOUT
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Temperature Coefficient
Over Power Protection
Output Short Circuit
Conditions
Min.
VIN = MIN to MAX
IOUT = 0% to 100%
See Note 1
Typ.
±2.0
±1.0
±1.0
150
±0.02
Autorecovery
120
Continuous (Autorecovery)
300
320
General
Parameter
Isolation Voltage
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions, See Note 2
Conducted Emissions, See Note 2
ESD
RS
EFT, See Note 3
Surge, See Note 4
CS
PFM
Conditions
60 Seconds
Min.
4,000
Typ.
Max.
65
Standard
Criteria
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
B
A
B
B
A
A
Units
VAC
kHz
Level
Class A
Class A
±6 kV/±8
10V/m
±2 kV
±1 kV
10 Vrms
10 A/m
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
-40
+25
-40
Free Air Convection
RH, Non-condensing
Ambient
Max.
+70
+85
Units
°C
°C
95
%
See Mechanical Drawings (Page 3)
Black, Flame Retardant, Non-Conductive Plastic (UL94-V0)
14.54 Oz (410g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
300
Typ.
Max.
Units
kHours
Conditions
Wave Soldering (5-10S)
Manual Soldering (3-5S)
Min.
255
350
Typ.
260
360
Max.
265
370
Units
Absolute Maximum Ratings
Parameter
Lead Temperature, See Note 5
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Output
Efficiency
Voltage
Current
(mA, Max)
Current
(mA, Min)
(%, Typ)
Over
Voltage Capacitive
Load
Protection (µF,
Max)
Fuse Rating
Slow-Blow
(mA)
Nominal
Range
(VDC)
MPV4080S-12RHI
800
200 - 1500
12.0
3,330
0.0
76
20.0
3,000
15A/1,500 VDC
MPV4080S-15RHI
800
200 - 1500
15.0
2,670
0.0
78
20.0
1,500
15A/1,500 VDC
MPV4080S-24RHI
800
200 - 1500
24.0
1,670
0.0
80
30.0
680
15A/1,500 VDC
(VDC Typ)
Notes:
1. To meet the specified ripple and noise levels, external capacitors are required. See the typical connection information on page three for recommended values. For more information, please
contact the factory.
2. All units will meet EN 55022 (CE/RE) class A with the input circuit shown in the “Typical Connection 2” diagram on page 3. Contact the factory for more information.
3. All units will meet EN 61000-4-4 (±2 kV) with the input circuit shown in the “Typical Connection 2” diagram on page 3. Contact the factory for more information.
4. All units will meet the requirements of EN 61000-4-5 (±1 kV), with the input circuit shown in the “Typical Connection 2” diagram on page 3. Contact the factory for more information.
5. Lead temperature is measured 1.5 mm from the case.
6. Operation at no load will not damage the units, however, they may not meet all specifications.
7. It is recommended that a fuse be used on the input of a power supply for protection. For the MPV4080-xxRHI series, a 15A/1,500 VDC slow blow should be used.
Derating Curve: Temperature
Derating Curve: Input Voltage
MicroPower Direct
•
(Input = 200 - 300 VDC)
(At 25ºC Ambient)
292 Page Street Ste D Stoughton, MA 02072
Derating Curve: Temperature (Input = 300 - 1500 VDC)
Derating Curve: Altitude
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Typical Connection 1
The diagram at left illustrates a typical connection of the
MPV4080S-xxRHI series. Output capacitors C9 and
C10 are filtering components. Capacitor C9 is a ceramic
and C10 is a high frequency, low resistance electrolytic.
The TVS is recommended to protect circuit components if
there is a fault with the converter.
The recommended component values are given in the
table below.
Typical Connection 2: With External EMC Components
Recommended values for components are:
Model
Number
LDM
LCM
C1, C2, C3, C4
C5, C6, C7, C8
R1, R2, R3, R4
C9
104k/275 VAC
47 μF/450V
1 M⍀/2W
1.0 μF/50V
MPV4080S-12RHI
MPV4080S-15RHI 330 µH/1A 7 mH/1A
C10
TVS
120 μF/25V SMBJ20A
68 μF/35V
MPV4080S-24RHI
For applications that require meeting higher EMC standards,
the circuit shown at left is recommended. Some notes on this
diagram (starting with the input circuit) are:
1. It is recommended that an external fuse be used. The
recommended fuse is 15A/1,500V.
2. Capacitors C1, C2, C3 and C4 are input filter components
(connected in series to achieve the required capacitance
level).
3. Capacitors C5, C6, C7 and C8 are also input filter components. Resistors R1, R2, R3 and R4 help to balance the
current across the capacitors.
4. Capacitor C9 is ceramic. This capacitor is used to filter
high frequency noise. A recommended value is given in
the table below.
5. Capacitor C10 is an electrolytic. A low ESR, high frequency
capacitor should be used.The recommended value is given
in the table below.
6. The output TVS will help protect system circuitry if the
converter fails. A recommended value is given in the table
below.
7. Derating on all capacitors should be 80% or more.
SMBJ30A
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
5
Function
+VIN
-VIN
+VOUT
-VOUT
No Connection
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]