AIMTEC AM40U-4812SH30IZ 40watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM40U-IZ
40Watt | DC-DC Converter
FEATURES:
•
•
•
•
•
Models
Single output
Model
AM40U-1203SIZ
AM40U-1205SIZ
AM40U-1212SIZ
AM40U-1215SIZ
AM40U-1224SIZ
AM40U-2403SIZ
AM40U-2405SIZ
AM40U-2412SIZ
AM40U-2415SIZ
AM40U-2424SIZ
AM40U-4803SIZ
AM40U-4805SIZ
AM40U-4812SIZ
AM40U-4815SIZ
AM40U-4824SIZ
AM40U-1203SH30IZ
AM40U-1205SH30IZ
AM40U-1212SH30IZ
AM40U-1215SH30IZ
AM40U-1224SH30IZ
AM40U-2403SH30IZ
AM40U-2405SH30IZ
AM40U-2412SH30IZ
AM40U-2415SH30IZ
AM40U-2424SH30IZ
AM40U-4803SH30IZ
AM40U-4805SH30IZ
AM40U-4812SH30IZ
AM40U-4815SH30IZ
AM40U-4824SH30IZ
Models
Dual output
Model
AM40U-1205DIZ
AM40U-1212DIZ
AM40U-1215DIZ
AM40U-2405DIZ
AM40U-2412DIZ
AM40U-2415DIZ
AM40U-4805DIZ
AM40U-4812DIZ
AM40U-4815DIZ
www.aimtec.com
F 051e R12.B
Wide Input 2:1 Range
1500 & 3000 VDC Isolation
Efficiency up to 87%
Regulated Output
Soft Start
•
•
•
•
Adjustable Output Voltage
Remote ON/OFF Function
Over Load, Voltage & Short Circuit Protection
Operating temperature -40oC to + 75oC
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
Isolation
(VDC)
Efficiency
(%)
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
36-75
3.3
5
12
15
24
3.3
5
12
15
24
3.3
5
12
15
24
7
7
3
2.3
1.5
7
7
3
2.3
1.5
7
7
3
2.3
1.5
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
85
85
85
85
85
86
86
86
86
86
86
86
87
87
87
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
Isolation
(VDC)
Efficiency
(%)
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
36-75
9-18
9-18
9-18
18-36
18-36
18-36
36-75
36-75
36-75
3.3
5
12
15
24
3.3
5
12
15
24
3.3
5
12
15
24
±5
±12
±15
±5
±12
±15
±5
±12
±15
7
7
3
2.3
1.5
7
7
3
2.3
1.5
7
7
3
2.3
1.5
±3.5
±1.5
±1.15
±3.5
±1.5
±1.15
±3.5
±1.5
±1.15
Tel: +1 514 620 2722
1 of 5
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
85
85
85
85
85
86
86
86
86
86
86
86
87
87
87
83
83
83
80
80
80
81
81
81
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40U-IZ
40Watt | DC-DC Converter
Models
Dual output (continued)
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
Isolation
(VDC)
Efficiency
(%)
AM40U-1205DH30IZ
9-18
±5
±3.5
3000
83
AM40U-1212DH30IZ
9-18
±12
±1.5
3000
83
AM40U-1215DH30IZ
9-18
±15
±1.15
3000
83
AM40U-2405DH30IZ
18-36
±5
±3.5
3000
80
AM40U-2412DH30IZ
18-36
±12
±1.5
3000
80
AM40U-2415DH30IZ
18-36
±15
±1.15
3000
80
AM40U-4805DH30IZ
36-75
±5
±3.5
3000
81
AM40U-4812DH30IZ
36-75
±12
±1.5
3000
81
AM40U-4815DH30IZ
36-75
±15
±1.15
3000
81
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Absolute Maximum Rating
On/Off control
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Nominal
Parameters
Ripple & Noise
Voltage adjustment range
Minimum Load Current
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
www.aimtec.com
F 051e R12.B
9-18
18-36
36-75
π(Pi) Network
12
24
48
Maximum
Units
VDC
25
50
100
ON –TTL High or Open ; OFF – TTL Low or short
Conditions
Typical
3 sec
500VDC
Output Specifications
Voltage accuracy
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Typical
12
24
48
1500 or 3000
>1000
Conditions
Maximum
Typical
Conditions
100% load
See chart below
Typical
2 of 5
VDC
MOhm
Units
%
%
% of Vin
%
%
%/oC
mV p-p
% p-p Vout
%
% of Max
Maximum
Units
95
% RH
250
-40 to +75
-55 to +115
100
45
Free air convection
Tel: +1 514 620 2722
Units
Maximum
±2
Zener diode clamp
>110 FL
Continuous
Auto-Restart
±0.5
Iout=25% to 100%
±0.5
Iout=25% to 100%
±2
±0.05
20MHz Bandwidth (5 & 3.3Vout)
80
All other output models
1
±5
25
VDC
KHz
o
C
o
C
o
C
o
C
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40U-IZ
40Watt | DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Maximum
50% load step change
Safety & EMC Specifications
Agency approvals
Typical
Nickel – coated Copper with nonconductive base
65
2.00 x 2.00 x 0.40 inches
50.81 x 50.81 10.20 mm
>1 500 000 hrs ( MIL-HDBK-217 F at +25 oC)
280
g
o
C
uS
Parameters
CE, (on 1500 VDC Isolation models only)
EN55022: 2010, class A
EN55024: 2010
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-6
IEC 61000-4-8
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Standards
Units
Pin Out Specifications
Pin
1000 & 3000VDC
Single
+V Input
-V Input
On/Off Control
No pin
+V Output
-V Output
Trim
1
2
3
4
5
6
7
Dual
+V Input
-V Input
On/Off Control
+V Output
Common
-V Output
Trim
Dimensions
10.16
(0.40)
Bottom View
5
2
6
3
7
10.16
(0.40)
50.80
(2.00)
5.08
(0.20)
1
10.16
(0.40)
22.86
(0.90)
4
10.16
(0.40)
50.80
(2.00)
45.70
(1.80)
Printed Face
Dimensions mm (inch)
Case Tolerance: ±0.25mm (±0.02inch)
Pin Length Tolerence: ±0.05mm (±0.002inch)
5.60
(0.22)
Side View
1.00
(0.04)
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40U-IZ
40Watt | DC-DC Converter
Trimming
Derating
Free Air Convection
45 º C
Output Power (%)
100
80
Safe Operating Area
60
40
35
20
75
0
- 40
- 20
0
20
40
60
80
100
Ambient Temperature º C
Control ON/OFF pin connection example
Single Output
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40U-IZ
40Watt | DC-DC Converter
Dual Output
Digital Control Circuit:
Vpeak
Control
Voltage
On / Off Control
0.5mA
NPN
0V
Ra =
Vpeak – 0.6
DC/DC
Converter
-V input
0.5mA
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only