FERYSTER E32/6/20-3C90-A315-E Planar e cores and accessory Datasheet

FERROXCUBE
DATA
A SH
SHEET
EET
E32/6/20
Planar E cores and accessories
Supersedes data of February 2002
2004 Sep 01
Ferroxcube
Planar E cores and accessories
E32/6/20
CORES
Effective core parameters of a set of E cores
SYMBOL
PARAMETER
VALUE
handbook, halfpage
UNIT
Σ(I/A)
core factor (C1)
0.323
mm−1
Ve
effective volume
5380
mm3
Ie
effective length
41.4
mm
Ae
effective area
130
mm2
Amin
minimum area
130
mm2
m
mass of core half
≈ 13
g
31.75 ±0.64
24.9 min.
6.35
±0.13
3.18 ±0.2 6.35
±0.13
R0.25 typ.
20.32 ±0.41
CBW407
R0.64 ref. typ.
Dimensions in mm.
Fig.1 E32/6/20.
Effective core parameters of an E/PLT combination
SYMBOL
PARAMETER
VALUE
UNIT
Σ(I/A)
core factor (C1)
0.278
mm−1
Ve
effective volume
4560
mm3
Ie
effective length
35.1
mm
Ae
effective area
130
mm2
Amin
minimum area
130
mm2
m
mass of plate
≈ 10
g
handbook, halfpage
31.75 ±0.64
3.18 ±0.13
Ordering information for plates
GRADE
20.32 ±0.41
TYPE NUMBER
3C90
PLT32/20/3-3C90
3C92
PLT32/20/3-3C92
3C93
PLT32/20/3-3C93
3C94
PLT32/20/3-3C94
3C96
PLT32/20/3-3C96
3F3
PLT32/20/3-3F3
3F4
PLT32/20/3-3F4
CBW408
R0.64 ref. typ.
Dimensions in mm.
Fig.2 PLT32/20/3.
2004 Sep 01
2
Ferroxcube
Planar E cores and accessories
E32/6/20
Core halves for use in combination with an E core
AL measured in combination with a non-gapped core half, clamping force for AL measurements, 30 ±10 N,
unless stated otherwise.
GRADE
3C90
AL
(nH)
AIR GAP
(µm)
µe
TYPE NUMBER
160 ±3%(1)
≈ 41
≈ 1200
E32/6/20-3C90-E160-E
±3%(1)
≈ 64
≈ 700
E32/6/20-3C90-E250-E
315 ±3%
≈ 81
≈ 550
E32/6/20-3C90-A315-E
400 ±5%
≈ 103
≈ 450
E32/6/20-3C90-A400-E
E32/6/20-3C90-A630-E
250
≈ 162
≈ 260
6425 ±25%
630 ±8%
≈ 1650
≈0
E32/6/20-3C90
3C92
5000 ±25%
≈ 1290
≈0
E32/6/20-3C92
3C93
5900 ±25%
E32/6/20-3C93
3C94
3C96
3F3
≈ 1520
≈0
±3%(1)
≈ 41
≈ 1200
E32/6/20-3C94-E160-E
250 ±3%(1)
≈ 64
≈ 700
E32/6/20-3C94-E250-E
315 ±3%
≈ 81
≈ 550
E32/6/20-3C94-A315-E
400 ±5%
≈ 103
≈ 450
E32/6/20-3C94-A400-E
630 ±8%
≈ 162
≈ 260
E32/6/20-3C94-A630-E
6425 ±25%
≈ 1650
≈0
6425 ±25%
160
≈ 1650
≈0
160 ±3%(1)
≈ 41
≈ 1200
E32/6/20-3F3-E160-E
250 ±3%(1)
≈ 64
≈ 700
E32/6/20-3F3-E250-E
315 ±3%
≈ 81
≈ 550
E32/6/20-3F3-A315-E
400 ±5%
≈ 103
≈ 450
E32/6/20-3F3-A400-E
630 ±8%
≈ 162
≈ 260
E32/6/20-3F3-A630-E
5900 ±25%
3F4
E32/6/20-3C94
E32/6/20-3C96
≈ 1520
≈0
160 ±3%(1)
≈ 41
≈ 1200
E32/6/20-3F4-E160-E
250 ±3%(1)
≈ 64
≈ 700
E32/6/20-3F4-E250-E
315 ±3%
≈ 81
≈ 550
E32/6/20-3F4-A315-E
400 ±5%
≈ 103
≈ 450
E32/6/20-3F4-A400-E
630 ±8%
≈ 162
≈ 260
E32/6/20-3F4-A630-E
3200 ±25%
≈ 820
≈0
E32/6/20-3F3
E32/6/20-3F4
Note
1. Measured in combination with an equal gapped E core half, clamping force for AL measurements, 30 ±10 N.
2004 Sep 01
3
Ferroxcube
Planar E cores and accessories
E32/6/20
Core halves for use in combination with a plate (PLT)
AL measured in combination with a plate (PLT), clamping force for AL measurements, 30 ±10 N.
GRADE
3C90
AIR GAP
(µm)
AL
(nH)
µe
160 ±3%
≈ 35
≈ 1200
E32/6/20-3C90-A160-P
250 ±3%
≈ 55
≈ 700
E32/6/20-3C90-A250-P
315 ±3%
≈ 69
≈ 550
E32/6/20-3C90-A315-P
400 ±5%
≈ 87
≈ 450
E32/6/20-3C90-A400-P
630 ±8%
≈ 138
≈ 260
E32/6/20-3C90-A630-P
TYPE NUMBER
7350 ±25%
≈ 1610
≈0
E32/6/20-3C90
3C92
5760 ±25%
≈ 1270
≈0
E32/6/20-3C92
3C93
6780 ±25%
≈ 1500
≈0
E32/6/20-3C93
3C94
160 ±3%
≈ 35
≈ 1200
E32/6/20-3C94-A160-P
250 ±3%
≈ 55
≈ 700
E32/6/20-3C94-A250-P
315 ±3%
≈ 69
≈ 550
E32/6/20-3C94-A315-P
400 ±5%
≈ 87
≈ 450
E32/6/20-3C94-A400-P
E32/6/20-3C94-A630-P
630 ±8%
3C96
3F3
≈ 138
≈ 260
7350 ±25%
≈ 1610
≈0
E32/6/20-3C94
7350 ±25%
≈ 1610
≈0
E32/6/20-3C96
160 ±3%
≈ 35
≈ 1200
E32/6/20-3F3-A160-P
250 ±3%
≈ 55
≈ 700
E32/6/20-3F3-A250-P
315 ±3%
≈ 69
≈ 550
E32/6/20-3F3-A315-P
400 ±5%
≈ 87
≈ 450
E32/6/20-3F3-A400-P
630 ±8%
≈ 138
≈ 260
E32/6/20-3F3-A630-P
≈ 1490
≈0
6780 ±25%
3F4
2004 Sep 01
E32/6/20-3F3
160 ±3%
≈ 35
≈ 1200
E32/6/20-3F4-A160-P
250 ±3%
≈ 55
≈ 700
E32/6/20-3F4-A250-P
315 ±3%
≈ 69
≈ 550
E32/6/20-3F4-A315-P
400 ±5%
≈ 87
≈ 450
E32/6/20-3F4-A400-P
630 ±8%
≈ 138
≈ 260
E32/6/20-3F4-A630-P
3700 ±25%
≈ 810
≈0
4
E32/6/20-3F4
Ferroxcube
Planar E cores and accessories
E32/6/20
Properties of core sets under power conditions
B (mT) at
CORE LOSS (W) at
H = 250 A/m;
f = 10 kHz;
T = 100 °C
f = 100 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 400 kHz;
ˆ = 50 mT;
B
T = 100 °C
E+E32-3C90
≥320
≤ 0.65
−
−
E+PLT32-3C90
≥320
≤ 0.55
−
−
E+E32-3C92
≥370
≤ 0.48
≤ 3.4
−
E+PLT32-3C92
≥370
≤ 0.41
≤ 2.9
−
E+E32-3C93
≥320
≤ 0.48(1)
≤ 3.4(1)
−
E+PLT32-3C93
≥320
≤
≤
−
E+E32-3C94
≥320
≤ 0.48
≤ 3.4
−
E+PLT32-3C94
≥320
≤ 0.41
≤ 2.9
−
E+E32-3C96
≥320
≤ 0.36
≤ 2.6
≤ 0.9
E+PLT32-3C96
≥320
≤ 0.3
≤ 2.2
≤ 0.8
E+E32-3F3
≥300
≤ 0.65
−
≤ 1.0
E+PLT32-3F3
≥300
≤ 0.6
−
≤ 0.85
E+E32-3F4
≥250
−
−
−
E+PLT32-3F4
≥250
−
−
−
GRADE
1.
0.41(1)
2.9(1)
Measured at 140 °C.
Properties of core sets under power conditions (continued)
B (mT) at
CORE LOSS (W) at
H = 250 A/m;
f = 10 kHz;
T = 100 °C
f = 500 kHz;
ˆ = 50 mT;
B
T = 100 °C
f = 500 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 1 MHz;
ˆ = 30 mT;
B
T = 100 °C
f = 3 MHz;
ˆ = 10 mT;
B
T = 100 °C
E+E32-3C90
≥320
−
−
−
−
E+PLT32-3C90
≥320
−
−
−
−
E+E32-3C92
≥370
−
−
−
−
E+PLT32-3C92
≥370
−
−
−
−
E+E32-3C93
≥320
−
−
−
−
E+PLT32-3C93
≥320
−
−
−
−
E+E32-3C94
≥320
−
−
−
−
E+PLT32-3C94
≥320
−
−
−
−
E+E32-3C96
≥320
≤ 2.0
−
−
−
GRADE
E+PLT32-3C96
≥320
≤ 1.7
−
−
−
E+E32-3F3
≥300
−
−
−
−
E+PLT32-3F3
≥300
−
−
−
−
E+E32-3F4
≥250
−
−
≤ 1.6
≤ 2.5
E+PLT32-3F4
≥250
−
−
≤ 1.36
≤ 2.2
2004 Sep 01
5
Ferroxcube
Planar E cores and accessories
E32/6/20
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2004 Sep 01
6