Rosenberger LU5-104-500 Cable assembly - standardportfolio Datasheet

Technical Data Sheet
Cable assembly - Standardportfolio
LU5-104-XXX
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
RPC-1.85 Plug / Jack – RTK 092-70 Cable – T1 Armour
All dimensions are in mm; tolerances: ± 3mm for A ≤ 300 mm; ± 1% for A > 300 mm
Available variants
Type
LU5-104-XXX
≤ 0.00639 dB/mm * A mm + 1 dB
Marking
ROSENBERGER YYYY-WW
LU5-104-XXX
FAC-RRRRRRR
ssss
Weight (g) / pce
0.1641 g/mm * A mm + 29.4 g
XXX – length in mm = A
WW – week
Note:
YYYY – year
ssss – serial no.
FAC – Factory Code
RRRRRRR – lot nr.
max. Insertion Loss:
First constant = Cable attenuation in dB /mm; Second Constant = Connector left and Connector right +needed Adaptor
Weight:
First constant = Cable and armour weight per mm; Second Constant = Connector left and Connector right weight per pce
Assembly parts
Connector left
Connector right
Cable
Armour
Electrical data
Impedance
Frequency
1
Return loss
1
Insertion loss
RPC-1.85 Plug
08S128-2U5S3
RPC-1.85 Jack
08K128-2U5S3
RTK 092-70
T1 armour Outer Diameter 9.3mm
(Polyurethane jacket over braid / stainless steel spiral)
50 Ω
DC to 70 GHz
≥ 14 dB, DC to 70 GHz
see table available variants
Individual testing and documentation:
Measurement plot with all 4 S-Parameters (S11; S22; S21; S12) is included with the cable assembly and on the
backside the care and handling instruction is printed. Measurement adaptors used are mentioned in the
commentary field.
1
RF_35/05.10/6.0
max. Insertion loss at 70 GHz
Including measurement adaptor if necessary
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : [email protected]
Page
1/2
Technical Data Sheet
Cable assembly - Standardportfolio
LU5-104-XXX
RF_35/05.10/6.0
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
RPC-1.85 Plug / Jack – RTK 092-70 Cable – T1 Armour
Mechanical data
Minimum bend radius:
Single
Multiple
12.7 mm
38.1 mm
Environmental data
Temperature range
RoHS
-40°C to +80°C
compliant
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Date
Approved
Date
Rev.
Engineering change number
Name
Date
Martin Moder
13.02.12
Florian Reiner
13.06.16
e00
16-0912
A. Youmsi Mouafo
13.06.16
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : [email protected]
Page
2/2