Intronics AC200-240 200 watt single output u frame ac-dc modules with pfc Datasheet

AC 200 Series New Product
200 Watt Single Output U Frame
AC-DC Modules with PFC
BAUART
..
GEPRUFT
..
TYPE
APPROVED
FEATURES
SPECIFICATIONS
„ 1.5” Low Profile, 4”X6” Footprint
„ Universal Input : 90 ~ 264Vac
„ Active PFC Meets EN61000-3-2
„ EMI Meets CISPR/FCC Class B
„ High Efficiency at 80% Typical
„ Current Share
„ Remote Voltage Sense
„ AC OK Signal (Logic High)
„ DC OK Signal (Logic High)
„ PS ON/OFF Remote Control
(Inhibit PSU by adding Logic High)
NOTE
1: Optional function can be added when ordering:
Top Cover with Fan (when forced air is needed)
2: Add a 0.1uF ceramic capacitor and a 47uF E.L.
capacitor to output for Ripple & Noise measuring
@20MHz BW.
3: Voltage accuracy is set at 60% rated load and 25℃ Ta.
4: Line regulation is measured from High Line to Low
Line with rated load.
5: Load regulation is measured at 60%±40% rated load.
6: Dimensions tolerance : +/- 1mm.
7: Connectors:
CN1(AC Input) : Molex 5273-05A or equivalent
CN2(DC Output) : Molex 38700-7504 or equivalent
CN6(Signals)
: Molex 70247-10 or equivalent
CN3,CN4,CN5(FAN) : Molex 5045-02A or equivalent
„ Input Characteristics
AC Input Voltage
Frequency
Inrush Current
EMI
Isolation
Leakage Current
„ Output Characteristics
Total Rated Output Power
Current Share
Remote Voltage Sense
Hold-up Time
Over Voltage Protection
Over Temperature Protection
Short Circuit Protection
„ Environmental Characteristics
Operating Temperature
Output
Storage Temperature
„ Mechanical Outline
90 ~ 264Vac
47 to 63Hz
60A Max.
CISPR/FCC Class B
Input to output = 4,242Vdc
3.5mA max.
200W (with 30CFM air flow or optional fan)
Single wire current sharing
Compensates for wire voltage drop
16mS typ.
Recycle AC input to restart
Auto Recovery
Auto Recovery
0 ~ 70 degrees C
50~70 C with 2.5%/ degrees C derating
PSU will be in thermal protection for
exceeding the rated power output or
the operating temperature
-20 ~ 85 C
Standard U Frame
150mmx100mmx38.1mm
( 5.91”*3.94”*1.5”)
With Optional Fan
150mmx101.6mmx58.5mm
( 5.91”*4”*2.3”)
Output Current (A)
Ripple
Voltage
Line
Load
Model
Voltage
Rated
Min.
& Noise
Accuracy
Reg.
Reg.
AC200-033
+3.3V
40.0
0
1%
±1%
±1%
±1%
AC200-050
+5.0V
40.0
0
1%
±1%
±1%
±1%
AC200-120
+12V
16.7
0
1%
±1%
±1%
±1%
AC200-150
+15V
13.4
0
1%
±1%
±1%
±1%
AC200-180
+18V
11.2
0
1%
±1%
±1%
±1%
AC200-240
+24V
8.4
0
1%
±1%
±1%
±1%
AC200-280
+28V
7.2
0
1%
±1%
±1%
±1%
AC200-300
+30V
6.7
0
1%
±1%
±1%
±1%
AC200-360
+36V
5.6
0
1%
±1%
±1%
±1%
AC200-480
+48V
4.2
0
1%
±1%
±1%
±1%
Typical @25℃, 230Vac and 60% rated load, unless otherwise specified.
AC 200 Series New Product
200 Watt Single Output U Frame
AC-DC Modules with PFC
DRAWINGS: (Preliminary)
CN1
Fig.1. Mechanical Outline of AC200
Unit: inch (mm)
Fig.2. Mechanical Outline of AC200-F (With Optiona1 Fan)
Unit: inch (mm)
PIN CONNECTION:
CN6(Signals)
CN1 (AC Input)
PIN NO.
ASSIGNMENT
1
Earth Ground
2
PIN10: NC
PIN9: NC
PIN8: NC
PIN7: +V CSW
PIN6: +V GS
PIN5: +V VS
PIN4: PS ON/OFF
PIN3: AC OK
PIN2: DC OK
PIN1: GND
NC
3
Neutral
4
NC
5
Line
Note: VS means Remote Sense ”+”
GS means Remote Sense “Return”
(DC Output, T.B.)
PIN NO.
ASSIGNMENT
1
+V
2
+V
3
PWR GND
4
PWR GND
CN3,CN4,CN5 (FAN Output)
PIN NO.
ASSIGNMENT
1
+12V(FAN)
2
GND(FAN)
Rated Load (W
CN2
200
175
150
125
100
75
50
25
0
With 30CFM Forced Air
Convection Cool
0
10
20
30
40
50
60
70
80
Ambient Temperature (Deg.C)
Fig.3. Output Derating Curve
2006/11/06