BLP55 AC-DC Series Data Sheet 55 Watts Features • RoHS lead-free solder and lead-solder-exempted products are available • Industry-standard 3” x 5” footprint • Main output remote sense • CE marked to Low Voltage Directive • Compliance to EN61000-4-2/-3/-4/-5/-6/-8 Description The BLP55 Series’ economical and compact construction provides single or three-output ac-dc power conversion to meet the requirements of networking and data communications systems, as well as commercial and industrial configurations. The BLP55 is rated for convection, as well as forced-air cooling. Full output power is available with external forced-air cooling. Other features include main-output remote sense and an internal EMI filter. Single Output Model Selection MODEL NOMINAL OUTPUT MIN-MAXIMUM OUTPUT VOLTAGE (VDC) CURRENT, CONVECTION MIN-MAXIMUM OUTPUT CURRENT 1 PEAK OUTPUT CURRENT 2 REGULATION % 3 RIPPLE & NOISE %p-p 4 5V 12V 24V 0 to 8A 0 to 3.3A 0 to 1.6A 0 to 11A 0 to 4.5A 0 to 2.3A 12A 5A 2.5A ±2 ±2 ±2 1 1 1 NOMINAL OUTPUT MIN-MAXIMUM OUTPUT CURRENT, CONVECTION MIN-MAXIMUM OUTPUT CURRENT 1 PEAK OUTPUT CURRENT 2 TOTAL VOLTAGE (VDC) REGULATION % 3 RIPPLE & NOISE %p-p 4 0.4 to 4A 0.2 to 2A 0.0 to 0.5A 0.5 to 4A 0.0 to 2A 0.0 to 0.5A 0.5 to 5A 0.2 to 2.5A 0.0 to 0.7A 0.5 to 5A 0.0 to 2.5A 0.0 to 0.7A 7A 4A 1 7A 4A 1A ±2 ±5 ±5 ±2.5 ±2.5 ±5 1 1 1 1 1 1 BLP55-1005 BLP55-1012 BLP55-1024 TOTAL Triple Output Model Selection MODEL BLP55-3000 BLP55-3300 +5V +12V -12V +3.3V +5V +12V NOTES: 1 10 CFM or 150 LFM (average measurement of six equally-distanced points through a 3.5” x 1.6” cross-sectional area) with power supply mounted on 0.25” standoffs. Recommended airflow direction is from the AC side to the DC side. Peak current duration for less than 30 Sec with a maximum duty cycle of 10%. 3 At 25 °C ambient including voltage set point tolerance, line, and load regulation. 4 Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth, and bypass capacitors of 10 μF and 0.1 μF. 2 Ordering Information: OPTIONS SUFFIXES TO ADD TO PART NUMBER RoHS lead solder exempt RoHS compliant for all 6 substances No RoHS character required. Add “G” as the last character of the part number. REV. MAR 31, 2006 Page 1 of 5 www.power-one.com BLP55 AC-DC Series Data Sheet 55 Watts Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Input Voltage - DC Input Frequency Input Current Inrush Surge Current Single-phase continuous input range. Consult factory. AC input. At 115 VAC input. Internally limited. Vin = 115 VAC, Max Power, 25 °C. Internally limited. Vin = 230VAC, Max Power, 25 °C. Internally located AC input line fuse rated at F, 250 V, 3.15 A. At Max Power, -3300 60% nominal. 85 100-250 264 VAC 47 50/60 1 18 36 63 Hz ARMS APK APK CONDITIONS/DESCRIPTION MIN Input Fuse Efficiency 70 % Output Specifications PARAMETER Output Power Output DC Adjustability: Overshoot Load Transient Turn-On Time from AC ON Turn-On Delay Hold-Up Time Remote Sense With convection cooling (-3300 25 W). With forced-air cooling (-3300 41 W). Adjustability of Vo1 (Vo2/Vo3 are not adjustable). NOM See Model Selection Table See Model Selection Table MAX UNITS 40 55 Watts -5%, +10% Vo1, Vo2, or Vo3 deviation due to a 50 to 100% load change at a rate of 1A/µs. Time required for output voltage to reach within regulation after initial application of AC input. Time required for output voltage to rise from 10% to 90%. At 40 W, 115 VAC Total compensation for cable losses on Vo1. (Remote Sense is not available for Vo2 or Vo3) 5 ±3 Of Nom % % 1.5 Sec 20 500 ms ms mV MAX UNITS 4.5 6.8 16.2 32.4 56.4 V 20 Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION Overvoltage Protection Main output. Short Circuit Protection REV. MAR 31, 2006 MIN 3.3V: 5V: 12V: 24V: 48V: 3.8 5.7 13.8 27.6 52.8 NOM Fully-protected against output short circuit. Page 2 of 5 www.power-one.com BLP55 AC-DC Series Data Sheet 55 Watts Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION Agency Approvals UL60950-1/CSA 22.2 No. 60950-1-03. EN 60950-1/IEC 60950-1. CB Approval. CE Mark for LVD. Ground Continuity Dielectric Withstand Voltage MIN NOM MAX UNITS 40 Input-to-Ground (Basic). 1500 2121 A VAC VDC Input-to-Ouput (Reinforced). The primary to secondary test is not performed on completed assemblies. 3000 4242 VAC VDC 500 B B VDC ESD Flicker Radiated Susceptibility EFT/Burst Input Transient Protection Output-to-Ground (Functional). FCC Part 15. CISPR 22 and CISPR 11. Per EN61000-4-2, level 3. Per EN61000-3-3. Per EN61000-4-3, level 3. Per EN61000-4-4, level 3. Per EN61000-4-5, class 3. RF Immunity Magnetic Fields Leakage Current Per EN61000-4-6, level 3. Per EN61000-4-8. Per EN60950. Electromagnetic Interference Conducted: Conducted: Class 3 Line-to-Line: Line-to-Ground: V/m kV 1 1 2 kV 3 1 BLP55-1XXX BLP55-3XXX At 264 VAC: AT 264 VAC: V/m A/m 0.48 0.72 mA Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION Altitude Operating. Non-Operating. 0 °C to 70 °C with linear derating to 50% above 50 °C. Unit will start up at -20 °C but will not meet all published specifications. Operating Temperature Storage Temperature Forced-Air Cooling Convection Cooling Temperature Coefficient Relative Humidity Shock Vibration MIN 0 NOM MAX UNITS 25 10k 50k 70 ASL Ft. ASL Ft. °C 85 °C 40 W -40 Forced-air cooling of 150 LFM at 10 CFM is required for full output power.1 (See Model Selection Table). When unit is mounted horizontally with free-air convection. (See Model Selection Table). 0 °C to 70 °C (after 15-minute warm-up). Non-Condensing. Operating: half-sine 11 ±3ms, 3 axis. Non-operating: half-sine 11±3ms, 3 axis. Operating: Random vibration, 5-500 Hz (10 minutes each axis). Non-operating: Random vibration, 5-500 Hz (10 minutes each axis). ±0.02 5 95 15 40 2.4 6.0 %/°C %RH G Grms Grms NOTES: 1 10 CFM or 150 LFM (average measurement of six equally-distanced points through a 3.5” x 1.6” cross-sectional area) with power supply mounted on 0.25” standoffs. Recommended airflow direction is from the AC side to the DC side. REV. MAR 31, 2006 Page 3 of 5 www.power-one.com BLP55 AC-DC Series Data Sheet 55 Watts Overall Size: 3.00" x 5.00" x 1.23" (76.2mm x 127.0mm x 31.2mm) Weight: 0.51 lb (0.23 kg) CN1 - AC CONN. Mechanical Drawing (Single-Output Models) 5.00 (127.0) Ø 0.16 (4 PL) (4.1) 4.55 (115.6) TOP VIEW CN1 INPUT CONNECTOR 3.00 (76.2) NEUTRAL PIN 2 MISSING PIN PIN 3 LINE CN2 - DC CON PIN #1 CN2 - DC OUTPUT CONNECTOR (SEE PINOUT TABLE) PIN 1 PIN 1 VOUT PIN 2 VOUT PIN 3 VOUT PIN 4 DC COM PIN 5 DC COM PIN 6 DC COM CN3 - REMOTE SENSE.CON SECONDARY GROUND PIN 1 + SENSE PIN 2 - SENSE PIN #1 2.55 (64.8) CN4 SAFETY GROUND CONNECTION POINT #2, FASTON TAB, 0.25", 0.03" THICK FASTENER CLEARANCE AREA 0.27" DIA (4 PL) (6.86) SAFETY GROUND CONNECTION POINT #1 CN3 - REMOTE SENSE CONNECTOR (APPROX. LOCATION) PIN #1 0.06 (1.5) 1.23 (31.2) 1.07 (27.2) SIDE VIEW PRINTED CIRCUIT BOARD END VIEW 0.1 (2.5) RECOMMENDED MATING CONNECTORS HOUSING CN1 CN2 CN3 MOLEX 09-50-8031 LEOCO 3940S030000 MOLEX 09-50-8061 LEOCO 3940S060000 MOLEX 22-01-3027 LEOCO 2530S020000 PIN 08-52-0113 3983TCB0000 08-52-0113 3983TCB0000 08-52-0113 2533TPB0000 NOTE: This is an outline drawing only. The detailed location of components is not shown. REV. MAR 31, 2006 Page 4 of 5 www.power-one.com BLP55 AC-DC Series Data Sheet 55 Watts Overall Size: 3.00" x 5.00" x 1.23" (76.2mm x 127.0mm x 31.2mm) Weight: 0.51 lb (0.23 kg) Mechanical Drawing CN1 - AC CONN. (Triple-Output Models) 5.00 (127.0) TOP VIEW CN1 INPUT CONNECTOR PIN #1 CN2 - DC OUTPUT CONNECTOR (SEE PINOUT TABLE) SECONDARY GROUND 3.00 (76.2) NEUTRAL PIN 2 MISSING PIN PIN 3 LINE CN2 - DC CON Ø 0.16 (4 PL) (4.1) 4.55 (115.6) PIN 1 PIN 1 V2 PIN 2 V1 PIN 3 V1 PIN 4 DC COM PIN 5 DC COM PIN 6 V3 CN3 - REMOTE SENSE.CON PIN 1 + SENSE PIN 2 - SENSE PIN #1 2.55 (64.8) CN4 SAFETY GROUND CONNECTION POINT #2, FASTON TAB, 0.25", 0.03" THICK FASTENER CLEARANCE AREA (4 PL) 0.27" DIA (6.86) SAFETY GROUND CONNECTION POINT #1 PIN #1 CN3 - REMOTE SENSE CONNECTOR (APPROX. LOCATION) 0.06 (1.5) 1.23 (31.2) 1.07 (27.2) SIDE VIEW PRINTED CIRCUIT BOARD END VIEW 0.1 (2.5) RECOMMENDED MATING CONNECTORS HOUSING CN1 CN2 CN3 MOLEX 09-50-8031 LEOCO 3940S030000 MOLEX 09-50-8061 LEOCO 3940S060000 MOLEX 22-01-3027 LEOCO 2530S020000 PIN 08-52-0113 3983TCB0000 08-52-0113 3983TCB0000 08-52-0113 2533TPB0000 NOTE: This is an outline drawing only. The detailed location of components is not shown. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. REV. MAR 31, 2006 Page 5 of 5 www.power-one.com