ER3AA~ER3JA SUPER FAST RECOVERY RECTIFIER VOLTAGE 50 to 600 Volt 3 Ampere CURRENT FEATURES 0.155(3.94) 0.130(3.30) • For surface mounted applications • High temperature metallurgically bonded-no compression contacts as found in other diode-constructed rectifiers 0.083(2.11) 0.075(1.91) • Glass passivated junction • Easy pick and place • Plastic package has Underwriters Laboratory Flammability Classification 94V-O 0.185(4.70) 0.160(4.06) 0.012(0.305) 0.006(0.152) 0.096(2.44) 0.083(2.13) • Lead free in compliance with EU RoHS 2011/65/EU directive • Green molding compound as per IEC61249 Std. . (Halogen Free) MECHANICAL DATA 0.050(1.27) 0.030(0.76) • Case : JEDEC DO-214AA molded plastic • Terminals : Solder plated, solderable per MIL-STD-750, Method 2026 0.220(5.59) 0.200(5.08) • Polarity : Color band denotes cathode end • Standard packaging : 12mm tape (EIA-481) • Weight : 0.0032 ounce, 0.092 gram MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%. PA RA ME TE R S YMB OL E R3 A A E R3 B A E R3 C A E R3 D A E R3 E A E R3 GA E R3 J A UNITS Ma xi m um Re c ur re nt P e a k Re ve rs e Vo lta g e V RRM 50 100 150 200 300 400 600 V Ma xi m um RM S Vo lta g e V RM S 35 70 105 140 210 280 420 V Ma xi m um D C B lo c k i ng Vo lt a g e V DC 50 100 150 200 300 400 600 V Ma xi m um A ve r a g e F o rwa r d C ur re nt I F (AV ) 3 A P e a k F o rwa r d S urg e C ur re nt : 8 .3 m s s i ng le ha lf s i ne -wa ve s up e r i m p o s e d o n r a te d lo a d IF S M 80 A Ma xi m um F o rwa rd Vo lta g e a t 3 A VF Ma xi m um D C Re ve rs e C urre nt a t Ra te d D C B lo c k i ng Vo lt a g e IR 1 A t rr 35 ns CJ 45 pF R J A R J C 135 20 T J , T S TG -5 5 t o + 1 5 0 Ma xi m um Re ve r s e Re c o ve r y Ti m e (No t e s 3 ) Typ i c a l J unc t i o n C a p a c i ta nc e Me a s ur e d a t 1 M Hz a nd a p p li e d V R = 4 V Typ i c a l The r ma l Re s i s ta nc e (No t e s 2 ) (No t e s 1 ) Op e r a ti ng a nd S t o ra g e Te m p e ra t ure Ra ng e 0 .9 5 1 .2 5 1 .7 V O C / W O C NOTES: 1. Mounted on a FR4 PCB, single-sided copper, with 100cm2 copper pad area 2. Mounted on a FR4 PCB, single-sided copper, mini pad. 3. Reverse Recovery Test Conditions: I F=0.5A , I R=1A Irr=0.25A May 23,2014-REV.00 PAGE . 1 3.5 3 2.5 2 1.5 1 0.5 0 0 25 50 75 100 125 150 TC, Case Temperature (°C) CJ, Junction Capacitance (pF) IF, Forward Current (A) ER3AA~ER3JA 10 1 1 TJ = 150°C 1 TJ = 125°C 0.1 TJ = 75°C 0.01 TJ = 25°C 50~200V 0.001 40 80 120 160 TJ = 150°C 1 TJ = 125°C 0.1 TJ = 75°C 0.01 TJ = 25°C 300~400V 0.001 80 200 160 240 320 400 Rated Peak Reverse Voltage (V) Rated Peak Reverse Voltage (V) Fig.4 Typical Reverse Characteristics Fig.3 Typical Reverse Characteristics 10 TJ = 150°C 10 TJ = 125°C 1 TJ = 75°C 0.1 TJ = 25°C 600V 0.01 10 20 30 40 50 60 70 80 90 100 Percent of Rated Peak Reverse Voltage (%) Fig.5 Typical Reverse Characteristics May 23,2014-REV.00 IF, Forward Current (A) 100 IR, Reverse Current (μA) 100 VR, Reverse Bias Voltage (V) 10 10 10 Fig.2 Typical Junction Capacitance IR, Reverse Current (μA) IR, Reverse Current (μA) Fig.1 Forward Current Derating Curve 100 TJ = 150°C 1 0.1 TJ = 125°C TJ = 75°C TJ = 25°C 0.01 50~200V 0.001 0 0.2 0.4 0.6 0.8 1 VF, Forward Voltage (V) Fig.6 Typical Forward Characteristics PAGE . 2 ER3AA~ER3JA 10 IF, Forward Current (A) IF, Forward Current (A) 10 TJ = 150°C 1 TJ = 75°C TJ = 125°C 0.1 TJ = 25°C 0.01 300~400V 0.001 TJ = 150°C 1 TJ = 125°C 0.1 TJ = 75°C 0.01 TJ = 25°C 600V 0.001 0 0.5 1 1.5 VF, Forward Voltage (V) Fig.7 Typical Forward Characteristics May 23,2014-REV.00 0 0.5 1 1.5 2 VF, Forward Voltage (V) Fig.8 Typical Forward Characteristics PAGE . 3 ER3AA~ER3JA MOUNTING PAD LAYOUT ORDER INFORMATION • Packing information T/R - 3K per 13" plastic Reel T/R - 0.5K per 7" plastic Reel May 23,2014-REV.00 PAGE . 4 ER3AA~ER3JA Part No_packing code_Version ER3AA_R1_00001 ER3AA_R2_00001 For example : RB500V-40_R2_00001 Serial number Version code means HF Packing size code means 13" Part No. Packing type means T/R Packing Code XX Packing type Tape and Ammunition Box (T/B) Tape and Reel (T/R) Bulk Packing (B/P) Tube Packing (T/P) Tape and Reel (Right Oriented) (TRR) Tape and Reel (Left Oriented) (TRL) FORMING May 23,2014-REV.00 Version Code XXXXX 1st Code Packing size code A N/A 0 HF 0 serial number R 7" 1 RoHS 1 serial number B 13" 2 T 26mm X S 52mm Y L F PANASERT T/B CATHODE UP (PBCU) PANASERT T/B CATHODE DOWN (PBCD) 2nd Code HF or RoHS 1st Code 2nd~5th Code U D PAGE . 5 ER3AA~ER3JA Disclaimer •Reproducing and modifying information of the document is prohibited without permission from Panjit International Inc.. •Panjit International Inc. reserves the rights to make changes of the content herein the document anytime without notification. Please refer to our website for the latest document. •Panjit International Inc. disclaims any and all liability arising out of the application or use of any product including damages incidentally and consequentially occurred. •Panjit International Inc. does not assume any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. •Applications shown on the herein document are examples of standard use and operation. Customers are responsible in comprehending the suitable use in particular applications. Panjit International Inc. makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. • The products shown herein are not designed and authorized for equipments requiring high level of reliability or relating to human life and for any applications concerning life-saving or life-sustaining, such as medical instruments, transportation equipment, aerospace machinery et cetera. Customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Panjit International Inc. for any damages resulting from such improper use or sale. •Since Panjit uses lot number as the tracking base, please provide the lot number for tracking when complaining. May 23,2014-REV.00 PAGE . 6