The ABC120 Series of open frame power supplies feature a wide
universal AC input range of 85 V – 264 VAC, offering 120 W of output
power in a compact footprint, with a variety of isolated single output
voltages.
The high efficiency and high power density of the ABC family ensures
minimal power loss in end-use equipment, thereby facilitating higher
reliability, easier thermal management and meets regulatory approvals
for environmentally-friendly end products.
ABC Series power supplies are ideal for telecom, datacom, industrial
equipment and other applications.
•
3 x 2 x 1 Inch Footprint
•
120 Watts with Forced Air Cooling
•
Efficiencies up to 93%
•
-40 to 70°C Operating Temperature
•
Thermal Shut-Down Feature
•
3.00 Million Hours, Telcordia -SR332-Issue 3
•
Standby Power < 0.3 W
•
RoHS Compliant
•
CE Marked
•
Instrumentation
•
Renewable Energy
•
Lighting
•
Test and Measurement
•
Industrial Applications
•
Robotics
•
Applied Computing
•
Wireless Communication
ABC120 Series
2
ABC120-1T12L
ABC120-1012L
Screw Terminal
Molex Header
12 V
8.33 A
10.0 A
0.0 A
1%
ABC120-1T15L
ABC120-1015L
Screw Terminal
Molex Header
15 V
6.66 A
8.0 A
0.0 A
1%
ABC120-1T24L
ABC120-1024L
Screw Terminal
Molex Header
24 V
4.16 A
5.0 A
0.0 A
1%
ABC120-1T30L
ABC120-1030L
Screw Terminal
Molex Header
30 V
3.33 A
4.0 A
0.0 A
1%
ABC120-1T48L
ABC120-1048L
Screw Terminal
Molex Header
48 V
2.08 A
2.5 A
0.0 A
1%
ABC120-1T58L
ABC120-1058L
Screw Terminal
Molex Header
58 V
1.72 A
2.07 A
0.0 A
1%
COVER-120-XBC2
metal cover kit accessory
Specifications are for nominal input voltage, 25°C unless otherwise stated.
Input Voltage
Universal (see derating under output power)
Input Frequency
85-264 VAC / 390 VDC3
47-63 Hz
Input Current
115 VAC:
230 VAC:
1.2 A max.
0.65 A max.
No Load Power
Typical
< 0.3 W
Inrush Current
115 VAC:
230 VAC:
264 VAC:
25 A
45 A
75 A
Power Factor
@ Full Load, Active PFC
> 0.95
Switching Frequency
Typical
60 kHz
1
Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Tantalum capacitor) in parallel with a 0.1 μF capacitor at rated line voltage
and load ranges.
2
When used in Cover Kit, de-rate output power to 70 % under all operating conditions
3
Functional, not approved.
[email protected]
ABC120 Series
Output Power
Efficiency
Hold-up Time
3
Forced cooling (with 300LFM):
Convection cooling
(de-rate linearly to 80 W @ 85 VAC):
48 V, 58 V:
24 V, 30 V:
12 V, 15 V:
120 W
100 W (for input 100-264 VAC)
93%
91%
90%
Typical
>10 ms
Line Regulation
+/-0.5%
Load Regulation
Transient Response
+/-1%
25% step load change, at 0.1A/uS slew rate,
50% duty cycle, 50 Hz = 4%
recovery time < 5 ms
Voltage Adjustment
Rise Time
+/-3%
Typical
55 ms
Set Point Tolerance
+/-1%
Over Current Protection
> 110%
Over Voltage Protection
Latch type (AC recycling required)
Short Circuit Protection
Hiccup mode
110 to 140%
Conducted Emissions
EN55032-B, CISPR22-B, FCC PART15-B
Pass
Radiated Emissions
EN 55032 A;
with external core (King core K5B RC 25x12x15-M in input cable)
Pass
Level B
Input Current Harmonics
EN 61000-3-2
Class D
Voltage Fluctuation and Flicker
EN 61000-3-3
Pass
ESD Immunity
EN 61000-4-2
Level 3, Criterion A
Radiated Field Immunity
EN 61000-4-3
Level 3, Criterion A
Electrical Fast Transient Immunity
EN 61000-4-4
Level 3, Criterion A
Surge Immunity
EN 61000-4-5
Level 3, Criterion A
Conducted Immunity
EN 61000-4-6
Level 3, Criterion A
Magnetic Field Immunity
EN 61000-4-8
Level 3, Criterion A
Voltage Dips, Interruptions
EN 61000-4-11
Criterion A & B
Isolation Voltage
Safety Standard(s)
Input to Output: (For ITE application)
Input to GND:
Approved to the latest edition of the following standards:
CSA/UL60950-1, EN60950-1 and IEC60950-1; Class1 SELV.
Agency Approvals
Nemko, UL, C-UL, CCC
CE mark
Complies with LVD Directive
3000 VAC
1500 VAC
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2017 Bel Power Solutions & Protection
BCD.00666_AC
Asia-Pacific
+86 755 298 85888
ABC120 Series
4
Operating Temperature4
-40 to +70°C
-40 to 0°C
Startup guaranteed (derate linearly above 50°C to 70°C, see Fig 1.)
Storage Temperature
-40 to +85°C
Cooling
Forced: with 300LFM (refer mechanical drawing)
Convection: for input 100-264 VAC (derate linearly to 80 W @ 85 VAC)
120 W
100 W
Relative Humidity
Noncondensing
5% to 95%
Altitude
Operating:
Non-operating:
16,000 ft
40,000 ft.
Reliability
MTBF according to Telcordia -SR332-Issue 3
3.00 million hours
Convection load: 100 W up to 50 °C
De-rate above 50 °C @ 2.5% per °C
Forced air cooled load: 120 W up to 50°C
De-rate above 50 °C @ 2.5% per °C
Figure 1. Derating Curve
AC Input Connector
DC Output Connector
J1
J2
Pin 1
Pin 2
Pin 3
AC Line
Not Fitted
AC Neutral
Pin 1, 2
Pin 3, 4
V1 -VE
V1 +VE
Screw Terminal (Option 1)
Molex Header (Option 2)
Screw Terminal (Option 1)
Molex Header (Option 2)
Weight
150 g
Dimensions
76.2 x 50.8 x 30.1 mm (3 x 2 x 1.18 inch)
4
Molex: 39357-0003
Tyco-2-1776112-3
Molex: 1722861103
(Mating conn: Molex 1722561003)
Molex: 39357-0004
Tyco-2-1776112-4
Molex: 1722861104
(Mating conn: Molex 1722561004)
Output ripple can be more than 10% of the output voltage.
[email protected]
ABC120 Series
5
Figure 2. Mechanical Drawing - Screw Terminal (Option 1)
Figure 3 - Mechanical Drawing - Molex Header (Option 2)
NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following:
1
Stand off, used to mount PCB has OD of 5.4 mm max.
2
Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
3
Washer, if used, to have dia of 6.5 mm max.
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2017 Bel Power Solutions & Protection
BCD.00666_AC
Asia-Pacific
+86 755 298 85888
Similar pages