ETC2 OA5669.12 Safety relay Datasheet

Safety relay
OA / OW 5669
• according to EN 50 205, IEC/EN 60 255,
IEC 60 664-1
• with positively driven contacts
• wash proof model as option
• double and reinforced insultaion between
contact sets according to EN 50 178
• low rated power consumption
• high mechanical service life
• compact size, small height
• Approvals: UL, CSA,
TÜV approval: R 9012316
Applications:
ZH1/457 press controls
Switchgear for safety technology
OA / OW 5669
Technical data
Relay type
1. 0 Relay coil
1. 1 Nominal voltage
1. 2 Nominal consumption
OA 5669
DC V
W
5, 6, 12, 20, 24, 48, 60, 110
0,7
2. 0 Contacts
2. 1 Contact arrangement
2. 2 Contact material
2. 3 Rated insulation voltage
AC V
Switching voltage min./max.
V
2. 4 Limiting continuous current
A
Switching current min./max.
A
2. 5 Switching power min./max.
VA
Switching power min./max.
W
2. 6 Switching capacity
to IEC/EN 60 947-5-1 AC 15
AC V/A
DC 13
DC V/A
2. 7 Electrical life 2)
AC 230 V 6 A cos ϕ = 1
switching cycles
2. 8 Switching frequency max. switching cycles / s
2. 9 Response time / Release time
ms
2.10 Contact force NO / NC
cN
3.
3.
3.
3.
3.
3.
3.
3.
1)
0
1
2
3
4
5
6
8
1 NC / 1NO
2 changeover contacts, 1 No and 1 changeover contact
AgCdO + 0,2 µm Au; AgNi 10 + 0,2 µm Au optionally + 5 µm Au
250
AC/DC 10 / DC 250, AC 400 (AC/DC 100 mV / 60 V) 1)
2 x 5 (see operating voltage limit curve)
10mA3) / 8 (1 mA / 0,3 A)1)
3 / 2 000 (1 mVA / 7 VA)1)
3 / 200 (1 mW / 7 W) 1) (s. limit curve for arc-free operation)
Other
Mechanical life
switching cycles
Temperature range
°C
Degree of protection, housing
Housing
Vibration resistance
Climate resistance
Insolation according to IEC 60 664-1, EN 50 178
Rated insulation voltage
AC V
Contamination level
Overvoltage category
Values for AgNi 10-contacts + 5 µm Au
2)
NC: 230 / 1
NC: 24 / 2
at 1 s On, 1 s Off
> 1 x 105 AgNi 10
10
≤ 15 / ≤ 12
≥ 10 / ≥ 8
≥ 50 x 106
- 40 ... + 60 mounted without distance (Ith = 2 x 5 A)
IP40 / IP67 IEC/EN 60 529 wash proof
Thermoplast GF, PA
10 ... 55 Hz; 0,35 mm amplitude; 5 g max. IEC/EN 60 068-2-6
40 / 060 / 04 (climate category); A/B/D IEC/EN 60 068-1
double and reinforced insulation
250
2
III
10 A total current at t = 20°C and coil voltage UN
All technical data in this list relate to the state at the moment of edition.
We reserve the right for technical improvements and changes at any time.
NO: 230 / 3
NO: 24 / 2
(s. contacts service life)
> 2 x 105 AgCdO
3)
Typical values
OA/ OW 5669 / 25.02.03 d
Technical data
3. 8 Test voltage
contact-coil (1 min)
AC kV eff.
contact-contact (1 min)
AC kV eff.
Transient volt. contact-coil (1,2 - 50 µs)
kV
Clearance and creepage distances as per IEC/EN 60 730, IEC/EN 60 335
contact-coil
mm
contact-contact:
mm
3. 9 Weight
g
Standard variants
≥4
≥4
≥6
≥8
≥ 5,5
15
Ordering example
UN
Voltage
Resistance
Design version
DC
range
at 20°C
OA / OW
V
DC V
Ω
.16
.16
.12
5
4,0...8,0
36
461
991
980
6
4,8...9,6
50
462
992
981
12
9,6...19,2
210
463
993
982
20
16,0...32,0
580
468
998
987
24
19,2...38,4
820
464
994
983
48
38,4...76,8
3 200
465
995
984
60
48,0...96,0
5 200
466
996
985
110
88,0...176
18 000
467
997
986
O
5669.16 /
Design version
Contact arrangement
.16 1 NC / 1 NO
.12 2 changeover contacts
.20 1 NO /1changeover contact
Degree of protection
A = IP 40 (solder line proof)
W = IP 67 (wash proof)
Characteristics
4
U B max.
without load
1,4
M2870
M2869
1,6
2
10 7
1,2
U B max.
at 8A load
1,0
Switching cycles
UB
UN
10 8
6
0,8
U B min.
0
20
40
60
6
4
2
AgCdO
10 6
6
4
AgNi10
80°C
2
Ambient temperature
10 5
0
0,2 0,4 0,6 0,8 1,0
1,2
1,4 1,6
Switching capacity P [ kVA ]
0,6
Reduction factor F
Contact material
AgNi
260
Switching voltage U [
M2642
1,0
0,9
0,8
0,7
0,5
0,4
0,3
M2871
Contact service life (at tu = 20°C)
V]
Operating voltage limit curve
220
180
140
100
60
0,2
0,2
0,4
0,6
0,8
Power factor (cos )
Number of cycles =
Number of cycles (ohmic) x reduction factor F
Reduction factor for inductive loads
20
0
1
0,2
0,4
0,7
2
4
Switching current I [ A ]
safe switch-off, no standing arc
arc max. 1 switching cycle / s
Limit curve for arc-free operation
(at tu = 20°C)
6 8 10
Dimensions, pin configuration, connection diagrams
Connection for basic grid divensions 2,5 mm as well as 2,54 mm according to IEC/EN 60 097 and IEC 60 326 average
Dimensions, pin configuration, connection diagrams
Connection for basic grid divensions 2,5 mm as well as 2,54 mm according to IEC/EN 60 097 and IEC 60 326 average
Accessories
34
32
M2980
Fixing clip
Function modul
4
10
Relay
socket
1 x 0,5
2x5
20,1
max. 31,5
7,5
max. 13
Socket
ET 1415.021 ANR 0034 769
Fixing clip ET 1415.025 ANR 0034 770 Wire
Fixing clip ET 1415.026 ANR 0047 726 Plastic
Relay socket ET 1415.041 ANR 0055571
with fixing clip WN 1415.902.790
Function modul ET 1415.911 ANR 0055909
- DC, with free-wheeling diode and red LED
Function modul ET 1415.912 ANR 0055910
- AC/DC with green LED
E. DOLD & SÖHNE KG • D-78114 Furtwangen
Postf. 1251 • Tel. (07723) 6540 • Fax (07723) 654356 • e-mail [email protected] • internet http: //www.dold.com