Power-One ABC300 200 w convection cooled, inhibit and power good signal Datasheet

DATA SHEET
ABC300 SERIES 300W AC/DC
FEATURES

200 W convection cooled

-20 to 50 deg C full load operation

3” x 5“ x 1.5” (76.2 x 127 x 38.1 mm)

No minimum load required

12 V fan & 5 V standby outputs

Inhibit and Power Good signals

Conducted EMI EN 55022-B, FCC Part 15 Level B

ITE Safety Agency Approvals

RoHS Compliant
APPLICATIONS

Instrumentation

Renewable Energy

Lighting

Data Comm.

Industrial Applications

Applied Computing

Test and Measurement

Process Control

Robotics

Wireless
BCD.00285_AA_September-18-2013
1
www.power-one.com
DATA SHEET
TECHNICAL DATA:
Input
PARAMETER
DESCRIPTION/CONDITION
Input voltage range
Universal Input
Input frequency range
47-63 Hz
Input surge current
230 Vac (cold start)
65 A max.
Safety ground leakage current
230 Vac
120 Vac @ 200 W
230 Vac @ 200 W
300 μA max
3.2 A
1.65 A
Input current
90 - 264 Vac
120 – 390 Vdc
Output
PARAMETER
DESCRIPTION/CONDITION
Voltage Adjustment
V1
± 3%
Transient Response
Main output 50 to 100% load change, 50 Hz,
50% duty cycle, 0.1 A / uSec, 50/60 Hz.
< 10%, recovery time < 5 mSec
Over Voltage Protection
V1
110 to 150% rated max
Over Current Protection
Rated output current
110 to 150% Typical
Short Circuit Protection
Automatic recovery
Over Temperature Protection
Automatic recovery
Set point tolerance
± 1%
Rise Time
<100 mSec
110° C primary heatsink
Ordering Information
PRODUCT FAMILY
VOLTS
MAX LOAD
MAX LOAD
(VDC) CONVECTION (2) 300 LFM (2)
MINIMUM
LOAD (A)
RIPPLE &
NOISE (4)
CONNECTOR
TOTAL
REGULATION
ABC300-1T05G
5
28.0 A
40.0 A
0
2%
Screw Terminal
± 2.5%
ABC300-1T12G
12
15.0 A
25.0 A
0
2%
Screw Terminal
± 2.5%
ABC300-1T15G
15
12.0 A
20.0 A
0
2%
Screw Terminal
± 2.5%
ABC300-1T24G
24
7.5 A
13.54 A
0
2%
Screw Terminal
± 2.5%
ABC300-1T30G
30
6.0
10.83 A
0
2%
Screw Terminal
± 2.5%
ABC300-1T48G
48
3.75 A
6.77 A
0
2%
Screw Terminal
± 2.5%
Vfan (all models)
12
0.5 A
0.5 A
0
± 20%
V s/b (all models)
5
2.0 A
2.0 A
0
± 5%
Notes:
1.
2.
3.
4.
5.
Peak current rating of 120% of max, < 30 Sec with max of 10% duty cycle.
Combined power from main output, Vfan and Vs/b should not exceed total power rating.
Fan output tolerance is ± 20%. When V1 full load, Vfan needs 20 mA load to be within regulation specification. Peak
current for fan output is 1 A.
Ripple is 2% up to 20% load and less than 1% above 20% load. Output noise measurement is made with a 20 MHz
bandwidth using a 6” twisted pair, terminated with a 10 uF tantalum capacitor in parallel with a 0.1 uF ceramic capacitor.
Specifications are for nominal input voltage, 25° C and max load unless otherwise stated.
ABC300 Series
2
www.power-one.com
DATA SHEET
6.
7.
8.
9.
10.
11.
Class 1 models have Earthing tab J4. Class 2 models (-2 suffix) have no Earthing tab.
Derate power linearly to 80% from 90 Vac to 80 Vac input.
Power supply shipped with J3 pin 1 and 2 shorted to enable main output
Specifications subject to change without notice.
Air flow over long edge (either direction) required for air flow rating. See mechanical drawing below.
Warranty 2 years.
General Specifications
PARAMETER
DESCRIPTION/CONDITION
MTBF
120 Vac
230 Vac
>250 khrs
Switching Frequency
PFC converter 80 kHz typical
Isolation Voltage
Weight
Min 5900 Vdc
450 g (0.99 lbs)
Hold Up Time
10 mSec
10 mSec
Bellcore TR-332
Resonant converter: Variable 35 to 250
kHz, 90 kHz typical
Input to Output
Environmental
PARAMETER
DESCRIPTION/CONDITION
Operating
-20 to 70° C. See derating charts below.
Storage
-40 to +85° C.
Altitude
Operating 10,000 ft.
Non-operation 40,000 ft.
Conducted emissions:
EN55022, FCC part 15 Level B
Radiated Emissions
EN55022, FCC part 15 Level B
To be controlled in end system
Electromagnetic Susceptibility
EN61000-4 3
2, 3, 4, 5 level 3
Harmonic Current
EN61000-3-2, Class D
Operating Temperature
Signals
PARAMETER
DESCRIPTION/CONDITION
Power Good
TTL signal goes high after main output is within regulation, delay is 0.1 to 0.3 sec
Inhibit
To turn on power supply short J3 pin 1 to J3 pin 2 or J3 pin 7
Remote Sense
Compensates for 200 mV drop
Safety
PARAMETER
DESCRIPTION/CONDITION
EN / UL / CSA
EN60950-1+A12:2011, IEC60950-1 2nd+A1 2009, CSA-22.2 No 60950-01-07+ A1, UL609501-2011
BCD.00285_AA_September-18-2013
3
www.power-one.com
DATA SHEET
Figure 1 Output Power Vs. Temperature
Figure 2 Dimension Drawing (Top and Side View)
ABC300 Series
4
www.power-one.com
DATA SHEET
Mechanical
INPUT = J1
EARTHING TAB = J4
DC OUTPUT = J2
SIGNALS & AUX POWER= J3
Pin 1: AC Line
Pin 2: AC Neutral
Molex: 19705-4301
2 x 6-32 inches pan head screw
Pin 1 = RTN
Pin 2 = V1
Pin 1 = Inhibit
Pin 2 = Signal Return
Pin 3 = Vfan (+12 V)
Pin 4 = - Remote Sense
Pin 5 = Vs/b (5 Vdc)
Pin 6 = + Remote Sense
Pin 7 = Signal Return
Pin 8 = Power Good
Mating Connector:
Molex: 09-50-3031
Pins: 08-50-0106
Mating Connector:
Molex: 190030001
Mating Connector:
16 AWG wire crimped to Ring
Tongue Terminal.
AMP: 8-31886-1
Mating Connector:
Molex: 22-01-2087, Pins: 08-50-0113
Copyright © 2010 Power-One Inc. All rights reserved. Words and logos that are identified as trademarks and/or service marks are, unless noted otherwise, the
trademarks and service marks of Power-One Inc. in the U.S. and other countries. All other product or service names are the property of their respective holders.
Power-One products are protected under numerous U.S. and foreign patents and pending applications, maskwork rights, and copyrights. Power-One reserves the
right to make changes to any products and services at any time without notice. Power-One assumes no responsibility or liability arising out of the application or use
of any information, product, or service described herein except as expressly agreed to in writing by Power-One Inc.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of
Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
BCD.00285_AA_September-18-2013
5
www.power-one.com
Similar pages