HRP-300 300W Single Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 High efficiency up to 89% (typ.) Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage / Over temperature Built-in constant current limiting circuit 1U low profile 41mm Built-in cooling fan ON-OFF control With DC OK signal output Built-in remote sense function 5 years warranty SPECIFICATION MODEL OUTPUT HRP-300-3.3 HRP-300-5 HRP-300-7.5 HRP-300-12 HRP-300-15 HRP-300-24 HRP-300-36 HRP-300-48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V 48V RATED CURRENT 60A 60A 40A 27A 22A 14A 9A 7A CURRENT RANGE 0 ~ 60A 0 ~ 60A 0 ~ 40A 0 ~ 27A 0 ~ 22A 0 ~ 14A 0 ~ 9A 0 ~ 7A RATED POWER 198W 300W 300W 324W 330W 336W 324W 336W RIPPLE & NOISE (max.) Note.2 80mVp-p 90mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 250mVp-p 250mVp-p VOLTAGE ADJ. RANGE 4.3 ~ 5.8V 2.0% 6.8 ~ 9V 2.0% 10.2 ~ 13.8V 1.0% 13.5 ~ 18V 1.0% 21.6 ~ 28.8V 1.0% 28.8 ~ 39.6V 1.0% 40.8 ~ 55.2V 1.0% 2.8 ~ 3.8V VOLTAGE TOLERANCE Note.3 2.5% LINE REGULATION 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% LOAD REGULATION 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1000ms, 50ms/230VAC HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE Note.5 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz INPUT PF>0.95/230VAC EFFICIENCY (Typ.) 80% 82% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 5A/115VAC 35A/115VAC 2.5A/230VAC 70A/230VAC LEAKAGE CURRENT <1.2mA / 240VAC OVER VOLTAGE PF>0.99/115VAC at full load 86% 88% 88% 87% 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 3.96 ~ 4.62V 88% 89% 41.4 ~ 48.6V 57.6 ~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover 90 FUNCTION 120 ~ 370VDC POWER FACTOR (Typ.) OVERLOAD PROTECTION 2500ms, 50ms/115VAC at full load OVER TEMPERATURE 100 (TSW1: detect on heatsink of power transistor) 5 5 for 3.3V,5V,7.5V ; 95 5 for others (TSW2: detect on heatsink of power diod e) DC OK SIGNAL Protection type : Shut down o/p voltage, recovers automatically after temperature goes down PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V FAN CONTROL (Typ.) Load 35 15% or RTH2 WORKING TEMP. -30 ~ +70 50 Fan on (Refer to output load derating curve) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note 4) ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT OTHERS / 70% RH EMS IMMUNITY Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, heavy industry level, criteria A MTBF 176K hrs min. DIMENSION 199*105*41mm (L*W*H) 0.95Kg;15pcs/15.3Kg/0.69CUFT PACKING NOTE UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:HRP-300-SPEC 2009-11-09 HRP-300 300W Single Output with PFC Function Mechanical Specification Unit:mm 18 12.5 Case No.980A series 4-M4 L=6 12.25 168.5 168.5 R2 199 12.25 .25 168.5 120 42.5 18 1.5 HOLE IN CHASSIS 4.5 1 4-M4 L=5 11 2 3 6 7 LED CN100 SVR Connector Pin No. Assignment (CN100) : HRS DF11-08DP-2DS or equivalent Pin No. Assignment 1,2,4,6 NC DC-OK 3 5 GND +S 7 -S 8 Terminal Mating Housing 167.5 12.25 167.5 12.25 17max. 12.5 18 41 HRS DF11-**SC or equivalent HRS DF11-8DS or equivalent 4-M4 L=6 fosc : 70KHz Block Diagram +S ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P Air flow direction 15 1 7 Assignment Pin No. DC OUTPUT -V 4,5 6,7 DC OUTPUT +V 2 8 Assignment AC/L AC/N FG Pin No. 1 2 3 FAN 5 75 105 125 9.2 4 Terminal Pin No. Assignment RECTIFIERS & PFC POWER SWITCHING O.T.P. O.L.P. PFC CONTROL PWM CONTROL RECTIFIERS & FILTER +V -V -S FG Derating Curve DC OK DETECTION CIRCUIT O.V.P. Output Derating VS Input Voltage Ta = 25 100 100 90 80 80 70 50 LOAD(%) LOAD (%) 60 40 20 -30 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 85 100 125 135 155 264 INPUT VOLTAGE (V) 60Hz File Name:HRP-300-SPEC 2009-11-09