Online data sheet OLM200-1052 OLM200 LINEAR MEASUREMENT SENSORS OLM200-1052 | OLM200 LINEAR MEASUREMENT SENSORS A B C D E F Ordering information Type Part no. OLM200-1052 1051659 Other models and accessories www.sick.com/OLM200 Detailed technical data Performance H I J K L M N O P Q R S T Resolution 0.1 mm, 1 mm, 10 mm, 100 mm Repeatability 0.15 mm 1) Response time 10 ms 2) Output time 2.5 ms Light source LED, red Measurement range 0 m ... 10,000 m 3) Accuracy of speed output ± 5 mm/s Max. movement speed 10 m/s Sensing distance 130 mm, ± 20 mm Bar code width 40 mm 1) 2) 3) Statistical error 3 s, no warm-up time required. Response time of switching output. Dependent on the set resolution and transfer protocol. Interfaces Data transmission rate 3 Mbit/s Maximum baudrate 12 MBaud Switching output MF1: PNP, MF1: NPN 1) Data interface PROFIBUS DP-V0 1) Functions of switching output MF1 PNP/MF1 NPN: position, speed, control mark Q00 (off), Q01 (on), illumination on/off, service [prefailure (dirt/LED life time), no bar code tape, over/under temperature, out of range 0 km > position > 10 km, internal error]. Mechanics/electronics Supply voltage Vs DC 18 V ... 30 V 1) Ripple ≤ 5 Vpp 2) 1) 2) 3) 2 Limit values, reverse-polarity protected. May not exceed or fall below Uv tolerances. Switching outputs MF1 short-circuit protected. DISTANCE SENSORS | SICK Online data sheet | 2016-05-02 22:08:07 Subject to change without notice OLM200-1052 | OLM200 LINEAR MEASUREMENT SENSORS Power consumption < 5.5 W Initialization time 3s Housing material Magnesium Zinc Weight Approx. 291 g Output current IA 100 mA 3) 1) 2) 3) Limit values, reverse-polarity protected. May not exceed or fall below Uv tolerances. Switching outputs MF1 short-circuit protected. Ambient data Enclosure rating IP 65 (EN 60 529) Protection class III Electromagnetic compatibility (EMC) EN 61000-6-2 EN 61000-6-4 Ambient temperature Operation: –30 °C ... +60 °C 1) Storage: –40 °C ... +75 °C 2) Typ. Ambient light immunity ≤ 30,000 lx 3) Vibration resistance DIN/EN 60068-2-6, DIN/EN 60068-2-64 Shock resistance DIN/EN 60068-2-27 1) 2) 3) Temperatures < –20 °C with 5 min warm up time. Max. 95 % humidity, non-condensing. Typ. value at +25 °C ambient temperature. 2016-05-02 22:08:07 | Online data sheet Subject to change without notice DISTANCE SENSORS | SICK 3 OLM200-1052 | OLM200 LINEAR MEASUREMENT SENSORS OLM200, PROFIBUS 64.6 (2.54) 1 5 .5 2) 2 8 63.4 (2.50) 8 8 3 5 4 6 7 22.2 22.2 22.2 (0.87) (0.87) (0.87) 106.9 (4.21) 31.9 (1.26) 0.2 51.8 (2.04) Ø (Ø 24 (0.94) 89.8 (3.54) 74.4 (2.93) 9 9 3 42 (1.65) 2 (0.08) 22 (0.87) 13.8 (0.54) 3.3 (0.13) H I J K L M N O P Q R S T Dimensional drawing (Dimensions in mm (inch)) 5.5 (0.22) A B C D E F 51.5 (2.03) ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ 4 Reference axis position measurement Fixing hole Status LED [status] Ethernet connection M12, 4-pin Fieldbus connection M12, 5-pin (e. g., PROFIBUS out) Fieldbus connection M12, 5-pin (e.g. PROFIBUS in) Connector M12, 5-pin Adjustment aid (slot) T-slot DISTANCE SENSORS | SICK Online data sheet | 2016-05-02 22:08:07 Subject to change without notice OLM200-1052 | OLM200 LINEAR MEASUREMENT SENSORS Connection type Socket 1 x M12, 4-pin 1 x M12, 5-pin connector 1 x M12, 5-pin 4 1 3 2 2 3 5 1 2 1 5 3 4 4 1 4 ① ② ③ ④ 3 3 4 2 2 1 Ethernet connection M12, 4-pin Fieldbus connection M12, 5-pin (e. g., PROFIBUS out) Fieldbus connection M12, 5-pin (e.g. PROFIBUS in) Connector M12, 5-pin Connection diagram 5 5 5 ① ② ③ ④ ⑤ 5 Ethernet connection M12, 4-pin Fieldbus connection M12, 5-pin (e. g., PROFIBUS out) Fieldbus connection M12, 5-pin (e.g. PROFIBUS in) Connector M12, 5-pin Not assigned Recommended accessories Other models and accessories www.sick.com/OLM200 Brief description Type Part no. Sliding nuts 2017550 Head A: female connector, M12, 5-pin, straight Head B: cable Cable: PROFIBUS DP, PUR, halogen-free, shielded, 5 m DOL-1205-G05MQ 6026006 Head A: female connector, M12, 5-pin, angled, B-coded Head B: cable Cable: PROFIBUS DP, drag chain use, PUR, shielded, 5 m DOL-1205-W05MQ 6041423 Head A: male connector, M12, 5-pin, angled, B-coded Head B: cable Cable: PROFIBUS DP, drag chain use, PUR, shielded, 5 m STL-1205-W05MQ 6041426 Other mounting accessories 4 pieces, Sliding nut set, M5, 4x, Included in delivery Plug connectors and cables 2016-05-02 22:08:07 | Online data sheet Subject to change without notice DISTANCE SENSORS | SICK 5 OLM200-1052 | OLM200 LINEAR MEASUREMENT SENSORS A B C D E F H I J K L M N O P Q R S T Brief description 6 Type Part no. Head A: male connector, M12, 4-pin, straight, D-coded Head B: male connector, RJ45, 8-pin, straight Cable: Ethernet, drag chain use, PUR, shielded, 2 m SSL-2J04-G02ME 6034414 Head A: male connector, M12, 4-pin, angled, D-coded Head B: male connector, RJ45, 8-pin, straight Cable: EtherNet/IP, PUR, halogen-free, shielded, 2 m SSL-2J04-H02ME 6047911 Head A: male connector, M12, 4-pin, straight, B-coded Cable: PROFIBUS DP, terminal resistor STE-END-Q 6021156 DISTANCE SENSORS | SICK Online data sheet | 2016-05-02 22:08:07 Subject to change without notice Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” Worldwide presence: Contacts and other locations – www.sick.com SICK AG | Waldkirch | Germany | www.sick.com