LinkCom LCCH-150X240 Ac input 100~277vac ovp / otp / scp Datasheet

LinkCom Manufacturing Co., Ltd
Ver B
Model NO.
LCCH-150240
Model Name
Power Supply
Part NO.
PLCCH1150240
SIZE
208.4mm*72mm*38.5mm
FEATURES
◆ AC Input 100~277Vac
◆ Protection: OVP / OTP / SCP
◆ High Operating ambient Temp: -25℃ ~ +60℃
◆ Power Factor:>0.98@115Vac;>0.95@230Vac;@full load
◆ Safety: UL / TUV / CB / PSE
◆ EMC: CE / FCC
◆ Comply with Indoor/Outdoor Waterproof (IP 67)
◆ Dimension (mm): L*W*H: 208.4mm*72mm*38.5mm
◆ ROHS
Module : LCCH-150240
*(9)
*,# =SEE NOTES BELOW
LCCH-150240
MODEL
min.
SPECIFICATION
OPERATING VOLTAGE RANGE(V)
*
*
*
*
*
norm.
PRESET ACCURACY (%) *(8)
1
OUTPUT CURRENT(A) *(5)
6.3
O/P NOISE (P-P, mV) *(3)
250
1
LINE REGULATION (%) *(7)
1
LOAD REGULATION (%) *(6)
151.2 W
DC OUTPUT POWER
EFFICIENCY(typ @Full Load)
91%
SETUP,RISE TIME(typ.)
2S,500ms at full load 115VAC/230VAC
HOLD UP TIME
25ms at full load 115VAC/230VAC
INPUT VOLTAGE RANGE
90-305VAC, 127-431VDC, Normal:100-277VAC
INPUT FREQUENCY
Range:47-63Hz, Normal:50-60Hz
ACTIVE POWER FACTOR
PF>0.98 @115VAC, PF>0.95@230VAC at full load and rated output voltage
INRUSH CURRENT (typ)
COLD START 65A @ 230VAC
AC CURRENT
2.4A/115VAC 1.2A/230VAC
LEAKAGE CURRENT
SHORT CIRCUIT PROTECTION
<0.45mA/264VAC
short circuit protection will restart automatically after the fault condition is removed
OVER TEMP. PROTECTION
OVER V, PROTECTION
*
max.
24
18
shut down and latch off o/p voltage , re-power on to recover
OPERATING TEMP.*(4)
-25 to +60℃@full load
STORAGE TEMPERATURE
-40 to +80℃
RELATIVE HUMIDITY
10 to +90%, non-cond.
0.03% / ℃ (0-50℃, typ)
TEMP. COEFFICIENT
SAFETY
UL 60950-1 / TUV EN61347-2-13 / CB / PSE
EMI
CE EN55015 / FCC Part15
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC, O/P-Grnd:0.5KVAC, I/P-Grnd:1.88KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG,O/P-FG :100M Ohms / 500VDC / 25℃ / 70% RH
DIMENSIONS
208.4mm*72mm*38.5mm(L*W*H)
NOTES:(1)All parameters not specially mentioned are measured 230VAC input.
(2)All specifications Typical @25℃, unless otherwise noted, at normal line and load.
(3)Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth.
(4)Specified for free-air convection cooling.
(5)Minimum load is NOT required for proper operation .
(6)Load regulation measured from 20% to Full load.
(7)Line regulation measured from 100VAC to 277VAC.
(8)Preset accuracy measured at normal load, 120VAC input.
(9)100% Production Tested.
※Reference
www.linkcom.com.tw For more information, please contact with: [email protected]
LinkCom Manufacturing Co., Ltd
Ver B
Model NO.
LCCH-150240
Model Name
Power Supply
Part NO.
PLCCH1150240
SIZE
208.4mm*72mm*38.5mm
DERATE
Dimensions
Unit :mm
※Reference
www.linkcom.com.tw For more information, please contact with :[email protected]
Similar pages