TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ 030AAC Highlights & Features – – – – – – – – – – – MDS-030AAC05, 12, 15, 24 Meet Efficiency Level VI MDS-030AAC07 Meet Efficiency Level V Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1 Compliant with IEC 60601-1-2 4th Ed. Requirements Meets Limited Power Source (LPS) requirements Low touch current. Suitable for type BF applications Detachable AC plug with multiple country options IP22 ingress protection rating 2 × MOPP isolation 500K hours MTBF 3 years warranty Safety Standards CB Certified for worldwide use Model Number: MDS-030AAC☐ Unit Weight: 150 grams Dimensions (W × L × H): 53.5 × 88.0 × 27.5 mm 2.11 × 3.46 × 1.08 inch General Description The MDS series of external power supply comes with universal AC input at 85Vac to 264Vac. Other features include low touch current, risk management report available and the electric shock protection comply with 2 × MOPP. The MDS series is certified for EMC standards according to EN 55011 for industrial, scientific and medical (ISM) radio-frequency equipment and EN 55022 for Information Technology Equipment (ITE) radio-frequency equipment. In addition, only recognized Japanese capacitors are used. The MDS series come with both medical and ITE safety approvals including UL/cUL and IEC-60950-1 CB certification as a Limited Power Source (LPS), and CCC approval. Designs are fully compliant with RoHS Directive 2011/65/EU for environmental protection. Model Information Medical AC-DC Adapter Model Number MDS-030AAC05 Input Voltage Range Efficiency Level 85-264Vac Level VI Rated Output Voltage 5Vdc Rated Output Current 3A MDS-030AAC07 Level V 7Vdc 3A MDS-030AAC12 Level VI 12Vdc 2A MDS-030AAC15 Level VI 15Vdc 2A MDS-030AAC24 Level VI 24Vdc 1.25A Model Numbering MDS – Delta Medical Power Supply 030 Max wattage in the product series AAC Family Code Output Voltage (Single Output) 1 Revision Code 2 Revision Code - 05 for 5V DC plug type and output cable length Country duck-head type - 07 for 7V A:China ; B:United States; - 12 for 12V A:2.1 x 5.5 x10mm DC plug B:2.1 x 5.5 x12mm DC plug - 15 for 15V Both A & B are 1200mm cable length E:Australia; G:Korea; H: India, - 24 for 24V C:European; D:United Kingdom; J :Argentina ; K:Brazil; M:South Africa * MDS-030AAC15 BB is not available. 1 All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (May 2017, Rev.07) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ Specifications Model Number MDS-030AAC05 MDS-030AAC07 MDS-030AAC12 MDS-030AAC15 MDS-030AAC24 Input Ratings / Characteristics Nominal Input Voltage 100-240Vac Input Voltage Range 85-264Vac Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz Input Current (max) Average Efficiency (min) 115Vac 0.5A 0.6A 0.8A 0.8A 0.8A 230Vac 0.3A 0.4A 0.6A 0.6A 0.6A 81.4% 81.4% 86.21% 87.0% 87.0% 0.1W 0.1W 0.1W 0.1W 0.1W 115Vac 230Vac Standby Power (max) 115Vac 230Vac Inrush Current (typ.) 60A @ 115Vac and 100A @ 230Vac Touch Current (max) 0.1mA @ 264Vac NC , 0.3mA @ 264Vac SFC Output-PE (protective earth) leakage current for Type BF application (max) 0.1mA @ 264Vac NC , 0.5mA @ 264Vac SFC 1) 2) 1) 2) 1) 2) NC: Normal condition SFC: Single fault condition Model Number MDS-030AAC05 MDS-030AAC07 MDS-030AAC12 MDS-030AAC15 MDS-030AAC24 Output Ratings / Characteristics Nominal Output Voltage 5Vdc 7Vdc 12Vdc Output Total Regulation 15Vdc 24Vdc ±6% Output Current 3A 3A 2A 2A 1.25A Output Power 15W 21W 24W 30W 30W Line Regulation ±1% Load Regulation ±5% Ripple & Noise (max) 100mVpk-pk @ Rated load 100mVpk-pk @ Rated load 150mVpk-pk @ Rated load 200mVpk-pk @ Rated load 200mVpk-pk @ Rated load Start-up Time (max) 3000ms @ 115Vac Hold-up Time (min) 10ms @ 115Vac Dynamic Response (Overshoot & Undershoot O/P Voltage) ±10% @ 50-100% load Capacitive load (max) 4700uF *Periodic and Random Deviation. Ripple & Noise measurement circuit with 20MHz BW 2 All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (May 2017, Rev.07) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ Model Number MDS-030AAC05 MDS-030AAC07 MDS-030AAC12 MDS-030AAC15 MDS-030AAC24 Mechanical Case Chassis PC Case Cover PC Dimensions (W × L × H) 53.5 × 88.0 × 27.5 mm (2.11 × 3.46 × 1.08 in) Unit Weight 150 grams (5.3 ounces) Indicator NA Cooling System NA Terminal Input Detachable type AC plug Output Barrel type. Dimensions 2.1 × 5.5 × 10 mm (see page 5) Environment Surrounding Air Temperature Operating 0°C to +40°C Storage -40°C to +85°C Operating Humidity 5 - 95% RH (Non-Condensing) Operating Altitude 5,000 meters (16400 feet) Shock Test (Non-Operating) 50G, 11ms, 3 shocks for each direction Vibration (Operating) 5-500Hz, 2.09Grms, 20 minute for each three axis Protections Overvoltage (max) 150%, Latch Mode Overload / Overcurrent (max) 250% of rated load current, Hiccup Mode, (Non-Latching, Auto-Recovery) Hiccup Mode, (Non-Latching, Auto-Recovery) Over Temperature Short Circuit Hiccup Mode, (Non-Latching, Auto-Recovery) Degree of Protection IP22 Protection Against Shock Class II Reliability Data MTBF (min) 3 500K Hours based on Telecordia SR-332 (at 100Vac, Max. load and 25°C Ambient) All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (May 2017, Rev.07) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ Model Number MDS-030AAC05 MDS-030AAC07 MDS-030AAC12 MDS-030AAC15 MDS-030AAC24 Safety Standards / Directives Medical Safety IEC60601-1 Edition 3.1 (2012), EN60601-1 (2006) + A11 + A1 + A12, CAN/CSA-C22.2 NO. 60601-1:14, ANSI/AAMI ES60601-1:2005/(R)2012 UL60601-1 (File No. E356265) ITE Safety IEC60950-1 (Ed.2,2005), GB4943.1-2011, GB9254-2008, GB17625.1-2003 UL60950-1 (File No. E131881), LPS (Limited Power Source) MDD Directive 93/42/EEC CE Material and Parts Galvanic Isolation RoHS Directive 2011/65/EU Compliant Input to 4000 Vac Output EMC (Compliant with IEC 60601-1-2 4th Ed. Requirements) EMC / Emissions Harmonic Current Emissions EN55011/EN55022,FCC Title 47:Class B IEC61000-3-2 Immunity to Voltage Flicker IEC61000-3-3 Electrostatic Discharge IEC61000-4-2 Level 4 Criteria A Air Discharge: 15kV Contact Discharge: 8kV Radiated Field IEC61000-4-3 Criteria A 80MHz-2700MHz, 10V/m AM modulation 385MHz-5785MHz, 28V/m Pulse mode and other modulation Electrical Fast Transient / Burst IEC61000-4-4 Level 3 Criteria A : 2kV Surge IEC61000-4-5 Conducted IEC61000-4-6 Level 3 Criteria A 3) Differential Mode : 1kV 1) Level 2 Criteria A 150kHz-80MHz, 3Vrms, 6Vrms at ISM bands and Amateur radio bands Power Frequency Magnetic Fields IEC61000-4-8 Voltage Dips IEC61000-4-11 1) 1) 1) 1) 1) Criteria A Magnetic field strength 30A/m 1) Criteria A 0% UT, 0.5 cycle (10ms) o o o o o o o o o , 0 /45 /90 /135 /180 /225 /270 /315 /360 2) Criteria B o 0% UT, 1 cycle (20ms), 0 2) Criteria B o 70% UT, 25 cycle (500ms), 0 2) Criteria B o 0% UT, 250 cycle (5000ms), 0 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restore to normal operation after test. 3) Symmetrical: Differential mode (Line to line) Block Diagram 4 All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (May 2017, Rev.07) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ Dimensions W × H × H: 53.5 × 88.0 × 27.5 mm Note: The plug’s polarity is 5 All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (May 2017, Rev.07) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ Duck Head Type: 6 CN type US/JP type EU type UK type AU KR type IN type AR type BZ type SA type All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (May 2017, Rev.07) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ Functions Start-up Time The time required for the output voltage (Vo) to reach 90% of its set value, after the input AC voltage is applied. Rise Time The time required for the output voltage (Vo) to change from 10% to 90% of its steady state value. Hold-up Time Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time required for the output to reach 95% of its set value, after the input voltage is removed. Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Inrush Current Dynamic Response Inrush current is the input current that occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. The power supply output voltage will remain within ±3% of its steady state value, when subjected to a dynamic load change from 50 to 100% of its rated current. 7 All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (May 2017, Rev.07) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ Overload & Over current Protections Overvoltage Protection The power supply’s Overload (OLP) and Over current (OCP) Protections will be activated when output current is between 110% and 250% of IO (Max load). Upon such an occurrence, VO will start to drop. Once the power supply has reached its maximum power limit, the protection will be activated and the power supply will go into “Hiccup mode” (Auto-Recovery). The power supply will recover once the fault condition causing the OLP and OCP is removed and IO is back within the specified limit. The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”. Power supply will latch off, and require removal/re-application of input AC voltage in order to restart. Over Temperature Protection As mentioned above, the power supply also has Over Temperature Protection (OTP). This is activated when the overload condition persists for an extended duration and the output current is below the overload trigger point but >100% load. In the event of a higher operating condition at 100% load, the power supply will run into OTP when the surrounding air temperature is higher than the operating temperature. When activated, the output voltage will go into hiccup mode until the input voltage is removed; then, reapplied, and the surrounding air temperature drops to its normal operating temperature. Additionally, if the IO is <250% but >110% for a prolong period of time (depending on the load), the Over Temperature Protection (OTP) will be activated due to high temperature on critical components. The power supply will then go into hiccup mode until the fault is removed; and, the input voltage is removed, then reapplied. Short Circuit Protection (Auto-Recovery) The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. 8 All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (May 2017, Rev.07) TECHNICAL DATASHEET Medical AC-DC Adapter MDS-030AAC Series / MDS-030AAC□ Certificate All Delta Medical Power products conform to the European directive 2011/65/EU. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances. Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs. Frequently, the user does not profit from fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a specific application. In addition to a UL Total Certification Program (TCP) approved client laboratory for IEC60950 and IEC60065. Delta also has participated UL Client Test Data Program (CDTP) for IEC 60601. Meet Level V Efficiency Requirement for MDS-030AAC07 Meet Level VI Efficiency Requirement for MDS-030AAC05, 12, 15, 24 Meets Limited Power Source (LPS) requirement 9 All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (May 2017, Rev.07)