MPD A125HI A100hi sery Datasheet

A100HI Series
Ultra-High Isolation, 1.5W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 1.5W Output Power
• 8,000 VDC Isolation
• 2 µA Leakage Current Max
• Compact DIP Case
• Single & Dual Outputs
• Meets EN55022 Class A
• 1.0 MH MTBF
• Industry Standard Pin-Out
Input
Parameter
Conditions
Input Voltage Range
Input Filter
Reverse Polarity Input Current
Short Circuit Input Power
Output
Parameter
Min.
Typ.
Max.
Units
5 VDC Input
4.5
12 VDC Input 10.8
15 VDC Input 13.5
 (Pi) Filter
5.0
12.0
15.0
5.5
13.2
16.5
VDC
0.5
1,000
A
mW
Typ.
Max.
Units
±2.0
Dual Output , Balanced Loads
±0.5
For Vin Change of 1%
±1.2
See Model Selection Guide
30
Over Line, Load & Temp.
±4.0
±2.0
±1.5
%
%
%
40
50
15
Conditions
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, (Note 1)
Ripple & Noise (20 MHz) (Note 2)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Temperature Coefficient
Output Short Circuit
General
Parameter
Min.
±0.02
Typ.
Max.
Units
120
Continuous
Conditions
Isolation Voltage, Rated
Isolation Test Voltage
Leakage Current
Isolation Resistance
Isolation Capacitance
Switching Frequency
±0.01
mV P - P
mV P - P
mV rms
%
%/ºC
Min.
60 Seconds
Flash Tested For 1 Second
240 VAC, 60 Hz
500 VDC
100 kHz, 1V
8,000
8,800
10
15
100
VDC
VDC
µA
G
pF
kHz
Typ.
Max.
Units
+85
+95
+125
ºC
ºC
ºC
95
%
2
10
50
Environmental
Parameter
Conditions
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Min.
Ambient
Case
-40
-40
-55
Free Air Convection
RH, Non-condensing
Physical
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Case Size
Case Material
Weight
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)
Non-Conductive Black Plastic (UL94-V0)
0.42 Oz (12g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Conditions
5 VDC Input
12 VDC Input
15 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
Typ.
Max.
2.0
Min.
Units
MHours
Typ.
-0.7
-0.7
-0.7
Max.
7.0
17.0
21.0
260
1,000
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
ºC
mW
www.micropowerdirect.com
Model Selection Guide
Model
Number
A101HI
A102HI
A103HI
A104HI
A105HI
A106HI
A111HI
A112HI
A113HI
A114HI
A115HI
A116HI
A121HI
A122HI
A123HI
A124HI
A125HI
A126HI
Input
Voltage (VDC)
Nominal
Range
5
5
5
5
5
5
12
12
12
12
12
12
15
15
15
15
15
15
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
Current (mA)
Full-Load No-Load
400
400
400
400
400
400
167
167
167
167
167
167
133
133
133
133
133
132
50
50
50
50
50
50
30
30
30
30
30
30
30
30
30
30
30
30
Reflected
Output
Fuse Rating
Load
Efficiency
Ripple
Slow-Blow
Voltage Current
Current Regulation
(%, Typ)
Current
(%, Max))
(mA)
(VDC)
(mA,
Max)
(mA,
Min)
(mA, Typ)
30
30
30
30
30
30
25
25
25
25
25
25
20
20
20
20
20
20
5.0
12.0
15.0
±5.0
±12.0
±15.0
5.0
12.0
15.0
±5.0
±12.0
±15.0
5.0
12.0
15.0
±5.0
±12.0
±15.0
Notes:
1. When measuring output ripple, it is recommended that an external 0.33 µF ceramic
capacitor be placed from the +Vout pin to the -Vout pin for single output units and from
each output to common for dual output units. For noise sensitive applications, the use of
1.5 µF capacitors will reduce the output ripple.
2. Transient recovery is measured to within a 1% error band for a load step change of 50%
to 100%.
3. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do
this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float
the output common.
4. The converter should be connected to a low ac-impedance source. An
input source with a highly inductive impedance may affect the stability of
the converter. In applications where the converter output loading is high
and input power is supplied over long lines, it may be necessary to use a
capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz)
capacitor be mounted close to the converter. For 5V input units a 2.2 µF
is recommended, a 1.0 µF for 12V units and a 0.47 µF for 24V units.
5. It is recommended that a fuse be used on the input of a power supply for
protection. See the table above for the correct rating.
300
125
100
±150
±63
±50
300
125
100
±150
±63
±50
300
125
100
±150
±63
±50
0.0
0.0
0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
±10
±8
±6
±12
±8
±6
±10
±8
±6
±12
±8
±6
±10
±8
±6
±12
±8
±6
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
1,000
1,000
1,000
1,000
1,000
1,000
250
250
250
250
250
250
250
250
250
250
250
250
Derating Curve
Capacitive Load
Single Output Dual Output
(µF Max)
(µF Max)
470
Mechanical Dimensions
±220
Pin Connections
Pin
Single
Dual
1, 2
+Vin
+Vin
11, 12
+Vout
+Vout
13, 14
-Vout
Common
15
No Pin
-Vout
23, 24
-Vin
-Vin
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]