Dallas DS1100-500 5-tap economy timing element delay line Datasheet

DS1100
5-Tap Economy Timing
Element (Delay Line)
www.maxim-ic.com
PIN ASSIGNMENT
FEATURES
§
§
§
§
§
§
§
§
§
§
§
§
All-Silicon Timing Circuit
Five Taps Equally Spaced
5V Operation
Delays are Stable and Precise
Both Leading- and Trailing-Edge Accuracy
Improved Replacement for DS1000
Low-Power CMOS
TTL/CMOS-Compatible
Vapor-Phase, IR, and Wave Solderable
Custom Delays Available
Fast-Turn Prototypes
Delays Specified Over Both Commercial and
Industrial Temperature Ranges
IN
1
8
VCC
TAP 2
2
7
TAP 1
TAP 4
3
6
TAP 3
GND
4
5
TAP 5
DS1100M DIP (300mil)
DS1100Z SO (150mil)
DS1100U µSOP
PIN DESCRIPTION
TAP 1 to TAP 5
VCC
GND
IN
- TAP Output Number
- +5V
- Ground
- Input
DESCRIPTION
The DS1100 series delay lines have five equally spaced taps providing delays from 4ns to 500ns. These
devices are offered in 8-pin DIPs and surface-mount packages to save PC board area. Low cost and
superior reliability over hybrid technology is achieved by the combination of a 100% silicon delay line
and industry-standard DIP and SO packaging. The DS1100 5-tap silicon delay line reproduces the inputlogic state at the output after a fixed delay as specified by the extension of the part number after the dash.
The DS1100 is designed to reproduce both leading and trailing edges with equal precision. Each tap is
capable of driving up to ten 74LS loads.
Dallas Semiconductor can customize standard products to meet special needs.
1 of 6
091202
DS1100
Figure 1. LOGIC DIAGRAM
Table 1. DS1100 PART NUMBER DELAY TABLE (All Values in ns)
PART
DS1100-XXX
-20
-25
-30
-35
-40
-45
-50
-60
-75
-100
-125
-150
-175
-200
-250
-300
-500
TAP 1
4
5
6
7
8
9
10
12
15
20
25
30
35
40
50
60
100
TAP 2
8
10
12
14
16
18
20
24
30
40
50
60
70
80
100
120
200
NOMINAL DELAYS
TAP 3
12
15
18
21
24
27
30
36
45
60
75
90
105
120
150
180
300
Figure 2. TIMING DIAGRAM: SILICON DELAY LINE
2 of 6
TAP 4
16
20
24
28
32
36
40
48
60
80
100
120
140
160
200
240
400
TAP 5
20
25
30
35
40
45
50
60
75
100
125
150
175
200
250
300
500
DS1100
ABSOLUTE MAXIMUM RATINGS*
Voltage on Any Pin Relative to Ground
Operating Temperature Range
Storage Temperature Range
Soldering Temperature
Short-Circuit Output Current
-0.5V to +6.0V
-40°C to +85°C
-55°C to +125°C
See IPC/JEDEC J-STD-020A Specification
50mA for 1s
*This is a stress rating only and functional operation of the device at these or any other conditions above
those indicated in the operation sections of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods of time may affect reliability.
DC ELECTRICAL CHARACTERISTICS (VCC = 5.0V ±5%, TA = -40°C to +85°C.)
PARAMETER
Supply Voltage
High-Level
Input Voltage
Low-Level
Input Voltage
Input-Leakage
Current
Active Current
High-Level
Output Current
Low-Level
Output Current
SYM
VCC
TEST CONDITION
MIN
4.75
TYP
5.00
MAX
5.25
VCC +
0.3
UNITS
V
NOTES
5
V
5
5
VIH
2.2
VIL
-0.3
0.8
V
-1.0
1.0
µA
50
mA
-1
mA
II
0.0V £ VI £ VCC
ICC
VCC = Max; Freq = 1MHz
IOH
VCC = Min; VOH = 4
IOL
VCC = Min; VOL = 0.5
30
12
6, 8
mA
AC ELECTRICAL CHARACTERISTICS (VCC = 5.0V ±5%, TA = -40°C to +85°C.)
PARAMETER
Input
Pulse Width
Input-to-Tap
Delay Tolerance
(Delays £ 40ns)
Input-to-Tap
Delay Tolerance
(Delays > 40ns)
Power-Up Time
Input Period
SYM
TEST CONDITION
tWI
tPLH,
tPHL
tPLH,
tPHL
+25°C 5V
0°C to +70°C
-40°C to +85°C
+25°C 5V
0°C to +70°C
-40°C to +85°C
tPU
Period
MIN
20% of
Tap 5
tPLH
-2
-3
-4
-5
-8
-13
TYP
Table 1
Table 1
Table 1
Table 1
Table 1
Table 1
MAX
UNITS
NOTES
ns
9
ns
ns
ns
%
%
%
µs
ns
1, 3, 4, 7
1, 2, 3, 4, 7
1, 2, 3, 4, 7
1, 3, 4, 7
1, 2, 3, 4, 7
1, 2, 3, 4, 7
+2
+3
+4
+5
+8
+13
200
2(tWI)
CAPACITANCE
PARAMETER
Input Capacitance
9
(TA = +25°C)
SYMBOL
CIN
MIN
TYP
5
3 of 6
MAX
10
UNITS
pF
NOTES
DS1100
NOTES:
1) Initial tolerances are ± with respect to the nominal value at +25°C and 5V for both leading and
trailing edge.
2) Temperature and voltage tolerance is with respect to the nominal delay value over the stated
temperature range, and a supply-voltage range of 4.75V to 5.25V.
3) All tap delays tend to vary unidirectionally with temperature or voltage changes. For example, if
TAP1 slows down, all other taps also slow down; TAP3 can never be faster than TAP2.
4) Intermediate delay values are available on a custom basis. For further information, call
(972) 371-4348.
5) All voltages are referenced to ground.
6) Measured with outputs open.
7) See Test Conditions section at the end of this data sheet.
8) Frequencies higher than 1MHz result in higher ICC values.
9) At or near maximum frequency the delay accuracy can vary and will be application sensitive (i.e.,
decoupling, layout).
Figure 3. TEST CIRCUIT
4 of 6
DS1100
TERMINOLOGY
Period: The time elapsed between the leading edge of the first pulse and the leading edge of the
following pulse.
tWI (Pulse Width): The elapsed time on the pulse between the 1.5V point on the leading edge and the
1.5V point on the trailing edge, or the 1.5V point on the trailing edge and the 1.5V point on the leading
edge.
tRISE (Input Rise Time): The elapsed time between the 20% and the 80% point on the leading edge of the
input pulse.
tFALL (Input Fall Time): The elapsed time between the 80% and the 20% point on the trailing edge of the
input pulse.
tPLH (Time Delay, Rising): The elapsed time between the 1.5V point on the leading edge of the input
pulse and the 1.5V point on the leading edge of any tap output pulse.
tPHL (Time Delay, Falling): The elapsed time between the 1.5V point on the trailing edge of the input
pulse and the 1.5V point on the trailing edge of any tap output pulse.
TEST SETUP DESCRIPTION
Figure 3 illustrates the hardware configuration used for measuring the timing parameters on the DS1100.
The input waveform is produced by a precision-pulse generator under software control. Time delays are
measured by a time interval counter (20ps resolution) connected between the input and each tap. Each tap
is selected and connected to the counter by a VHF switch control unit. All measurements are fully
automated, with each instrument controlled by a central computer over an IEEE 488 bus.
TEST CONDITIONS INPUT :
Ambient Temperature:
Supply Voltage (VCC):
Input Pulse:
Source Impedance:
Rise and Fall Time:
Pulse Width:
Period:
+25°C ±3°C
5.0V ±0.1V
High = 3.0V ±0.1V
Low = 0.0V ±0.1V
50W max
3.0ns max (measured between 0.6V and 2.4V)
500ns (1µs for -500 version)
1µs (2µs for -500 version)
OUTPUT:
Each output is loaded with the equivalent of one 74F04 input gate. Delay is measured at the 1.5V level on
the rising and falling edge.
NOTE:
Above conditions are for test only and do not restrict the operation of the device under other data sheet
conditions.
5 of 6
DS1100
ORDERING INFORMATION
DS1100
TOTAL TIME DELAY (ns): 20,
25, 30, 35, 40, 45, 50, 60, 75,
100, 125, 150, 175, 200, 250,
300, 500
PACKAGE TYPE:
M = DIP
Z = SO (150MIL)
U = µSOP
EXAMPLE: The DS1100Z-250 is a 250ns delay (input-to-tap 5) DS1100 in the SO package.
6 of 6