LO10-26D0512-04 Three-phase three wire or four wire open frame switched-mode power supply High isolated, ultra wide input voltage range AC-DC converter for electric meters Ultra wide input voltage range open frame switched-mode power supply for electric-meter application This AC-DC converter is designed for electric-meter application and operates over a very wide input voltage range: 65-460VAC or 90-650VDC. It means that this converter can operate with any two wires connection from the three-phase three wire or four-wire system. When failures happen in the lines system resulting in input over-voltage, the converter will shut down to protect itself and the RoHS terminal devices from damage, improving the reliability of the system. The isolation voltage is 4000VAC between input and output, and two outputs. The product meets IEC/EN61000 "Burst (4kV)", "Surge (2kV)" and "EN55022 Class B Conduction/ Radiation". So it is a design solution for electric-meter application sourced from a three-phase AC supply with the requirement of high isolation voltage and rigorous EMC. FEATURES 1. Ultra wide input voltage range: 65~460VAC/90~650VDC 2. Any two wires connection from the three-phase three wire or four-wire system is available 3. Conduction/Radiation: Class B 4. Burst/Surge: Class 4 5. Multi-output protection functions: over-current protection, short circuit protection, over-voltage protection 6. Input Under Voltage and over-voltage protection 7. High efficiency, high reliability, low ripple & noise, low standby power consumption 8. Long-life low-impedance electrolytic capacitors 9. Multi-output, customized available PART NUMBER SYSTEM LO10-26D0512-04 S u p p le m e n t O u tp u t t C u rre n t S u p p le m e n t O u tp u t Vo lta g e ma in o utp ut O u tp u t Vo lt a g e Output Style Input Voltage Isolation Voltage Output Power Package Styl e Produc t Seri es SELECTION GUIDE Model Power (W) LO10-26D0512-04 10.92 Output (Vo1/Io1) (Vo2/Io2) EFFICIENCY (%) (220VAC,typ) Standby Power (220VAC,typ) 5.1VDC/1.2A 12VDC/0.4A 78 0.55W INPUT SPECIFICATIONS Item Test Conditions Min. Typ. Max. 65 -- 460 DC Input 90 -- 650 AC Input 470 -- 540 Input Frequency 47 -- 440 Hz Input Current -- -- 0.4 A Unit AC Input Input Voltage Range Input over-voltage Protection Unit V OUTPUT SPECIFICATIONS Item Test Conditions Output Voltage Accuracy Balance load Line Regulation Full load Load Regulation (10% to 100%)Balance load Min. Typ. Max. Main output(Vo1) -- ±2 -- Secondary output(Vo2) -- ±10 -- Main output(Vo1) -- ±0.5 -- Secondary output(Vo2) -- ±1.5 -- Main output(Vo1) -- ±3 -- Secondary output(Vo2) -- ±5 -- The copyright and authority for the interpretation of the products are reserved by MORNSUN % Specifications subject to change without notice. LO10-26D0512-04 2013.04.26-A/1 Page 1 of 4 Ripple& Noise(p-p) 20MHz bandwidth Main output(Vo1) -- -- 100 Secondary output(Vo2) -- -- 200 Min Load Capacitor load max 10 -- -- Main output(Vo1) -- 4000 -- Secondary output(Vo2) -- 1200 -- -- 200 -- Hold-up Time Short Circuit Protection Continuous, and auto recovery Over Current Protection 110~250% Io and auto recovery Over Voltage Protection Feedback-clamp mV % µF ms COMMON SPECIFICATIONS Item Test Conditions Min. Typ. Max. Operating Temperature -40 -- +70 Storage Temperature -40 -- +85 Power derating -40℃~0℃ 0.75 -- -- +60℃~+70℃ 3.00 -- -- 100 -- -- input-output1 and output 2 4000 -- -- 4000 -- -- Isolation Resistance Isolation Voltage Tested for 1 minute output 1- output 2 Storage Humidity Temperature coefficient 20 -- 90 Main output(Vo1) -- ±0.02 -- Secondary output(Vo2) -- ±0.06 -- Unit ℃ %/℃ MΩ VAC %RH %/℃ Altitude -- -- 9000 m Switching Frequency -- 65 -- kHz Safety approvals -- Safety Class CLASS Ⅱ Safety standards -- Hot swap Forbid Vibration 10~55Hz,19.6m/s (2G),3min; X,Y,Z 1 time 2 2 Shock 196.1m/s (2G),11ms; X,Y,Z axis 1 time Weight 95g Outline size 100mm(L)×50mm(W)×35mm(H) Install PCB Cooling Free air convection MTBF >300,000 h @ 25℃ Note:1. Ripple and Noise are measured by the method of parallel lines; 2. Unless otherwise specified, all specifications above are measured at rated input voltage and rated output load, Ta=25℃, humidity < 75%. 3.The output voltage will drop when over current protection start up, coming into hiccup protection state, and it can auto resume normal operating when the malfunction is eliminated. EMC SPECIFICATIONS EMI CE CISPR22/EN55022, CLASS B(without external circuit ) RE CISPR22/EN55022, CLASS B(without external circuit ) ESD IEC/EN61000-4-2 ±6KV/8KV perf. Criteria B RS IEC/EN61000-4-3 10V/m perf. Criteria A IEC/EN61000-4-4 ±4KV(without external circuit ) IEC/EN61000-4-4 ±4.4KV IEC/EN61000-4-5 ±2KV(without external circuit ) IEC/EN61000-4-5 ±4.4KV CS IEC/EN61000-4-6 10 Vr.m.s perf. Criteria A PFM IEC/EN61000-4-8 10A/m perf. Criteria A Voltage dips, short and interruptions immunity IEC/EN61000-4-11 EFT EMS Surge (External Circuit Refer to Figure 2,3) (External Circuit Refer to Figure 2,3) 0%-70% The copyright and authority for the interpretation of the products are reserved by MORNSUN perf. Criteria B perf. Criteria B perf. Criteria B Specifications subject to change without notice. LO10-26D0512-04 2013.04.26-A/1 Page 2 of 4 PARALLEL LINES MEASURE Copper sheet F USE AC (L) AC ( L) +Vo AC (N ) A C (N ) C2 C1 AC/DC Connect Oscillograph P robe Load -Vo 12.7mm 25.4mm 25 . 4 m m Note: C1: 1µF (Ceramic capacitor) C2: 10µF (Electrolytic capacitor) PRODUCT TYPICAL CURVE Efficiency VS Input Voltage curve (Full Load) Efficiency VS Output Load curve (Vin=220VAC) 85 95 90 80 85 Efficiency(%) Efficiency(%) 90 75 70 65 60 80 75 70 65 60 55 55 50 50 65 85 110 220 380 460 10 Input Voltage(VAC) O u tp ut P ow e r Pe r ce nt (% ) Output Power Percent(%) 100 70 Input voltage:85~460VAC 0 -25 0 10 20 30 40 30 40 50 60 70 80 90 100 Total Output Current (%) Temperature Derating Graph -40 20 50 60 70 Ambient Tem.(℃) Note: When input 65~85VAC, it need to be voltage derated on basis of temperature derating. Input Voltage Derating Graph 100 80 60 Ambient temperature:25℃ 40 65 85 460 Input Voltage( VAC) Note: When input DC, VDC=1.414*VAC-20. TYPICAL APPLICATIONS Note: AC(L) AC(N) FUSE AC(L) + Vo1 + Vo2 AC(N) - C1 C2 TVS RL Output filtering capacitors C2,C4 is electrolytic capacitors, It is recommended to use high frequency and low impedance electrolytic capacitors. Recommended value (C2:220µF/10V; C4:100µF/25V); C1,C3 are ceramic capacitors and they used to filter high frequency noise, Recommend value:0.1µF/50V, It is recommended that the C3 C4 RL Figure1: Typical application circuit for LO10-26D0512-04 5.1V main output circuit adds TVS to protect post-circuits (if converter fails);and the 12V supplement output circuit has had TVS inside so it needs no external TVS. EMC RECOMMENDED CIRCUIT Figure 2:Recommended circuit for applications which require 4.4KV differential-mode inrush standard (full-wave rectification) The copyright and authority for the interpretation of the products are reserved by MORNSUN Specifications subject to change without notice. LO10-26D0512-04 2013.04.26-A/1 Page 3 of 4 Figure 3:Recommended circuit for applications which require 4.4KV differential-mode inrush standard (half-wave rectification) If higher EMC requirement ,please refer to figure 2.3, recommended parameters are shown in the table below. Recommend Parameter For Higher EMC Standard Circuit Components Recommend Parameter MOV CX LDM S20K550 0.15µF 56µH LCM 3mH C1、C2 47µF/400VDC R4、R5、R6、R7 560kΩ/1206 D R1、R2、R3 2A/1000V 5Ω/5W FUSE 3.15A/250V,slow blow, it must be connected to FUSE DIMENSIONS, RECOMMENDED FOOTPRINT&PACKAGING MORNSUN Science & Technology Co.,Ltd. Address: No. 5, Kehui St. 1, Kehui development center, Science Ave., Guangzhou Science City, Luogang district, Guangzhou,P.R.China. Tel: 86-20-38601850 Fax:86-20-38601272 E-mail: [email protected] Http://www.mornsun-power.com The copyright and authority for the interpretation of the products are reserved by MORNSUN Specifications subject to change without notice. LO10-26D0512-04 2013.04.26-A/1 Page 4 of 4