MORNSUN LO10-26D0512-04 Ac-dc converter for electric meter Datasheet

LO10-26D0512-04
Three-phase three wire or four wire open frame
switched-mode power supply
High isolated, ultra wide input voltage range
AC-DC converter for electric meters
Ultra wide input voltage range open frame switched-mode power supply for electric-meter
application
This AC-DC converter is designed for electric-meter application and operates over a very wide
input voltage range: 65-460VAC or 90-650VDC. It means that this converter can operate with any
two wires connection from the three-phase three wire or four-wire system. When failures happen in
the lines system resulting in input over-voltage, the converter will shut down to protect itself and the
RoHS
terminal devices from damage, improving the reliability of the system. The isolation voltage is
4000VAC between input and output, and two outputs. The product meets IEC/EN61000 "Burst
(4kV)", "Surge (2kV)" and "EN55022 Class B Conduction/ Radiation". So it is a design solution for
electric-meter application sourced from a three-phase AC supply with the requirement of high
isolation voltage and rigorous EMC.
FEATURES
1. Ultra wide input voltage range: 65~460VAC/90~650VDC
2. Any two wires connection from the three-phase three wire or four-wire
system is available
3. Conduction/Radiation: Class B
4. Burst/Surge: Class 4
5. Multi-output protection functions: over-current protection, short circuit
protection, over-voltage protection
6. Input Under Voltage and over-voltage protection
7. High efficiency, high reliability, low ripple & noise, low standby power
consumption
8. Long-life low-impedance electrolytic capacitors
9. Multi-output, customized available
PART NUMBER SYSTEM
LO10-26D0512-04
S u p p le m e n t O u tp u t t C u rre n t
S u p p le m e n t O u tp u t Vo lta g e
ma in o utp ut O u tp u t Vo lt a g e
Output Style
Input Voltage
Isolation Voltage
Output Power
Package Styl e
Produc t Seri es
SELECTION GUIDE
Model
Power (W)
LO10-26D0512-04
10.92
Output
(Vo1/Io1)
(Vo2/Io2)
EFFICIENCY (%)
(220VAC,typ)
Standby Power
(220VAC,typ)
5.1VDC/1.2A
12VDC/0.4A
78
0.55W
INPUT SPECIFICATIONS
Item
Test Conditions
Min.
Typ.
Max.
65
--
460
DC Input
90
--
650
AC Input
470
--
540
Input Frequency
47
--
440
Hz
Input Current
--
--
0.4
A
Unit
AC Input
Input Voltage Range
Input over-voltage Protection
Unit
V
OUTPUT SPECIFICATIONS
Item
Test Conditions
Output Voltage Accuracy
Balance load
Line Regulation
Full load
Load Regulation
(10% to 100%)Balance load
Min.
Typ.
Max.
Main output(Vo1)
--
±2
--
Secondary output(Vo2)
--
±10
--
Main output(Vo1)
--
±0.5
--
Secondary output(Vo2)
--
±1.5
--
Main output(Vo1)
--
±3
--
Secondary output(Vo2)
--
±5
--
The copyright and authority for the interpretation of the products are reserved by MORNSUN
%
Specifications subject to change without notice.
LO10-26D0512-04
2013.04.26-A/1
Page 1 of 4
Ripple& Noise(p-p)
20MHz bandwidth
Main output(Vo1)
--
--
100
Secondary output(Vo2)
--
--
200
Min Load
Capacitor load max
10
--
--
Main output(Vo1)
--
4000
--
Secondary output(Vo2)
--
1200
--
--
200
--
Hold-up Time
Short Circuit Protection
Continuous, and auto recovery
Over Current Protection
110~250% Io and auto recovery
Over Voltage Protection
Feedback-clamp
mV
%
µF
ms
COMMON SPECIFICATIONS
Item
Test Conditions
Min.
Typ.
Max.
Operating Temperature
-40
--
+70
Storage Temperature
-40
--
+85
Power derating
-40℃~0℃
0.75
--
--
+60℃~+70℃
3.00
--
--
100
--
--
input-output1 and output 2
4000
--
--
4000
--
--
Isolation Resistance
Isolation Voltage
Tested for 1 minute
output 1- output 2
Storage Humidity
Temperature coefficient
20
--
90
Main output(Vo1)
--
±0.02
--
Secondary output(Vo2)
--
±0.06
--
Unit
℃
%/℃
MΩ
VAC
%RH
%/℃
Altitude
--
--
9000
m
Switching Frequency
--
65
--
kHz
Safety approvals
--
Safety Class
CLASS Ⅱ
Safety standards
--
Hot swap
Forbid
Vibration
10~55Hz,19.6m/s (2G),3min; X,Y,Z 1 time
2
2
Shock
196.1m/s (2G),11ms; X,Y,Z axis 1 time
Weight
95g
Outline size
100mm(L)×50mm(W)×35mm(H)
Install
PCB
Cooling
Free air convection
MTBF
>300,000 h @ 25℃
Note:1. Ripple and Noise are measured by the method of parallel lines;
2. Unless otherwise specified, all specifications above are measured at rated input voltage and rated output load, Ta=25℃, humidity < 75%.
3.The output voltage will drop when over current protection start up, coming into hiccup protection state, and it can auto resume normal operating when
the malfunction is eliminated.
EMC SPECIFICATIONS
EMI
CE
CISPR22/EN55022, CLASS B(without external circuit )
RE
CISPR22/EN55022, CLASS B(without external circuit )
ESD
IEC/EN61000-4-2
±6KV/8KV
perf. Criteria B
RS
IEC/EN61000-4-3
10V/m
perf. Criteria A
IEC/EN61000-4-4
±4KV(without external circuit )
IEC/EN61000-4-4
±4.4KV
IEC/EN61000-4-5
±2KV(without external circuit )
IEC/EN61000-4-5
±4.4KV
CS
IEC/EN61000-4-6
10 Vr.m.s
perf. Criteria A
PFM
IEC/EN61000-4-8
10A/m
perf. Criteria A
Voltage dips, short
and interruptions immunity
IEC/EN61000-4-11
EFT
EMS
Surge
(External Circuit Refer to Figure 2,3)
(External Circuit Refer to Figure 2,3)
0%-70%
The copyright and authority for the interpretation of the products are reserved by MORNSUN
perf. Criteria B
perf. Criteria B
perf. Criteria B
Specifications subject to change without notice.
LO10-26D0512-04
2013.04.26-A/1
Page 2 of 4
PARALLEL LINES MEASURE
Copper sheet
F USE
AC (L)
AC ( L)
+Vo
AC (N )
A C (N )
C2
C1
AC/DC
Connect Oscillograph P robe
Load
-Vo
12.7mm
25.4mm
25 . 4 m m
Note: C1: 1µF (Ceramic capacitor)
C2: 10µF (Electrolytic capacitor)
PRODUCT TYPICAL CURVE
Efficiency VS Input Voltage curve
(Full Load)
Efficiency VS Output Load curve
(Vin=220VAC)
85
95
90
80
85
Efficiency(%)
Efficiency(%)
90
75
70
65
60
80
75
70
65
60
55
55
50
50
65
85
110
220
380
460
10
Input Voltage(VAC)
O u tp ut P ow e r Pe r ce nt (% )
Output Power Percent(%)
100
70
Input voltage:85~460VAC
0
-25
0
10
20
30
40
30
40
50 60
70
80
90 100
Total Output Current (%)
Temperature Derating Graph
-40
20
50 60 70
Ambient Tem.(℃)
Note: When input 65~85VAC, it need to be voltage derated on basis of
temperature derating.
Input Voltage Derating Graph
100
80
60
Ambient temperature:25℃
40
65
85
460
Input Voltage( VAC)
Note: When input DC, VDC=1.414*VAC-20.
TYPICAL APPLICATIONS
Note:
AC(L)
AC(N)
FUSE
AC(L) +
Vo1
+
Vo2
AC(N) -
C1 C2 TVS RL
Output filtering capacitors C2,C4 is electrolytic capacitors, It is
recommended to use high frequency and low impedance electrolytic
capacitors. Recommended value (C2:220µF/10V; C4:100µF/25V);
C1,C3 are ceramic capacitors and they used to filter high frequency
noise, Recommend value:0.1µF/50V, It is recommended that the
C3 C4
RL
Figure1: Typical application circuit for LO10-26D0512-04
5.1V main output circuit adds TVS to protect post-circuits (if
converter fails);and the 12V supplement output circuit has had TVS
inside so it needs no external TVS.
EMC RECOMMENDED CIRCUIT
Figure 2:Recommended circuit for applications which require 4.4KV differential-mode inrush standard (full-wave rectification)
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
LO10-26D0512-04
2013.04.26-A/1
Page 3 of 4
Figure 3:Recommended circuit for applications which require 4.4KV differential-mode inrush standard (half-wave rectification)
If higher EMC requirement ,please refer to figure 2.3, recommended parameters are shown in the table below.
Recommend Parameter For Higher EMC Standard Circuit
Components
Recommend Parameter
MOV
CX
LDM
S20K550
0.15µF
56µH
LCM
3mH
C1、C2
47µF/400VDC
R4、R5、R6、R7
560kΩ/1206
D
R1、R2、R3
2A/1000V
5Ω/5W
FUSE
3.15A/250V,slow blow, it must be connected to
FUSE
DIMENSIONS, RECOMMENDED FOOTPRINT&PACKAGING
MORNSUN Science & Technology Co.,Ltd.
Address: No. 5, Kehui St. 1, Kehui development center, Science Ave., Guangzhou Science City, Luogang district, Guangzhou,P.R.China.
Tel: 86-20-38601850
Fax:86-20-38601272
E-mail: [email protected]
Http://www.mornsun-power.com
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
LO10-26D0512-04
2013.04.26-A/1
Page 4 of 4
Similar pages