RRE NDC-L Standard magnet Datasheet

Test Coils
For Reed Switches and Sensors
Cylindrical
Test Coil No.
A
B
C
D
E
Wire Diameter
Turns
Coil Res. 
Rectangular
Test Coil
A mm
B mm
C mm
D mm
E mm
F mm
G mm
H mm
Wire Diameter mm
Turns
Coil Resistance 
717 102 001
53.3
50.8
7.6
5.6
14.1
0.090
10000
845
717 102 002
717 102 003
21.0
12.0
19.0
10.0
4.3
3.3
3.4
2.3
7.7
11.0
0.050
0.060
5000
5000
740
600
All dimensions in mm
TCP 3001
13.5
7
8
6
14
18
12
10
0.05
5000
2000
TCP3002
23.3
19.7
6.8
6.2
14.8
20.6
12.2
11.6
0.08
10000
1900
717 102 004
27.8
25.4
8.7
2.4
17.2
0.100
5000
404
TCP 3003
42.5
36.5
14.8
13.8
25.0
28.6
14.6
13.6
0.15
5000
290
717 102 005
19.0
15.0
3.7
2.9
11.0
0.071
5000
450
TCP 3004
42.5
36.5
15.8
13.8
25.0
35.6
22.8
20.8
0.15
5000
440
Due to continual improvement, specifications are subject to change without notice
www.reed-sensor.com
6 December 2004
s
Reed Relays and Electronics India Limited  [email protected]  Tel 91-44-6528-4022
Standard Magnets
For Reed Switches and Sensors
Cylindrical Magnets
mm
Part Number
Material
D (mm)
L (mm)
NDC-T
NdFeB:N35
2.0
4.0
NDC-S
NdFeB:N35
3.0
7.0
NDC-M
NdFeB:N35
4.0
10.0
NDC-L
NdFeB:N35
8.0
15.0
Bar Magnets
mm
Part Number
Material
L (mm)
B (mm)
H (mm)
NDR-T
NdFeB:N35
4.0
1.5
1.5
NDR-S
NdFeB:N35
6.0
2.5
2.5
NDR-M
NdFeB:N35
8.0
3.0
3.0
NDR-L
NdFeB:N35
19.0
4.0
4.0
Magnet Material Specifications
Magnet Type
Composition
Ferrite
AlNiCo
NdFeB
NdFeB
SmCo
Code
C8
LNG37
N35
N35SH
YX20
Remanance
Br (mT)
385
1180
1180
1180
925
Coercivity
HcB (kA/m)
235
48
880
880
680
HcJ (kA/m)
242
53
955
1353
1595
Energy Product max.
BH (kJ/m3)
27.8
37
270
270
160
Operating
Temperature
(C)
300
550
80
120
300
Due to continual improvement, specifications are subject to change without notice
www.reed-sensor.com
30 August 2006
s
Reed Relays and Electronics India Limited  [email protected]  Tel 91-44-6528-4022
Restriction of Hazardous Substances
RoHS Compliance
In late 2002 the European Parliament approved two directives related to the reduction of electrical and electronic waste, namely
the Waste Electrical and Electronic Equipment (WEEE) and Restriction of the use of certain Hazardous Substances (RoHS)
Directives. The WEEE Directive aims to regulate the reuse, recycling and recovery of waste electrical and electronic equipment;
the ultimate goal is to prevent the disposal of this waste.
In the RoHS Directive, the use of the aforementioned substances in most electrical and electronic equipment will be banned or
severely restricted. The RoHS Directive calls for the elimination of these substances from most electronic equipment starting 1 July
2006. Our products are SGS certified for the RoHS compliant levels of Lead, Mercury, Cadmium and Hexalent Chromium.
End-of-Life Vehicle (ELV)
End-of-Life Vehicle (ELV) regulations set limits for the following substances:
Lead
Mercury
Cadmium
Hexavalent Chromium
Restriction of Hazardous Substances (RoHS)
The Reduction of Hazardous Substances (RoHS) regulations set limits for the following substances:
Lead
Mercury
Cadmium
Hexavalent Chromium
Polybrominated Biphenyls (PBB)
Polybrominated Diphenyl Ethers (PBDE)
To certify to the above compliances, these substances must not be intentionally added to the product AND cannot exceed the
following maximum allowable levels as a trace substance:
0.1% (1,000 ppm) for: Lead*, Mercury, Hexavalent Chromium, PBB and PBDE
0.01% (100 ppm) for: Cadmium
*Lead as an alloying element in copper alloys is allowed up to 4.0% (40,000 ppm); in steel up to 0.35% (3,500 ppm) is allowed; in
aluminum alloys up to 0.40% (4,000 ppm) is allowed. These requirements must be applied at the homogeneous material level.
Since RoHS compliance is a stricter standard than ELV compliance, parts that are RoHS compliant are also ELV compliant.
Due to continual improvement, specifications are subject to change without notice
www.reed-sensor.com
20 January 2009
s
Reed Relays and Electronics India Limited  [email protected]  Tel 91-44-6528-4022
Magnet Sensor Usage Notes
Magnet Sensors are delicate products. Handle with extra care.
Do’s
When switching inductive or capacitive loads, use contact protection circuits.
Don’ts
Do not use ferro-magnetic mounting parts, screws, or other ferro-magnetic devices nearby. This will affect the sensitivity (AT).
When manual soldering, do not subject to more than a 5 second dwell. This may cause damage to the seals, change sensitivity,
and reduce solderability.
Do not drop. Dropping or subjection to shock will permanently damage the contact or alter the sensitivity (AT).
Switching voltage, switching current, and contact rating should not exceed maximum limits stated in specification sheets.
Due to continual improvement, specifications are subject to change without notice
www.reed-sensor.com
26 May 2004
s
Reed Relays and Electronics India Limited  [email protected]  Tel 91-44-6528-4022